EDLM EDWM/
Explosion-Safe Signal Tower
Wall Mount
ATEX&FM
CENELECStandards
Testing Authority
NEC Article 505
EDLM/EDWM
Explosion-Safe
LED
IP66
NPN/PNP
Open-collector
EDWM
FEATURES
• Complies with with CE according to ATEX and NEC 505 standards.
• Mounting can be done in the Upright, Wall-mount, and Horizontal position
• Voltages available in AC/DC24V, AC120V, AC230V, and free voltage of AC90 -250V
• Easy wire connection terminals to the Signal Tower by opening the bottom
• Di erent lens colors available for customized designs
• Available in 3 Tier or 5 Tier Stacks
• Ingress protection of IP66
EDLM
Innovative maintenance-free Explosion-safe LED Signal Towers
Horizontal Mount
Direct Mount
with pressure and ame-proof housing, ideal for potentially
ammable and hazardously explosive environments.
■CENELEC (ATEX Directive)
Type EDLM-302FE EDLM-312FE EDLM-323FE EDWM-502FE EDWM-5M2FE
Rated Voltage AC/DC24V AC 120V AC 230V AC/DC 24V AC 90V - 250V
Signal Line Current (Per LED) Red/Amber: 52.5mA Green: 20.0mA Red: 22.6mA Amber: 26.6mA Green: 17.5mA Blue/White: 38.9mA
Explosion Protection Ratings
Operating Temperature Range -20
Operating Humidity Range 45% - 85% RH (No dew or condensation)
Ambient Pressure Range 80 - 110kpa
Lighting Pattern Flashing (60 ±12 ashes per minute) / Continuous Lighting
Protection rating IP66
Vibration Reistance 9.8m/s
Mounting Outdoor & Indoor: Upright Outdoor & Indoor: Upright and Sideways
Luminosity Red: 350mcd Amber: 580mcd Green: 1300mcd Red/ Amber/ Green: 1000mcd Blue/White: 300mcd
Mass (Main Body) 4.3kg 4.7kg
Material
■CENELEC (ATEX Directive)
Type EDLM-302FA EDLM-312FA EDLM-323FA EDWM-502FA EDWM-5M2FA
Rated Voltage AC/DC24V AC 120V AC 230V AC/DC 24V AC 90V - 250V
Signal Line Current (Per LED) Red/Amber: 52.5mA Green: 20.0mA Red: 22.6mA Amber: 26.6mA Green: 17.5mA Blue/White: 38.9mA
Explosion Protection Ratings
Operating Temperature Range -20
Operating Humidity Range 45% - 85% RH (No dew or condensation)
Ambient Pressure Range 80 - 110kpa
Lighting Pattern Flashing (60 ±12 ashes per minute) / Continuous Lighting
Protection rating IP66
Vibration Reistance 9.8m/s
Mounting Outdoor & Indoor: Upright Outdoor & Indoor: Upright and Sideways
Luminosity Red: 350mcd Amber: 580mcd Green: 1300mcd Red/ Amber/ Green: 1000mcd Blue/White: 300mcd
Mass (Main Body) 4.3kg 4.7kg
Material
48
II2G Ex d IIC T6 (Zone 1,2) II2D EX tD A21 IP66 T800C (Zone 21, 22)
Upper/Lower Housing: Aluminum Alloy (Melamine Baked Finish)
Fitting Bracket: Stainless Steel (SUS316)
II2G Ex d IIC T6 (Zone 1,2) II2D EX tD A21 IP66 T800C (Zone 21, 22)
Upper/Lower Housing: Aluminum Alloy (Melamine Baked Finish)
Fitting Bracket: Stainless Steel (SUS316)
0
C - +500C (no ice)
2
Glass Case: Borosilicate Glass
Cable Gland: Brass
0
C - +500C (no ice)
2
Glass Case: Borosilicate Glass
Cable Gland: Brass
EDLM & EDWM are covered by the speci cations shown in the
Common Standards for Europe
The ATEX directive is a CENELEC Standard
•
shaded
areas below:
Classi cation Standard PATLITE Models Constant Exposure Occasional Exposure Rare & Temporary
ATEX, IEC/EU
Directive 94/9/EC
Common Standards for the USA
IEC 60079-10
EN 60079-10
EDLM, EDWM Zone 0 Zone 1 Zone 2
NEC is a National Electrical Code Standard for North America
•
Classi cation Standard PATLITE Models Constant Exposure Occasional Exposure Rare & Temporary
NEC Article 505 ANSI/NFPA 71 EDLM, EDWM Zone 0 Zone 1 Zone 2
NEC Article 500 ANSI/NFPA 70 — Division 1 Division 2
Dimensions
EDLM/EDWM
38 90
12335
347
12
Wiring
ȭ120
140
ȭ
Use for ATEX Directive.
