Paxton PROXIMITY LCD reader User Manual

11/01/2011
Ins-30091 PROXIMITY LCD reader
Technical Support
01273 811011 support@paxton.co.uk
Technical help is available: Monday - Friday from 07:00 - 19:00 (GMT)
Saturday from 09:00 - 13:00 (GMT)
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
Suitability
Security-sensitive doors
Paxton
Wet environments
Mounted on metal surface
The full colour backlit LCD screen can be congured to display images of the customer's choice. For example, an image using a company
name/logo could be used as the default display on each reader around the site.
The reader comes with four preloaded images. These can be replaced using a free uploader program available from our website via any
Net2Air USB bridge or a Net2Air USB dongle.
If you wish to update these images, you should ensure that you have a suitable Net2Air device as one is NOT supplied with the reader.
Readers mounted together
Fitting
The LCD display is best positioned at eye level for ease of reading.
It is mounted using the backplate and xings
provided and can be positioned to allow the display of portrait or landscape images.
300 mm
between readers
position of the orientation arrow (see diagram).
Make a hole in the wall to take the reader cable and
feed this through. Ensure there will be sufcient
slack to allow the reader to slide over the mounting plate during installation.
Present the reader to the mounting plate so that the slots pass over the side tabs in the plate.
Slide the reader down the plate until the retaining pin clicks into position.
A tool is provided with the reader to depress this pin should the reader ever need to be removed.
Image display
The unit comes with four preloaded images. These relate to the 3 LED's (Green, Amber and Red) on a standard Paxton reader plus a default image.
Once a token has been read, the control unit establishes the access permissions of that user. Access is granted or denied as appropriate with the designated image displayed. For example, if access is denied the image assigned could show "Please return to Reception".
Page 1
R
R
Wiring
Connection to a control unit
reader port
Connection modules
Reader junction box (325-020)
This module can be used to provide a connection point
for the reader RJ45 plug. The terminals on the module
are then wired colour for colour to the controller.
Alternatively, the reader can be wired directly into the screw terminals of the control unit by rst cutting off the RJ45 plug and stripping back the wires in the cable.
Further information on how to purchase Installer Tools is available at:
http://paxton.info/841
Reader port module (325-030)
This module may be purchased separately to speed up the installation and replacement of readers.
The reader port module is designed to convert the standard reader ports on Switch2 and Net2 controllers
to accept one or two RJ45 connections. Pull off the
screw terminal block from the reader port and simply replace it with this module.
Cable extensions
Readers can be extended using Belden CR9540 10-core overall screened cable to a maximum of 100 metres.
Page 2
Loading...