3
Wiring
Installation guidelines
• Readers should be mounted a minimum of 300mm/12” apart and
not back to back.
• All Proximity (P) and and keypad proximity (KP) readers should
not be mounted on metal surfaces.
• Screw connector option - The unit should be mounted in
conjunction with an electrical backbox to achieve the required
clearance for the connector. If an adaptor plate (310-750) is tted,
the mountings on the backbox can also be used.
2
310-750-US
If a 75 series backbox adaptor kit (310-750-US) is tted, the mountings
on a backbox can also be used.
Technical Help
1 - Readers/Keypads not working.
• Software settings - Conrm that the settings of the reader or
keypad are correct.
• Connections - Check the wiring and integrity of the connectors. If
possible, test this reader on the other port.
• Extended cable - Belden 9538/9540 should be used up to a
maximum of 500 feet. Twisted pair alarm cable should not be
used. To conrm that an extended reader cable is not at fault, wire
the reader directly to the port.
• Supply voltage - Conrm that the voltage is within specication.
(see table)