Paradyne 7984 User Manual

HOTWIRE 7984
M/HDSL STANDALONE
TERMINATION UNIT
WITH DSX-1 INTERFACE
USER’S GUIDE
Document No. 7984-A2-GB20-10
February 1999
Copyright E 1999 Paradyne Corporation. All rights reserved. Printed in U.S.A.
Notice
This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773.
Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. Further, Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes.
Changes and enhancements to the product and to the information herein will be documented and issued as a new release to this manual.
Warranty, Sales, and Service Information
Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty , sales, service, repair , installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:
H Via the Internet: Visit the Paradyne World Wide W eb site at http://www.paradyne.com H Via Telephone: Call our automated call system to receive current information via fax or to speak with a
company representative.
— Within the U.S.A., call 1-800-870-2221 — Outside the U.S.A., call 1-727-530-2340
Trademarks
All products and services mentioned herein are the trademarks, service marks, registered trademarks or registered service marks of their respective owners.
Document Feedback
We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@eng.paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification.
Printed on recycled paper
February 1999
7984-A2-GB20-10
Important Information
!
Important Safety Instructions
1. Read and follow all warning notices and instructions marked on the product or included in the manual.
2. Input power to this product must be provided by one of the following: (1) a UL Listed/CSA Certified power source with a Class 2 or Limited Power Source (LPS) output for use in North America; or (2) a 24 Vdc National Electric Code (NEC) ANSI/NFPA 70/Canadian Electric Code (CEC) Class 2 circuit installed in accordance with articles 1 10-16, 110-17, and 110-18 of the NEC, and articles 2-308, 2-310, 2-312, 2-314, 2-200, and 2-202 of the CEC, or (3) a Safety Extra Low Voltage (SELV) power source with a maximum available output of less than 240 VA, certified for use in the country of installation.
3. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.
4. Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord.
5. Do not attempt to install or service this product yourself, as opening or removing covers may expose you to dangerous high voltage points or other risks. Refer all installation and servicing to qualified service personnel.
6. General purpose cables are provided with this product. Special cables, which may be required by the regulatory inspection authority for the installation site, are the responsibility of the customer.
7. When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary , consult with the appropriate regulatory agencies and inspection authorities to ensure compliance.
8. A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings. If products installed in separate buildings are interconnected, the voltage potential may cause a hazardous condition. Consult a qualified electrical consultant to determine whether or not this phenomenon exists and, if necessary, implement corrective action prior to interconnecting the products.
9. In addition, if the equipment is to be used with telecommunications circuits, take the following precautions:
Never install telephone wiring during a lightning storm.Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the
network interface.
Use caution when installing or modifying telephone lines.Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of
electric shock from lightning.
Do not use the telephone to report a gas leak in the vicinity of the leak.
7984-A2-GB20-10 February 1999
B
Important Information
EMI Warnings
!
WARNING:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation.
!
WARNING:
To Users of Digital Apparatus in Canada: This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment
regulations. Cet appareil numérique de la classe A respecte toutes les exigences du règlement sur le matérial
brouilleur du Canada.
C
February 1999
7984-A2-GB20-10

