Hotwire 7986 M/HDSL Standalone Termination Unit
with G.703 Interface
Installation Instructions
Document Number 7986-A2-GZ40-00
March 1999
Product Documentation on the World Wide Web
We provide complete product documentation online. This lets you search the
documentation for specific topics and print only what you need, reducing the
waste of surplus printing. It also helps us maintain competitive prices for our
products.
Complete documentation for this product is available at www.paradyne.com.
Select
Hotwire 7986 M/HDSL Standalone Termination Unit, with G.703 Interface,
User’s Guide
To request a paper copy of a Paradyne document:
Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396)
Outside the U.S.A., call 1-727-530-8623
Installation Overview
Installation and configuration of the Hotwire 7986 Standalone Termination Unit
consists of:
Connecting power to the unit.
Connecting to the network.
Connecting to a DTE.
Connecting a system terminal.
Providing initial unit identity information or changing existing identity
information.
Configuring your unit using internal switchpacks or using the Configuration
Edit menus.
Before you install the Hotwire 7986 Standalone Termination Unit, read the
Important Safety Instructions
Be sure to register your warranty at www.paradyne.com. Select
Support → Warranty Registration.
on page 20.
Service &
7986-A2-GZ40-00
March 1999
1
Connecting Power to the Unit
If your package includes a power pack:
Plug the power pack into an ac outlet
having a nominal voltage rating between 100–240 Vac. Connect the output cable
of the power pack to the connector marked POWER on the rear panel.
If your package includes a direct-connection +24 Vdc power cable:
unit to an external +24 Vdc SELV (Safety Extra Low Voltage) power source as
described in
If you will use a –48 Vdc power supply:
Connecting the Unit to an Optional External +24 Vdc Power Source
Connect the unit to an external –48 Vdc
SELV power source as described in the documentation shipped with the power
supply and power cable.
Connecting the Unit to an Optional External +24 Vdc Power Source
Using the dc power cable, the Hotwire 7986 Standalone Termination Unit is
capable of operating on a +24 Vdc SELV power supply.
Procedure
To use the dc power cable:
1. Connect the green wire to a suitable ground.
2. Connect the orange wire to the +24 Vdc source.
3. Connect the white wire to the return.
4. Cut the black, red, and blue wires off at the outer insulation.
5. Plug the power connector into the 7986 Standalone Termination Unit.
Connect the
.
2
1
2
3
4
5
6
Black
Red
Green
White
Orange
Blue
+24 Vdc Power Supply Pinouts
March 1999
X
X
Ground
RTN
+24 Vdc
X
99-14158-02
7986-A2-GZ40-00
Connecting to the Network
Procedure
To connect your unit to the network:
1. Connect one end of the supplied network cable into the rear panel DSL jack.
2. Connect the other end to your DSL network interface.
NOTE:
Do
not
use a flat VF network cable as this may severely degrade the
performance of the termination unit. Use only Cat 5 twisted-pair network
cable.
A crossover cable (Pins 1 and 2 to 4 and 5) is required to connect two
7986 Standalone Termination Units back-to-back.
Connecting to a DTE
The E1 network interface is either two BNC connectors (Transmit and Receive)
for a 75-ohm unbalanced interface, or an RJ48C, 8-position, unkeyed modular
connector for a 120-ohm balanced interface. See
the User’s Guide for specifications of the 120-ohm connector and cable.
Cables and Pin Assignments
in
Connecting to a System Terminal
An optional system maintenance terminal may be attached to your Hotwire 7986
Standalone Termination Unit through the modular jack on the rear panel. The
system maintenance terminal allows you to view the status of the unit, and
change configuration options. The terminal must be a VT100-compatible terminal
or a PC running terminal emulation software.
Procedure
To connect your unit to a system terminal:
1. Connect the 9-pin end of the terminal cable into a COM port on your PC.
2. Plug the other end into the modular jack on the rear panel.
3. Set the communication parameters on your PC or terminal to:
— 9600 baud
— 8 bit characters
— no parity
— 1 stop bit
— no flow control
7986-A2-GZ40-00
Press Enter from your terminal or PC to activate the Main Menu for the attached
unit. The system runs diagnostics and status checks. After a few moments, the
Main Menu or Logon screen appears on your terminal.
