Paradyne 8820 User Manual

8820 Broadband Access Concentrator AC to DC Power Supply
Installation Instructions
Document Number 8800-A2-GZ41-20
June 2004

AC to DC Power Supply

The AC to DC Power Supply consists of a power supply chassis and one or two power modules.
The power supply chassis with one power module is Feature
Number 8800-F2-900.
The power module is Feature Number 8800-F2-901.
The AC to DC Power Supply can be used to supply redundant power to a single 8820 Broadband Access Concentrator (BAC), or non-redundant power to one or two BACs.
The maximum DC output of each power module is 825 watts. Do not exceed 825 watts in your BAC configuration.

Product-Related Documents

Complete documentation for Paradyne products is available at www.paradyne.com. Select Support Technical Manuals.
Document Number Document Title
8820-A2-GN20 8820 Broadband Access Concentrator Installation Guide
To request a paper copy of a Paradyne document, or to speak with a sales representative, please call 1-727-530-2000.
8800-A2-GZ41-20 June 2004 1

Installation Overview

Installation of the AC to DC Power Supply requires the following steps:
1. Mount the power supply in your rack.
2. Connect the power supply to the 8820 BAC.
3. Connect the power supply to an AC power source.
Be sure to register your warranty at www.paradyne.com/warranty.

Mounting the Power Supply

Procedure
To mount the power supply:
1. Remove the power modules from the power supply chassis.
2. The power supply is shipped with its mounting brackets set up for a 19-inch rack. If you are installing the power supply in a 23-inch rack, remove the mounting brackets from the power supply chassis, turn them, and reinstall them with their short sides against the body of the power supply chassis.
3. Determine where the power supply will be placed in the rack. The power supply should be placed under the BAC or BACs it will supply power to.
4. If the rails of your rack have unthreaded screw holes, install self-retaining nuts on the rails where the mounting brackets will be fastened.
5. Line up the mounting brackets with the front rail holes.
6. Loosely install the bottom screws first and then the top screws.
7. Tighten all screws firmly with a Phillips screwdriver.
8. Replace the power modules removed in Step 1.
2 June 2004 8800-A2-GZ41-20

Connecting the Power Supply to the BAC

Power Entry Modules (PEMs) installed in the front of the BAC provide –48 VDC power distribution, a 35-amp circuit breaker, power line filtering and input power monitoring. They are designated PEM A (on the left) and PEM B (on the right). All input power is distributed to the system via the PEMs, so that if one PEM or one power source fails, power will be supplied through the other PEM automatically without service interruption. Power inputs may be connected to the PEMs at the front of the BAC using the PEM’s terminal blocks, or at the terminal block on the back of the BAC. This document shows the recommended technique, with connections at the rear of the BAC. See the 8820 Broadband Access Concentrator
Installation Guide for more information.
P O
W E
R E
N T
R Y
M
O D
U L
E L E
F T
U N
IT : L
I
N R IG
H T
U N
IT :
L
I
48V RTN
W A
RN
IN G
!
POWER MUST BE DISCONNECTED AT THE SOURCE
BEFORE REMOVING OR INSTALLING THIS PWR ENTRY MODULE
E A N E
B
P O
W E
R L E
F
T R I G
H
T
48V NEG
48V RTN
W A
R N
IN G!
POWER MUST BE DISCONNECTED AT THE SOURCE
BEFORE REMOVING OR INSTALLING THIS PWR ENTRY MODULE
C
L O
C
K
S
E
R
E N
IA
T R
L
Y M
O D
A
U L
C
E
A
U
N
M
IT
:
C
L
IN
C
E
A
A
L A
R
M
L A
N
2
/W
U
N IT
: L
IN E
B
48V NEG
B
C
L O
C
K
A
N
S
4
L
O
T
6
8
A
1 0
1 2
1 4
1 6
1
S
E
R
IA
L
A
L A
R
M
1
35
S
M
C
M
8
7
9
B
1 1
1 3
1 5
1 7
PEM
A
PEM
B
48V RTN
PEM Circuit
POWER ENTRY MODULE
LEFT UNIT: LINE A
RIGHT UNIT: LINE B
O
48V NEG
Breaker
POWER MUST BE DISCONNECTED AT THE SOURCE
WARNING!
BEFORE REMOVING OR INSTALLING THIS PWR ENTRY MODULE
00-15326a-02
Review the following procedures and determine which is appropriate for your configuration. The recommended configuration is two power modules connected to one BAC (providing a redundant power source). For all configurations:
Make sure that the AC power cords are not connected to the power supply
until other wiring is completed.
Use 8 AWG solid or stranded wire.
Attach ring tongue terminals to the ends of the wires to be connected to the
BAC power terminal block. See the 8820 Broadband Access Concentrator
Installation Guide for more information.
Attach ring tongue terminals to the ends of the wires to be connected to the
power supply.
Strip 1/2 inch of insulation from the ends of the wires to be fastened at split
bolt connectors or the grounding lug of the BAC.
CAUTION:
The following procedures must be performed by a trained technician.
8800-A2-GZ41-20 June 2004 3