Contents

About This Guide
H Document Purpose and Intended Audience v. . . . . . . . . . . . . . . . . . . . . . . . .
H Document Summary v. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Product-Related Documents vi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 About the Hotwire 7984 Standalone Termination Unit
H M/HDSL Overview 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Hotwire 7984 Termination Unit Features 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Network Configuration 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Front Panel LED Status Indicators 1-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Rear Panel Interface Connections 1-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H SNMP Management Capabilities 1-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Management Information Base (MIB) Support 1-5. . . . . . . . . . . . . . . . . . .
SNMP Trap Support 1-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Using the Asynchronous Terminal Interface
H User Interface Access 2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Communication Port Settings 2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Initiating an ATI Session 2-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Screen Work Areas 2-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Navigating the Screens 2-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Keyboard Keys 2-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Screen Function Keys 2-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Switching Between Screen Work Areas 2-8. . . . . . . . . . . . . . . . . . . . . . . .
H Ending an ATI Session 2-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7984-A2-GB20-10
February 1999
i
Contents
3 Initial Startup and Configuration
H Overview 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Connecting Power to the Unit 3-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Connecting the Unit to an Optional External DC Power Source 3-2. . . . . . . .
H Connecting to the Network 3-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Connecting to a System Terminal 3-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Entering Identity Information 3-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Choosing a Configuration Mode 3-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Configuring the Unit Using the Configuration Menus 3-6. . . . . . . . . . . . . . . . .
H Configuring the Unit Using the Internal Switches 3-7. . . . . . . . . . . . . . . . . . . .
Switchpack Locations 3-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Switchpack Definitions 3-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Accessing and Displaying Configuration Options 3-10. . . . . . . . . . . . . . . . . . . .
H Configuration Edit/Display 3-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Configuration Loader 3-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Saving Configuration Options 3-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Download Code 3-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 Monitoring the Unit
H What to Monitor 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Viewing System and Test Status 4-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Health and Status 4-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Self-Test Results 4-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Status 4-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Viewing Network Error Statistics 4-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Viewing Network Performance Statistics 4-8. . . . . . . . . . . . . . . . . . . . . . . . . . .
H Viewing DSX-1 Performance Statistics 4-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Viewing 7984 Standalone Termination Unit LEDs 4-12. . . . . . . . . . . . . . . . . . . .
H 7984 Standalone Termination Unit LEDs 4-13. . . . . . . . . . . . . . . . . . . . . . . . . . .
ii
February 1999
7984-A2-GB20-10
5 Testing
H Accessing the Test Menu 5-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Running Network Tests 5-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Line Loopback 5-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Repeater Loopback 5-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTE Loopback 5-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Send Remote Line Loopback 5-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Send and Monitor 511 5-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Device Tests 5-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lamp Test 5-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Ending an Active Test 5-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 Messages and Troubleshooting
H Overview 6-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Configuring SNMP Traps 6-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Device Messages 6-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Troubleshooting 6-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents
7 Security
H Overview 7-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H ATI Access Levels 7-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Creating a Login 7-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Deleting a Login 7-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Controlling SNMP Access 7-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Resetting the Termination Unit’s COM Port or Factory Defaults 7-5. . . . . . . .
8 IP Addressing
H Selecting an IP Addressing Scheme 8-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H IP Addressing Example 8-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Assigning SNMP Community Names and Access Types 7-4. . . . . . . . . .
Limiting SNMP Access through the IP Addresses of the Managers 7-5.
7984-A2-GB20-10
February 1999
iii
Contents
A Configuration Option Tables
H Overview A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Network Interface Options Menu A-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H DSX-1 Interface Options A-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H System Options Menu A-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Communication Port A-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Management and Communication Options Menu A-11. . . . . . . . . . . . . . . . . . . .
Telnet Session Options A-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Communication Protocol Options A-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SNMP Traps Options A-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General SNMP Management Options A-19. . . . . . . . . . . . . . . . . . . . . . . . . .
SNMP NMS Security Options A-21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B Standards Compliance for SNMP Traps
H SNMP Traps B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
warmStart B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
authenticationFailure B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
linkUp and linkDown B-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Enterprise-Specific Traps B-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C Cables and Pin Assignments
H Overview C-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H T1 Network Interface C-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H DSL Network Interface Cable C-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H COM Port Interface Cable C-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Power Input Connector C-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H Optional Power Cable C-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D Technical Specifications
Glossary
Index
iv
February 1999
7984-A2-GB20-10

About This Guide

Document Purpose and Intended Audience
This guide contains information needed to set up, configure, and operate the Hotwire 7984 Multirate High-bit-rate Digital Subscriber Line (M/HDSL) Standalone Termination Unit with DSX-1 interface, and is intended for installers and operators.
Document Summary
Section Description
Chapter 1
Chapter 2
Chapter 3
Chapter 4
Chapter 5
Chapter 6
Chapter 7
Chapter 8
About the 7984 Standalone Termination Unit.
7984 Termination Unit’s features and capabilities.
Using the Asynchronous Terminal Interface.
instructions for accessing the user interface and navigating through the screens.
Initial Startup and Configuration.
setting up the user interface and configuration steps.
Monitoring the Unit.
network statistics to monitor the unit.
Testing.
setup.
Messages and Troubleshooting.
SNMP traps, device messages, and troubleshooting.
Security.
the effective access levels, and controlling SNMP access.
IP Addressing.
regarding IP addresses.
Provides information about available tests and test
Presents procedures for creating a login, setting
Describes the
Provides
Provides procedures for
Describes using the LEDs, status, and
Provides information on
Provides information and examples
7984-A2-GB20-10
February 1999
v
About This Guide
Section Description
Appendix A
Appendix B
Appendix C
Appendix D
Glossary Defines acronyms and terms used in this document. Index Lists key terms, acronyms, concepts, and sections in
Product-Related Documents
Document Number Document Title
8784-A2-GB20
8784-A2-GZ40
Configuration Option Tables.
options, default settings, and possible settings.
Standards Compliance for SNMP Traps.
trap compliance information.
Cables and Pin Assignments.
interface information.
Technical Specifications.
specifications, network and port interfaces, power consumption values, and accessory part numbers.
alphabetical order.
Hotwire 8784 M/HDSL Termination Unit, with DSX-1 Interface, User’s Guide
Hotwire 8784 M/HDSL Termination Unit, with DSX-1 Interface, Installation Instructions
Contains all configuration
Contains SNMP
Contains connector and
Contains physical and regulatory
Contact your sales or service representative to order additional product documentation.
Paradyne documents are also available on the World Wide Web at:
http://www.paradyne.com Select
Service & Support → Technical Manuals
vi
February 1999
7984-A2-GB20-10

