Parker Hannifin EC106 User Manual

Bulletin HY11-5715-558/UK
Power Amplifier for Pressure-/Flow Valves
Installation Manual Series EC106
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division Gutenbergstr. 38 41564 Kaarst, Germany Tel.: +49-181 99 44 43 0 Fax: +49-2131-513-230 E-mail: infohcd@parker.com Copyright © 2002, Parker Hannifin GmbH & Co. KG
IA EC106 UK.INDD RH 02.06
Power Amplifier f. Pressure-/Flow Valves
Series EC106Installation Manual
2
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Note
This document and other information from Parker Hannifin GmbH, its subsidiaries, sales offices and authorized distributors provide product or system options for further investigation by users having technical expertise. Before you select or use any product or system it is important that you analyse all aspects of your application and review the information concerning the product or system in the current product catalogue. Due to the variety of operating conditions and applications for these products or systems, the user, through his own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance and safety requirements of the application are met. The products are subject to change by Parker Hannifin GmbH at any time without notice.
Power Amplifier f. Pressure-/Flow Valves
Series EC106Installation Manual
IA EC106 UK.INDD RH 02.06
3
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Design
Series
Module Type
Amplifier,
switchable, pressure-/flow valves, Ramps
Electronic Module
for Pressure-/ Flow
Valves
DSA, DWE, DWU
RE*W, TDA*LAF,
TEA*LAF
Number of
Channels
Electronic module for the control of proportional pressure or flow valves. The pressure-/ flow values are given by externally supplied command signals and internal ramp potentiometers.
Features
• Processing and amplification of externally sup­plied positive commands into output signals for the control solenoid.
• Up to 6 independent channels for the control of up to 6 valves.
• Each channel is equipped with a slide switch for selection of pressure or flow valve operation.
• Ramp function
• Pulsed low loss amplifier power stages with supporting constant current control for constant, temperature independent solenoid forces.
• Dither generator with applied frequency to improve static characteristics.
Ordering Code
Design 2 channels 4 channels 6 channels Supply voltage
[V]
24 ±10%
Power consumption max.
[VA]
70 125 190
Command voltage
[VDC]
0...+10
Reference output
[VDC]
10 ±5% / max. 100mA
Solenoid output current, max.
[A]
2 x 1.3 4 x 1.3 6 x 1.3
Ramps
[s]
0.01...10
Ambient temperature
[°C]
0...+70 Connection 48pole male connector, DIN 41612F Cable connection Supply connections + valve: AWG15; command inputs AWG20 Fuse DIN 41571 4A medium lag 6.3A medium lag 10A medium lag
Characteristics
EC 106
Code Quantity
02 2 04 4 06 6
IA EC106 UK.INDD RH 02.06
Power Amplifier f. Pressure-/Flow Valves
Series EC106Installation Manual
4
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Block Diagram (2 Channel Option)
EMC
EN 50081-2 EN 55011
EN 50082-2 ENV 50140 EN 61000-4-4 ENV 50204 EN 61000-4-5 EN 61000-4-2 EN 61000-4-6
Power Amplifier f. Pressure-/Flow Valves
Series EC106Installation Manual
IA EC106 UK.INDD RH 02.06
5
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Block Diagram (4 Channel Option)
IA EC106 UK.INDD RH 02.06
Power Amplifier f. Pressure-/Flow Valves
Series EC106Installation Manual
6
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Block Diagram (6 Channel Option)
Power Amplifier f. Pressure-/Flow Valves
Series EC106Installation Manual
IA EC106 UK.INDD RH 02.06
7
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Operating and Diagnostic Elements (Elevation A)
z2 0V Supply z4 0V Command 1 z6 0V Supply z8 0V Command 2 z10 0V Supply z12 0V Command 3 z14 0V Command 4
z18 0V Command 5 z20 0V Supply z22 0V Command 6 z24 0V Reference output z26 0V Reference output
z30 Input 24VDC supply z32 Input 24VDC supply
Connector (Elevation B)
d2 Output solenoid 1
d6 Output solenoid 2
d10 Output solenoid 3
d16 Output solenoid 4
d20 Output solenoid 5
d26 Output solenoid 6
d30 Output +10V reference d32 Input 24VDC supply
b2 Output solenoid 1 b4 Input command 1 / 0...+10V b6 Output solenoid 2 b8 Input command 2 / 0...+10V b10 Output solenoid 3 b12 Input command 3 / 0...+10V b14 Input command 4 / 0...+10V b16 Output solenoid 4 b18 Input command 5 / 0...+10V b20 Output solenoid 5 b22 Input command 6 / 0...+10V
b26 Output solenoid 6
b30 Output +10V reference b32 Input 24VDC supply
Notes:
Turn off the electrical power to the board whenever removing it from the card holder.
Black grip strip
1 Ramp potentiometer channel 1
2 Switch p/Q channel 1
3 Ramp potentiometer channel 2
4 Switch p/Q channel 2
5 Ramp potentiometer channel 3
6 Switch p/Q channel 3
7 Ramp potentiometer channel 4
8 Switch p/Q channel 4
9 Ramp potentiometer channel 5
10 Switch p/Q channel 5
11 Ramp potentiometer channel 6
12 Switch p/Q channel 6
IA EC106 UK.INDD RH 02.06
Power Amplifier f. Pressure-/Flow Valves
Series EC106Installation Manual
8
Parker Hannifin GmbH & Co. KG
Hydraulic Controls Division
Dimensions (Euro card)
Installation guide to electronic modules to provi­sion of electromagnetic compatibility
Power Supply
The utilized power supply has to comply with the EMC-standards. Relais and solenoids operating from the same supply circuit as the valve electronics have to be fitted by surge protection elements.
Wiring Cable
The wires between the installation site of the module and the peripheral units, as power supply, valve sole­noids, command signal source have to be shielded. The following wire sizes must be reached: power supply and solenoids AWG 15, other connections AWG 20. The capacity should not exceed a value of approx. 130 pF/m (wire/wire). The maximum cable length is 50 m. No power current lines may be placed within the wired shielded cables to the electronic module. The cable shield has to be connected to ground at both ends (see also chapter “Grounding“). Please be aware of ground loops.
Installation
The module has to be mounted within a conductive, shielded enclosure. Usable is i.e. an EMC-approved control cabinet. A perfect grounding of the enclosure is mandatory (see also chapter “Grounding“).
Grounding
The mounting plate of the valve has to be connected to the grounded metal machine frame. The cable shields must be tied to ground at the control cabinet. A low-ohmic potential compen-sation wire has to be provided between the control cabinet and the machine frame (cable wire >AWG 7 cross section) to prevent ground loops.
Loading...