Small LED Signal Light
KHE
Colors Red, Amber, Green, Blue
IP23
IP55 when mount
rubber is used–sold
( )
separately
RoHS
UL
Specifications
Rated VoltageModel
KHE-24-R
KHE-24-Y
KHE-24-G
KHE-24-B
24V DC
100
φ
Consumption
Power
8.2W
10.1W
21.6W
When light is off
Clear globe specification
When flashing pattern
55 times±10 minutes
Globe
Polycarbonate resin with superb shock resistance and heat resistance
The KHE Series features a 100mm diameter, clear lenses to reduce false
indication, and 3 distinct signaling patterns including simulated rotation.
- Unique lens cut for enhanced visibility
from all angles
- 3 light pattern options: simulated rotation,
<IP55 compliant range when using mounting rubber>
strobe, flashing
- Rotating light option without a motor for longer product life
- Very low power consumption
· Available Colors: Red, Amber, Green, Blue
Number of flashes
simulated rotation
175 times±10 minutes
*Regarding the clear globe specification, size, price are the same for (-Z).
When strobe pattern
Double flash
75 times±10 minutes
Mass
0.45kg
6LJQDO7RZHU
6LJQDO/LJKW
5HYROYLQJ
:DUQLQJ/LJKW
Model Code
KHE-24-R-Z
Model
Rated Voltage
Dimensions (mm)
φ100
(90)
(146)
49
(11)
16
3-M5
24V DC24
(φ8)
From the cable slot (370)
Globe with color
Blank
Clear globe
Z
Colors
Red
R
Amber
Y
Green
G
Blue
B
Installation Dimension Drawings
Mounting Hole
3-φ6
120°
φ70
Cable slot
22.7
φ10
Nameplate Location
120°
5.4
Optional Parts
For details, see pages 182 to 187.
Optional Parts Model
Mount rubber
Wallmount Bracket
Wallmount Bracket
* When using a bracket for mounting on the wall-face, the IP value will still be 23, even when using
the mount rubber.
SZ-20 0
SZ- 007
SZ- 023
Wiring Diagram
Red
White
Gray
External Contact
Fuse
【Signal wire】
Voltage
Rated Current
Signal Wire
Power Supply Wire
Internally applied 24V DC
5mA
Strobe
Chase light
Flashing
Common
Power supply (non-polar)
Power supply (non-polar)
*Regarding the fuse, use a fuse that suits the rated value of the machine on which the product is mounted.
*Maximum 20A, 5μs in-flow current flow in the power line. Please use a power source with consideration to
capacity for this in-flow current.
Brown
Green
Amber
&XEH7RZHU
$XGLEOHV
+\EULG
'HYLFHV
6LJQDOLQJ
/('
,OOXPLQDWLRQ
2SWLRQV 1HWZRUN
104