PATLITE KJ-B, KJS-B, KES-B installation Guide

8. SPECIFICATIONS
1. Dimensions
Type KJ,KJB
غ116
3 lightsޓ395
2 lightsޓ290
1 lightޓ185
4-M6
16
2. Mounting Dimensions
Type KJ,KJB
Buzzer hole
غ74
35
Mounting hole
Wire entry hole
Name plate
3.Specifications
Type KJ,KJB
Style
1 light
2 lights
3 lights
4 lights
Bulb typeޓGlass G18ޓ Base BA15S (Spare bulb : 1)
Type KJB : Buzzer (Sound volume may be adjusted via the control on the bottom of the body.
Power supply wire (100V㨪240V AC only)
KJ(B)-102 KJ(B)-110 KJ(B)-112 KJ(B)-120 KJ(B)-124 KJ(B)-202 KJ(B)-210 KJ(B)-212 KJ(B)-220 KJ(B)-224 KJ(B)-302 KJ(B)-310 KJ(B)-312 KJ(B)-320 KJ(B)-324 KJ(B)-402 KJ(B)-410 KJ(B)-412 KJ(B)-420 KJ(B)-424
Lead wire
Type KJS,KJSB,KES,KESB
4 lightsޓ500
Type KJS,KJSB,KES,KESB
4-Ǿ
Rated voltage Rated current Flash per minute Bulb MassModel
24V DC
100V AC
110120V AC
220V AC 240V AC
24V DC
100V AC
110120V AC
220V AC 240V AC
24V DC
100V AC
110120V AC
220V AC 240V AC
24V DC
100V AC
110120V AC
220V AC 240V AC
Wire entry hole
Mounting hole
3-Ǿ5
Name plate
0.5A
0.1A
0.05A
1.0A
0.13A
0.07A
1.5A
0.18A
0.09A
2.0A
0.26A
0.13A
Wire typeޓ㧛ޓDia VCTޓ㧛ޓ0.75mm
VW-HTޓ㧛ޓ0.5mm
4-M4
120
130 flashes
par minute
130 flashes
par minute
130 flashes
par minute
130 flashes
par minute
غ82
120
2
2
2 lightsޓ256
1 lightޓ173
17
23
5
Buzzer hole
5
Ǿ70 (Ǿ50 Custom order item)
3 lightsޓ339
23
24V 10W
12V 5W
24V 10W
12V 5W
24V 10W
12V 5W
24V 10W
12V 5W
Lead wire Aprrox. 280mm Aprrox. 300mm
(Unit : mm)
(Unit : mm)
1.0Kg
1.2Kg
1.5Kg
2.0Kg
2.0Kg
2.5Kg
2.5Kg
3.0Kg
Type KJS,KJSB
Style
KJS(B)-101 KJS(B)-102
1 light
2 lights
3 lights
Bulb typeޓGlass G18ޓ Base BA15S (Spare bulb : 1)
Type KJSB : Buzzer
KJS(B)-110 KJS(B)-112 KJS(B)-120 KJS(B)-124 KJS(B)-201 KJS(B)-202 KJS(B)-210 KJS(B)-212 KJS(B)-220 KJS(B)-224 KJS(B)-301 KJS(B)-302 KJS(B)-310 KJS(B)-312 KJS(B)-320 KJS(B)-324
Power supply wire
Lead wire
Rated voltage Rated current Flashing cycle Bulb MassModel
12V DC 24V DC
100V AC
110120V AC
220V AC 240V AC
12V DC 24V DC
100V AC
110120V AC
220V AC 240V AC
12V DC 24V DC
100V AC
110120V AC
220V AC 240V AC
0.5A
0.06A
0.03A
1.0A
0.1A
0.05A
1.5A
0.2A
0.1A
Wire typeޓ㧛ޓDia
UL1007 AWG 20 UL1007 AWG 22
160 fashes par minute
160 fashes par minute
160 fashes par minute
12V 5W
24V 10W
12V 5W
12V 5W
24V 10W
12V 5W
12V 5W
24V 10W
12V 5W
Lead wire
Aprrox. 280mm
Type KES,KESB
Style
KES(B)-102
1 light
2 lights
3 lights
Power consumption will vary slightly according to color (red, amber and green).
Type KESB : Buzzer
Power supply wire
Specifications are subject to change without notice.