About the Hotwire 7984 Standalone Termination Unit

M/HDSL Overview
Hotwiret Multirate High-bit-rate Digital Subscriber Line (M/HDSL) products maximize customer service areas by varying the DSL line rate. This ensures symmetric DSL connectivity over a wide range of telephone line distances and transmission line qualities.
Hotwire products can transport at full (2.048 Mbps) or fractional payload rates over a 4-wire, full-duplex circuit over varying distances based on the conditions of the 4-wire loop. Examples include support for router, multiplexer and PBX connections on 24 gauge (.5 mm) cable up to 21,000 feet (6.4 km).
1
Hotwire M/HDSL is equipped with an automatic configuration capability that reduces the M/HDSL installation process to a simple plug and play mode. Simply connecting the units to the line automatically configures the customer for the maximum data rate supported by the local loop. M/HDSL units can also be configured at fixed line speeds to achieve maximum distances.
Hotwire 7984 Termination Unit Features
The Hotwire 7984 M/HDSL Standalone Termination Unit is an endpoint for the chassis-mounted Hotwire 8784 M/HDSL Termination Unit housed in the Hotwire 8600 or 8800 Digital Subscriber Line Access Multiplexer (DSLAM).
Two Hotwire 7984 M/HDSL Standalone Termination Units can also be configured to operate in a central office LTU to customer premises NTU environment.
The 7984 Standalone Termination Unit offers these standard features:
H Embedded Operations Channel (EOC). Provides remote SNMP Traps,
Telnet session capability over the M/HDSL link, and download capabilities.
H Asynchronous T erminal Interface (ATI). Provides a menu-driven
VT100-compatible terminal interface for configuring and managing the termination unit locally or remotely by Telnet session.
7984-A2-GB20-10
February 1999
1-1
About the Hotwire 7984 Standalone Termination Unit
H Local Management (standalone unit). Provides local management using a:
— Terminal or equivalent through the COM port of the unit — Telnet through the COM port of the unit — NMS connection through the 10BaseT port
H Remote Management (DSLAM card). Provides remote management using:
— VT100 Terminal or PC via the Management Serial port of the DSLAM — Network Management System (NMS) via the COM port or MCC port of
the DSLAM
— Using SNMP or Telnet through the 10BaseT port or the Internal
Management Channel (IMC)
— Telnet over the EOC
H Alarm Indication. Provides front panel status LEDs. H Diagnostic Testing. Provides the capability to diagnose device and network
problems and perform digital loopbacks, pattern tests, and self-test.
H Device and Performance Monitoring. Provides the capability of tracking
and evaluating the unit’s operation, including health and status, and error-rate monitoring.
1-2
February 1999
7984-A2-GB20-10
Network Configuration
Figure 1-1 shows several configurations including a network application using a
2-port Hotwire 8784 M/HDSL Termination Unit in a central office (CO). In this configuration, a frame relay switch and a router are connected, through the termination unit, to partner units supporting a host or router, and frame relay encapsulated or unframed data.
