Paxton Proximity 375-110, Proximity 373-110, Proximity 345-220, Proximity 371-110, Proximity 372-110 Installation Manual

...
Paxton
ins-20600
Proximity readers and Keypads
1
2
1
1
3
Wiring
Installation guidelines
Readers should be mounted a minimum of 300mm/12” apart and not back to back.
All Proximity (P) and and keypad proximity (KP) readers should not be mounted on metal surfaces.
Screw connector option - The unit should be mounted in conjunction with an electrical backbox to achieve the required clearance for the connector. If an adaptor plate (310-750) is tted, the mountings on the backbox can also be used.
2
310-750-US
If a 75 series backbox adaptor kit (310-750-US) is tted, the mountings on a backbox can also be used.
Technical Help
1 - Readers/Keypads not working.
Software settings - Conrm that the settings of the reader or keypad are correct.
Connections - Check the wiring and integrity of the connectors. If possible, test this reader on the other port.
Extended cable - Belden 9538/9540 should be used up to a maximum of 500 feet. Twisted pair alarm cable should not be used. To conrm that an extended reader cable is not at fault, wire the reader directly to the port.
Supply voltage - Conrm that the voltage is within specication. (see table)
3