KES(B)-110 KES(B)-112 KES(B)-120 KES(B)-124 KES(B)-202 KES(B)-210 KES(B)-212 KES(B)-220 KES(B)-224 KES(B)-302 KES(B)-310 KES(B)-312 KES(B)-320 KES(B)-324
Lead wire
Rated voltage
24V DC
100V AC
110120V AC
220V AC 240V AC
24V DC
100V AC
110120V AC
220V AC 240V AC
24V DC
100V AC
110120V AC
220V AC 240V AC
Wire typeޓ㧛ޓDia
Power consumption
6W MAX
12W MAX
18W MAX
UL1007 AWG 20 UL1007 AWG 22
Flashing cycle MassModel
110 flashes
par minute
110 flashes
par minute
110 flashes
par minute
Lead wire
Aprrox. 280mm
Caution
٨
We are not in a position to be responsible for damage and trouble caused by handling against caution and warning described in this instruction manual.
0.5Kg
0.7Kg
0.8Kg
1.2Kg
1.2Kg
1.6Kg
0.4Kg
0.8Kg
1.0Kg
1.4Kg
1.4Kg
1.8Kg
2056-K
A95100060
FA001
INSTRUCTION MANUAL
= TYPE : KJ(B),KJS(B),KES(B)?
Thank you for specifying the for your application. Please read this manual before installing this system, and keep it carefully. In the case of maintenance, inspection and repair, please read this manual carefully. If you have question of this product, please feel free to contact us.
TO OPERATE THIS PRODUCT SAFELY, PLEASE OBSERVE THE FOLLOWINGS
NOTES TO BE OBSERVED FOR SAFE OPERATION
Note to be followed to prevent any damage to the user and other personnel or to assets are as follows:
عThe indications for warning are divided into the following classes according to the degree of danger ޓor damage incurred when the warning is not taken into consideration and the product is not correctly used.
=Warning?
=Caution?
This symbol marks important instructions that, if ignored or incorrectly followed, could conceivably lead to death or serious injury.
This symbol marks important instructions that, if ignored or incorrectly followed, could conceivably lead to injury or property damage.
Warning
Turn off the power supply before making wiring connections. Neglecting to so may cause shock.
Wiring should be careful enough there to be for no mistake. If wiring is mistaken,an internal be damaged and it will become the cause of a fire.
When the installation of this product requires the construction, please ask to specialist. Electric shock, fire and fall may occur.
When you use this product for security purpose, routine inspection must be done. Just emergency we recommend you to use this product together with other security
Do not use this product without lens or with cracked lens. It may cause electric shock.
Make sure power is turned off and the temperature of electric bulb falls down for repair to avoid electric shock and burn.
Make sure power is turned off when checking or changing a fuse or bulb to prevent danger shock.
Caution
Use only specified operating voltage. Excess voltage hastens degradation.
Make sure to set fuse in a power supply side, please connect a fuse.
To clean lens, head cover, and case, wipe with water or glass cleaner soaked soft cloth.
Do not use thinner or benzene as these cause color change or deform the surface. In an installation where there is violent vibration, the bulb life will be reduced. Observe the precautions:
Avoid mounting directly on equipment that vibrates or is subject to shock.
Avoid mounting on a pillar or wall in such a way that the unit would be subject to vibration. Use a mounting angle (stay) that is strong enough to support the rotating light against vibration.
Do not use the hands to rotate the reflector.
Do not oil the motor and rotor. (Neither will it rotate if oil enters the motor.)
1. PARTS NAME
Reflector
Bulb
LED type light source for KES(B)series.
Motor
Body
Name plate
Lot number indicated.
Lead wire
Type KJS(B)
Spare bulb
Attach it in the upper section
Type KJ(B) Spare bulb
Attach it in the upper section
Rubber packing
Power supply wire
an electric
circuit will
in case of
product.
of electric
following
wind and
Screw
Head cover
Lens
2056-K
'09.4.AUTO
LED unit
Type KESޔKESB only
Type KJB only

Buzzer volume controller
2. REPLACEMENT PARTS
The replacement parts are prepared. Please ask your local distributor for availability.
Lens (per type, per color) Reflector (per type) Bulb (per type, per voltage)
Head cover (per type)LED unit (per color, per voltage : Type KES(B) only)
If you have question please feel to contact us about other parts.
