This Installation Guide is intended to walk you through a typical installation. In
preparing the User Guide, it has been assumed that you are reasonably
familiar with the DMX512 and the various wiring methods associated with
RS422/485 based protocols.
DMXPathfinder MR is a DMX512 distribution tool, providing a method for
distributing up to eight DMX sources (such as dimming or moving light
controls) to a number of DMX devices or outlets. All inputs and outputs are
opto-isolated and repeated, in conformance with the USITT/ESTA
specifications for DMX512 signal distribution.
The Installer’s Guide is divided into 2 chapters:
• DMXPathfinder Installation leads you through all the steps necessary
for a “clean” installation of your hardware.
• Maintenance and Testing offers troubleshooting tips and procedures
to keep everything running smoothly.
2
DMXPathfinderLR Installation & Assembly
Chapter 1: Installation and Assembly
SUMMARY
This section describes how to correctly assemble the DMXPathfinder MR
hardware into an equipment rack and connect permanently installed external
wiring.
To ensure a trouble-free installation, you should follow this sequence:
1. Install the equipment rack
2. Run conduit and pull cable
3. Install auxiliary rack equipment and power bars
4. Mount termination boards (if applicable)
5. Dress cable in the rack and terminate (if possible)
6. Unpack the DMXPathfinder MR I/O Modules and prepare
7. Install the I/O Modules in the rack
8. Connect cabling to the I/O Modules
9. Power up and test
BEFORE STARTING
Before installing the DMXPathfinder MR equipment rack, you should carefully
consider the environment in which the equipment is to be installed, the
proximity to power sources, and the required conduit and/or cable runs.
Environmental Considerations -- To maximize equipment life and minimize
the possibility of unreliable operation or failures, the following conditions
should be adhered to:
• Ambient temperature extremes: -10 to 50 degrees C
• Recommended operating temperature: +10 to +40 degrees C
• Relative humidity: 10-95% non-condensing
• General conditions: clean, dust-free environment
Fan Cooling -- Each of the DMXPathfinder MR Output Modules is provided
with an internal cooling fan. These fans draw air in on the right hand side
and exhaust air on the left. To ensure adequate air circulation, do not block
the modules at either side. If more than two or three Output Modules are
installed in the same rack, allow for at least a 1U ventilation panel at the top
and bottom of the rack.
XPUXPUXPUI/O OPTO-REPEATER UNI TSI/O OPTO-REPEATER UNI TSI/O OPTO-REPEATER UNI TS
Isolated Power
Talkbac k D a ta
Transmit Data
1
2
Isolated Power
Talkbac k D a ta
Transmit Data
9
10
Isolated Power
Talkbac k D a ta
Transmit Data
17
18
Isolated Power
Talkbac k D a ta
Transmit Data
25
26
Main 5V Status
Merge Enabled
Crosspoint OK
Isolated Power
Talkbac k D a ta
Transmit Data
1
2
Isolated Power
Talkbac k D a ta
Transmit Data
9
10
Isolated Power
Talkbac k D a ta
Transmit Data
17
18
Isolated Power
Talkbac k D a ta
Transmit Data
25
26
Main 5V Status
Merge Enabled
Crosspoint OK
12
19
20
27
28
3
4
11
12
19
20
27
28
3
4
11
12
19
20
27
28
6
13
14
21
22
29
30
5
6
13
14
21
22
29
30
5
6
13
14
21
22
29
30
SYSTEM
RESET
7
8
15
23
31
7
15
23
31
7
15
23
31
B
16
C
24
D
32
8
B
16
C
24
D
32
8
B
16
C
24
D
32
(inputs 1 - 8)
Output Module #1
(outputs 1 - 32)
Output Module #2
(outputs 33 - 64)
Output Module #3
(outputs 65 - 96)
Input Module
19" Rack
Power Requirements -- A single-phase power source (50 or 60Hz, 100240VAC, at 0.2A per Input Module and 0.5A per Output Module) must be
provided to the DMXPathfinder MR equipment rack. It is recommended that
no more than ten I/O modules be connected to one power circuit due to the
startup current requirements of their switch-mode power supplies.