Pathway LCDM12 User Manual

LCDM12 DEMULTIPLEXER Configuration
CONNECTOR LEGEND
S/N
SERIAL#
4.7500"
CONNECTOR J 1
V+ COM
CD-
12VDC @ 250mA Power Supply and Signal Common
4.5000"
LCDM12 DECODER REV.0 9940
0.2500"
0.2500"
3.7250"
4.1250"
LED INDICATORS
Two LEDs are used to indicate power supply and proc es s or run status and data receive detection.
Glowing steadily indicates power supply and processor
RUN
OK; off indicates no power, and flashing indicates defective processor hardware.
Glowing steadily indicates data signal received; off
RxD
indicates no signal present. Note that an address selection out of the range of the data signal will extinguish the LED.
OUTPUT CONFIGURATION
CAUTION – Disconnect power from the unit before making any changes
For 4-12V output, JP2 is installed. For 12-15V output, JP2 is removed. JP1 is for factory use only and should not be installed.
CD+
Signal Input USITT DMX512/AMX192 Data/Clock True
CONNECTOR J 2
PIN
1-12 13 & 14
Analog Control Outputs Low-level 0 - +2v High-level +7 - +15V Max. Drive 10mA
CONNECTOR J 3
Aux. Control Outputs on 14 pin DIL header Channels 1 to 12
Signal Common
ADDRESS SELECTION
Three rotary switches select the offset start address for the unit in most configurations. In test mode, the switches set dimmers to full one at a time. The switches are set as (S4) hundreds, (S3) tens and (S2) ones.
DIP Switch Settings
STATUS QUO HOLD TIME
Disabled (2 Sec. timeout) OFF Enabled ( 5 Min. timeout) ON
Maintains last dimmer levels for set time on loss of input data signal
TEST AND CALIBRATE MODE
Disabled (Normal Operation) Enabled ON
When enabled allows analog dimmer outputs to be brought to full one at a time a s selected by the rotary address switches.
FUTURE USE
S1-1
S1-2
OFF
S1-3
DMX TERMINATION
OUTPUT VOLTAGE ADJUSTMENT
Place the unit in test mode (S1-2 on) and set the address switches to 000 or 001. Ensure that t he decoder is connected to dimmer no. 1 and JP3 is in the correct position. Connect a DC voltmeter between COM and output terminal no. 1 on the circuit board. Adjust P1 to achieve the desired high-level full on control voltage, and adjust P2 for the low-level full off voltage.
DMX Line Unterminated OFF DMX Line Terminated ON
This switch connects a 100-ohm resistor across the DMX data pair. The unit should be terminated if it is the last receiving device on the DMX line.
NOTE: The LCDM12 is factory preset for low-level 0V, high-level 10V output
Pathway Connectivity Inc., 480C - 36 Avenue S.E., Calgary, AB, T2G 1W4 Canada tel (403) 243-8110 fax (403) 287-1281
Rev.0 ver2.2 release 4
support@pathwayconnect.com
www.pathwayconnect.com
Printed in Canada
S1-4
06/03
Loading...