This figure also shows a standalone-to-standalone configuration using either another Hotwire 7984 M/HDSL standalone unit with a DSX-1 interface or a Hotwire 7985 M/HDSL standalone unit with an EIA-530A interface.
About the Hotwire 7984 Standalone Termination Unit
DSX-1
CO Site
Frame
Relay
Switch
Router
DSX-1
CO Site
LTU
7984 7984
DSX-1
CO Site
LTU
DSX-1
DSX-1
8784 T ermination Unit
in 8600 DSLAM
1.544 Mb
Premises (CP)
7984
DSX-1
7984
EIA-530
7985
Customer
T1 Host (Frame Relay Encapsulated
Data)
Router (Frame Relay Encapsulated
Router
CP
NTU
DSX-1
CP
NTU
Data)
7984-A2-GB20-10
7984 7985
DSX-1
EIA-530A
Figure 1-1. Sample M/HDSL Configurations
February 1999
99-16150a-01
1-3
About the Hotwire 7984 Standalone Termination Unit
Front Panel LED Status Indicators
Figure 1-2 shows the front panel of the 7984 Standalone Termination Unit. For more information on front panel LEDs, refer to Chapter 4,
TM
TM
7984 M/HDSL
Figure 1-2. Hotwire 7984 Standalone Termination Unit Front Panel
POWER
ALARM
Monitoring the Unit
TEST
DSL
.
DSX-1
98-16116a
Rear Panel Interface Connections
Figure 1-3 shows the physical interfaces of the 7984 Standalone Termination Unit.
POWER DSLCOM DSX-1
I
O
Figure 1-3. Hotwire 7984 Standalone Termination Unit Rear Panel
98-16117
1-4
February 1999
7984-A2-GB20-10
SNMP Management Capabilities
The termination unit supports SNMP Version 1, and can be managed by any industry-standard SNMP manager and accessed using SNMP by external SNMP managers.
Management Information Base (MIB) Support
For a detailed description of supported MIBs, visit Paradyne’s web site at http://www.paradyne.com. The following MIBs are supported:
H MIB II (RFC 1213 and RFC 1573) – Defines the general objects for use with
a network management protocol in TCP/IP internets and provides general information about the unit. MIB II is backward-compatible with MIB I.
H DS1 MIB (RFC 1406) – Reports the performance status of the DSX-1
interface and supports the features found on the DSX-1 Performance Statistics screen.
H RS-232-Like MIB (RFC 1659) – Defines objects for managing RS-232-type
interfaces (e.g., V.35, RS-422, RS-423, etc.) and supports the synchronous data port on the DSU.
About the Hotwire 7984 Standalone Termination Unit
SNMP Trap Support
H Enterprise MIB – Supports configuration, status, statistics, and tests.
The 7984 Standalone Termination Unit supports traps as defined in RFC 1215. Figure 1-4 illustrates a typical M/HDSL SNMP configuration. Refer to Chapter 8,
IP Addressing
Router
DSX-1
and Appendix B,
DSL
7984
EOC
Standards Compliance for SNMP Traps
Operation, Maintenance and Provisioning Center
Network
AC T5A 250V
RTN48V AAB B
AC
INPUT
48VDC CLASS 2 OR
LIMITED PWR SOURCE
8600
DSLAM
8784
OK
Alrm
TestTXRX
SYSTEM
OK
Alrm
Test1234
SYSTEM
OK
Alrm
Test1234
SYSTEM
DC FUSES T4A, MIN. 48V
5
46
.
3
.
2
.
1
.
STACK
A
B
POSITION
Col1234
DSL PORT
ETHERNET
4
123
DSL PORT
G.703 ALRM
LINK-UP
123
4
DSL PORT
G.703 ALRM
LINK-UP
DC PWR
FAN
ALM
A
B
IN
3
2
MCC 1
OUT SERIAL
Ethernet Interface
8546
RADSL
8715
SDSL
8715
SDSL
Ethernet
LAN
3
2
1
SNMP NMS
.
99-16114a-01
Data
7984-A2-GB20-10
Figure 1-4. HDSL SNMP Configuration
February 1999
1-5
About the Hotwire 7984 Standalone Termination Unit
This page intentionally left blank.
1-6
February 1999
7984-A2-GB20-10