Rubber packing (per type) Motor (per type, per voltage)
Type KJ(B),KJS(B) only
3. TYPE NO. CONFIGURATION
㧷㧶㧮㧙غغغ㧙㧾㨅㧳
B Buzzer type
Light style
1 1 light style 2 2 lights style 3 3 lights style 4 4 lights style
Rated voltage
02 24V DC 10 100V AC 12 110120V AC 20 220V AC 24 240V AC
Lens color
R : Red Y : Amber G
: Green
B
: Blue
㧷㧶㧿㧮㧙غغغ㧙㧾㨅㧳
B Buzzer type
Light style
1 1 light style 2 2 lights style 3 3 lights style
Rated voltage
01 12V DC 02 24V DC 10 100V AC
110120V AC
12 20 220V AC 24 240V AC
Lens color
R : Red Y : Amber G : Green
㧷㧱㧿㧮㧙غغغ㧙㧾㨅㧳
B Buzzer type
Light style
1 1 light style 2 2 lights style 3 3 lights style
Rated voltage
02 24V DC 10 100V AC
110120V AC
12 20 220V AC 24 240V AC
4. HOW TO MOUNTING
Caution
٨
Cube tower must be installed in a vertical position where it has enough strength and less vibration. Do not install it horizontally or reversely.
٨
If the unit is to be installed in a high location, be sure to select a spot that affords easy service by maintenance personnel.
Drill the required mounting holes in the wall. (Refer to "8.SPECIFICATIONS" for the proper hole size.)
Use the accessory nuts to secure the unit.
For KJS(B) and KES(B) types: If the power and signal wires must be taken out to the side, snip the bottom of the body, as shown in the figure at right, and pull the lead wires through the new access.
For KJS(B) and KES(B) types: Refer to the mounting template provided for correct location of the holes.
5. HOW TO MAKE WIRING CONNECTION
Caution
٨
Turn off the power supply before making wiring connections. Neglecting to so may cause an electric shock.
٨
When you have questions for the method of special operation or plural units operation, we recommend you to ask our customer service before wiring.
٨
Do not pull lead wire and push it in body when wiring.
٨
Wiring should be careful enough there to be for no mistake. If wiring is misstaken,an
circuit will be damaged and it will become the cause of a fire.
internal
٨
During connection, refer to the wiring example. Be sure to use crimp type terminal connectors.
٨
Make sure to set fuse in a power supply side, please connect a fuse.
٨
Make sure of the specified operating voltage and current before use.
٨
Use only specified operating voltage. Excess voltage hastens degradation.
٨
Make sure not to use any other bulbs except ones described in specifications.
Type KJ(B)ޓ00V,120V,220V,240V AC Type KES(B)ޓAll modelޓޓ
()
Type KJS(B)ޓAll modelޓ
٨
Two or more units(100-240V)to be conducted parallel oparation,make sure to connect white and black power supply wire as shown below.
Lens color
R : Red Y : Amber G : Green
Body
Nippers or a similar tool
Snip off
1. Type KJ(B) 3. Type KJS(B),KES(B)
24V DC Type 100V AC,120V AC,220V AC,240V AC Type
ω
ω
4
3
2
1
This wiring diagram is for the four-light unit. The number of signal wires will vary for other number of lights. (Refer to Table 1.) The type with a buzzer (KJB, as shown) is wired to sound the buzzers in conjunction with their respective rotating lights. If the buzzer must sound independently (not in conjunction with the rotating lights), independently wire a switch to the buzzer's signal wire (any one of the gray wires). Be sure that the ends of all unused wires are insulated.
The lamps are numbered 1,2,3,etc., starting with the bottom unit.
Be sure to install a fuse on the power supply end.
Refer to Table 2 for the selection of a contact capacity sufficient to handle the initial current, or use a relay as required.
Table 1]
4
3
2
1
Table 2?
For rotating light signal wire 50V,5A
4
3 2
1 Buzzer
Buzzer
Buzzer COM
1 Light(12V, 24V type only)
Type KJB
only
)
Red
Red
Yellow
Green
Blue Gray Gray Gray
White
Outer contact
3
2
Fuse(10A)
1
+
-
Power supply
( 24V DC )
Lead wire colorType KJKJB
Red
Yellow
2 Lights
Normal current
450mA
44
3 2
1 Buzzer
Buzzer
Buzzer COM
Red Yellow
Yellow
Green Blue
3 Lights
Initial current
4.5A
0.3A30mAFor Buzzer signal wire 50V,1A
Type KJB
only
)
Red
Yellow
Green
Blue Gray Gray Gray
White
Black
White
Outer contact
Power supply
100V AC 120V AC 220V AC
Fuse(3A)
()
240V AC
Red
Green
4 Lights
Contact capacity
2. Type KJS(B),KES(B)
ω
3
2
1
3 2
1 Buzzer
Buzzer
Buzzer COM
Type KJSB,KESB
)
only
Red
Yellow
Blue Gray Gray Gray
Brown
Black
White
Outer contact
Fuse(5A)
Power supply
12V DC 24V DC
-
100V AC 120V AC
+
()
220V AC 240V AC
As for a KES(B) type, this use cannot 12V model.