March 1999
3
Entering Identity Information
After accessing your unit for the first time, use the Change Identity screen to
determine SNMP administrative system information that will be displayed on the
Identity screen of the Status branch. To access the Identity screen, follow this
menu selection sequence:
Main Menu→Control→Change Identity
Network Configuration
The following illustration shows a network application using a 2-port Hotwire 8786
or 8784 M/HDSL Termination Unit for access concentration in a central office
(CO). A frame relay switch and a router are connected, through the termination
unit, to partner units supporting a host or router, and frame relay encapsulated or
unframed data.
Frame
Relay
Switch
Router
7986 (G.703)
CO Site
LTU
CO Site
8786 or 8784
Termination Unit
in 8600 DSLAM
2.048 Mb
over
SDSL
EIA-530A
V.35
7985
Customer
Premises (CP)
G.703
7986
G.703
7986
E1 Host
(Frame Relay
Encapsulated
Data)
Router
(Frame Relay
Encapsulated
Data)
Router
Customer
Premises
NTU
7985
V.35
4
7986 (G.703)
March 1999
7986
G.703
98-16151
7986-A2-GZ40-00
In a DSLAM-to-standalone configuration:
The devices synchronize without altering factory defaults, since the CO unit
defaults to LTU mode, and the CP unit defaults to NTU mode.
In a standalone-to-standalone configuration:
One unit must be changed to run in LTU mode, since standalone units have
a factory default setting of NTU mode.
In both cases the clocking source may have to be altered depending on network
requirements.
Choosing a Configuration Mode
You can make configuration changes either through a VT100-compatible terminal
and the unit’s Configuration menus or by manually changing switches on the
board. The unit comes configured to allow settings to be made through the
Configuration menus.
Configuring the Unit Using the Configuration Menus
Use the Configuration menu to select, display, or change configuration option
settings.
NOTE:
The 7986 Standalone Termination Unit is preconfigured as an NTU. If you
are using this unit as an NTU, the configuration options may not need to be
changed.
The 7986 Standalone Termination Unit has two sets of configuration option
settings:
The Current Configuration (the 7986 Standalone Termination Unit’s active set
of configuration options)
The Default Factory Configuration (a read-only configuration area containing
the factory default configuration options)
To display configuration options, you must first load a configuration into the edit
area. To load a configuration option set into the configuration edit area, follow this
menu selection sequence:
Main Menu→Configuration (Load Configuration From)
Make a selection by placing the cursor at your choice and pressing Enter.
If you select . . .Then . . .
Current
Configuration
Default Factory
Configuration
Configuration
Loader
The selected configuration option set is loaded and the
Configuration Edit/Display menu screen appears.
The selected configuration option set is loaded and the
Configuration Edit/Display menu screen appears.
The Configuration Loader screen is displayed allowing you to
upload or download configurations from a TFTP server.
7986-A2-GZ40-00
March 1999
5
Configuration Edit/Display
The Configuration Edit/Display screen is displayed when the current, customer,
or default configuration is loaded. To access the Configuration Edit/Display
screen, follow this menu selection sequence:
Main Menu→Configuration →Current Configuration
–
or –
Main Menu→Configuration →Default Factory Configuration
main/config/edit Hotwire
CONFIGURATION EDIT/DISPLAY
Network
G.703
System Options
Communication Port
Management and Communication
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menuM
ave
S
Model: 7986
ainMenuExit
Select . . .To Access the . . .To Configure the . . .
NetworkNetwork Interface Options, Table 1DSL network interfaces on
G.703G.703 Interface Options, Table 2G.703 interface.
System Options System Options, Table 3General system options of
the unit.
the unit.
6
Communication
Port
Management
and
Communication
Communication Port Options, Table 4Unit’s COM port options.
Telnet Session Options, Table 5
Communication Protocol Options,
Table 6
General SNMP Management
Management support of the
unit through SNMP and
Telnet.
Determines the error rate at which an excessive error rate (EER) condition is
recognized. The rate is the ratio of the number of CRC errors to the number of bits
received in a certain period.
AutoRate
Possible Settings: Enable, Disable
Default Setting: Disable
Determines whether the unit automatically adjusts to the best line rate for conditions, or
is fixed at the rate in the DSL Line Rate field.
AutoRate is only available when the unit is configured as an LTU.