Fitting Bracket
Upper Case
Indicator
Glass Case
Lower Case
Lead-in Port 1
3/4 NPT
(48)
Earth Terminal
M4 Screw
Cable Gland
■Installation
(Wall-mount)
56
(Horizonal-mount)
218
ڦ Cable Gland*
3/4 NPT
(31)
(24)
*ATEX Model ... Included
347
*NEC Model ...... Not Included
ڦ Flush-mount Bracket
9
15
92
56
φ
56
50
11
φ9
φ
φ
38
50
11
9
4
15
9
56
(Unit: mm)
126
O-ring
152
283
56
(100)
(86)
ȭ4.4
(415)
Lead-in Port 2
3/4 NPT
5
218
㸦㸧
Plug
Cover
Terminal Block
Set Screw
EDLM (3 Color LED) EDWM (5 Color LED)
•
EDLM-302FE/ EDLM-302FA
<Hazardous Area >
Main Body Casing
Green
Brown
Gray
Yellow
2
PWR Wire
PWR Wire
Flashing COM
LED Green
LED Amber
LED Red
Red
Orange
LRLYLGFCV1V
•
EDLM-312FE/ EDLM-312FA
EDLM-323FE/ EDLM-323FA
<Hazardous Area >
Main Body Casing
Red
Orange
Green
Yellow
Brown
Gray
※Green / Yellow
LRLYLGCCFCV1V
※120,230-240V Only
Black
2
PWR Wire
PWR Wire
Flashing COM
Continuous COM
LED Green
LED Amber
LED Red
<Non-hazardous Area >
External Protection Fuse
㸯㸿
Continuous light
Outer Contacts
Flashing
Outer Contacts
<Non-hazardous Area >
External Protection Fuse
1A
Power
Source
Continuous light
Outer Contacts
Flashing
Outer Contacts
Power
Source
•
EDWM-502FE/ EDWM-502FA
<Hazardous Area >
Main Body Casing
<Non-hazardous Area >
Green
Yellow
Blue
White
Brown
Gray
External Protection Fuse
㸯㸿
Continuous light
Outer Contacts
Flashing
Outer Contacts
<Non-hazardous Area >
External Protection Fuse
1A
Continuous light
Outer Contacts
Flashing
Outer Contacts
Power
Source
Power
Source
2
PWR Wire
PWR Wire
Flashing COM
LED White
LED Blue
LED Green
LED Amber
LED Red
Gray
Black
Blue
White
Yellow
Brown
FCV1V
2
C
PWR Wire
PWR Wire
Flashing COM
Continuous COM
LED White
LED Blue
LED Green
LED Amber
LED Red
Red
Orange
Green
LRLYLGLBLWFCV1V
•
EDWM-5M2FE/ EDWM-5M2FA
<Hazardous Area >
Main Body Casing
Red
Orange
Green / Yellow
※
LRLYLGLBLWC
External Protection Fuse (All Models): 250V 1A
49