Wiring should be made as follows in case of using transisitor as other contact.
3
2
1
Use a small-current, no-voltage contact (twin contacts recommended) or an open-collector transistor.
Absolutely do not connect direct power in a signal wire, damage the internal circuit.
3 2
1 Buzzer
Type KJSB,KESB
Buzzer
)
Buzzer COM
TYPE
Withstand voltage
Current capacity
only
5. MAINTENANCE
1. Change Lens
Please follow the procedure mentioned below to change the lens.
Ԙ
Make sure power is turned off when changing lens.
ԙ
Loosen head cover screw,then put the lens off.
Ԛ
Put in the new lens,then installing head cover.ޓ
Be sure to reinstall the rubber paking to the b globe and head cover (one size for all applications), the unit will no longer be splash proof.
2. Change Bulb [ Type KJ(B),KJS(B) ]
Please follow the procedure mentioned below to change the bulb.
Ԙ
Make sure power is turned off when changing bulb.
ԙ
Remove lens.(Refer to the "Change Lens" instruction mentioned above.)ޓ
Ԛ
The bulb can be easily removed by pressing it downward to turn to left.
ԛ
The new bulb can be easily installed by pressing it downword to turn to right.
Ԝ
Put in the lens, then installing head cover.
Make sure not to use any other bulbs except ones described in specifications.ޓ
If you have any questions of the product, please feel free to contact us.
7.
BEFORE REQUESTING SERVICE
Please check the list shown below before requesting repairs. If the product still
not work, please contact us for repairs.
This wiring diagram is for the three-light unit. The number of signal wires will vary for other number of lights. (Refer to Table 1.) The type with a buzzer (KJSB, KESB, as shown) is wired to sound the buzzers in conjunction with their respective rotating lights. If the buzzer must sound independently (not in conjunction with the rotating lights), independently wire a switch to the buzzer's signal wire (any one of the gray wires). Be sure that the ends of all unused wires are insulated.
The lamps are numbered 1,2,3,etc., starting with the bottom unit.
The power wires for the AC 100,120,220,240-volt version are not polarized + or - .
Be sure to install a fuse on the power supply end.
Use a switch contact capacity of at least 50 mA for the lamp and not less than 300 mA for the
Table 1]
3
2
1
Lead wire colorType KJSKJSB,KES,KESB
Yellow
Blue
1 Light
Blue
2 Lights
Red
Yellow
Blue
3 Lights
buzzers.
ޓPlease feel free to contact our sales office with any questions
The reflector would not rotate and the lamp stays turned off.
The reflector rotates but the lamp is off
The lamp is turned on but the reflector stays stopped.
The buzzer dose not work.
Please note that any malfunction or damage resulting from modification by the customer will not be covered under the warranty.
Problems
Red
Yellow
Blue Gray Gray Gray
Brown
Black
White
NPN Transistor
(2SC or 2SD)
Where to check What to do
Is the power on?
Is the light bulb burned out?
Is the motor stopped? Is the motor lubricated?
Is the power polarity opposite on the DC 12 or 24 volt version?
Power supply
12V DC 24V DC
-
100V AC 120V AC
+
()
220V AC 240V AC
Vcޓ㧪ޓ45V or up
Icޓ㧪ޓ300mA or upBuzzer
Icޓ㧪ޓ50mA or upRotating light
Slide to downward
ody
or
for installation.
Turn to right (Install)
As for a KES(B) type, this use cannot 12V model.
NON-Contact relay
for DC load only
Pushing downward
concerning the product.
Check the power wiring, plug connection and fuse.
If a switch is installed, check to see that it is turned on.
If it is, replace it with a new one.
The motor is broken or has reached the end of its life. Request a repair.
Check and correct the polarity.

Remove screw
Slide to upward for remove lens
Turn to left (Remove)
2056-K