Using the Asynchronous Terminal Interface

User Interface Access
You can communicate with the Hotwire 7984 Standalone Termination Unit with an asynchronous terminal interface (ATI) using one of the following methods:
H Direct connection through the COM port of the standalone unit or through the
serial port of the DSLAM MCC.
H Telnet session through the Embedded Operations Channel (EOC).
2
NOTE:
Only one terminal interface session can be active at a time, and another user’s session cannot be forced to end. To automatically log out a user due to inactivity, enable the Inactivity Timeout option (see Table A-5, Telnet Session
Options, in Appendix A,
Security can limit ATI access several ways. To limit user access or set up login IDs, refer to Chapter 7,
Communication Port Settings
Ensure that the device you connect communicates using these settings:
H Data rate set to 9.6 kbps. H Character length set to 8. H Parity set to None. H Stop Bits set to 1.
Configuration Option Tables
Security
.
).
7984-A2-GB20-10
February 1999
2-1
Using the Asynchronous Terminal Interface
Initiating an ATI Session
The Main Menu screen is displayed on the screen unless a login ID and password is required or the ATI is already in use.
If the ATI is already in use, you will see a connection refused or connection failed message (if you are using a Telnet session), or you will see the IP address of the other user (if you are using the Management Serial port).
If security is enabled on the 7984 Standalone Termination Unit and you used Telnet to access it directly (you did not log in through the MCC), the system prompts you for a login ID and password.
Login Hotwire
LOGIN
Login ID:
Enter Password:
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Ctrl-a to access these functions E
Model: 7984
xit
After you enter a valid login ID and password, the Main Menu appears. If you enter an invalid login ID and password after three attempts, the Telnet session closes or the terminal connection returns to an idle state. Refer to Chapter 7,
Security
.
2-2
February 1999
7984-A2-GB20-10
Using the Asynchronous Terminal Interface
Screen Area
Screen Function Keys Area
main Access Level: Administrator Hotwire
MAIN MENU
Status Test Configuration Control
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Ctrl-a to access these functions E
Model 7984
xit
Entry to all of the termination unit’s tasks begins at the Main Menu screen. The four branches of the Main menu are as follows:
Select . . .
To . . .
Status View system status, diagnostic test results, statistics, LEDs, and device
identity information. Test Select and cancel tests for the termination unit’s interfaces. Configuration Display and edit the configuration options. Control Change the device identity , administer logins, download new firmware, or
initiate a power-up reset of the termination unit.
After selecting an option, what appears on the screens depends on the:
H Current configuration – How your termination unit is currently configured. H Effective security access level – An access level that is typically set by the
system administrator for each interface and each user.
H Data selection criteria – What you entered in previous screens.
7984-A2-GB20-10
February 1999
2-3
Using the Asynchronous Terminal Interface
The following illustration shows the menu paths to the different ATI screens.
Main
System and
Test Status
Network
Error
Statistics
Status Test
Performance
Statistics
Network
Performance
Statistics
Display
LEDs
DSX-1
Statistics
Network
DSX-1 T est
and
Identity
Device
T ests
Network DSX-1
Telnet
Session
Abort T ests
Factory
All
Config
Communication
Protocol Options
Configuration Control
Change
Identity
Configuration
Loader
System
Options
Communication
General SNMP
Management
Download
Code
Administer
Logins
Current Configuration
Port
Download
Edit/Display
Communication
SNMP NMS
Security
Reset
Device
Apply
Management
and
SNMP
Traps
99-16113-01
2-4
February 1999
7984-A2-GB20-10
Screen Work Areas
There are two user work areas:
H Screen area – This is the area above the dotted line that provides the menu
H Screen function key area – This is the area below the dotted line that lists
Menu Path
Using the Asynchronous Terminal Interface
path, menus, and input fields. The menu path appears as the first line on the screen. In this manual, the
menu path is presented as a menu selection sequence with the names of the screens:
Main Menu→Configuration →Load Configuration From→Network Interface Options
function keys specific to the screen, field value choices, and system messages.
Input Fields
Screen
Function
Keys
Field V alue
Choices
main/config/network Hotwire
NETWORK INTERFACE OPTIONS
Margin Threshold: –3db Excessive Error Rate Threshold: 1E–5
Peer IP Address: 111.255.255.000 Clear
Circuit Identifier:
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Ctrl-a to access these functions, ESC for previous menu M S
ave
Select: 1E–4, 1E–5, 1E–6, 1E–7, 1E–8, 1E–9 LOS at Net, Pt
Model: 7984
Clear
ainMenu Exit
n
System
Messages
7984-A2-GB20-10
February 1999
2-5
Using the Asynchronous Terminal Interface
Navigating the Screens
You can navigate the screens by:
H Using keyboard keys H Using screen function keys H Switching between the two screen work areas
Keyboard Keys
Use the following keyboard keys to navigate within the screen.
Press . . .
Ctrl-a Move cursor between the screen area and the screen function
Esc Return to the previous screen. Tab Move cursor to the next field on the screen. Backspace Move cursor to the previous field on the screen. Return (Enter) Accept entry or display valid options on the last row of the screen
Ctrl-k Tab backwards (move cursor one field to the left). Spacebar Select the next valid value for the field. Delete (Del) Delete character that the cursor is on. Up Arrow or Ctrl-u Move cursor up one field within a column on the same screen. Down Arrow or Ctrl-d Move cursor down one field within a column on the same screen. Right Arrow or Ctrl-f Move cursor one character to the right if in edit mode. Left Arrow or Ctrl-b Move cursor one character to the left if in edit mode. Ctrl-l Redraw the screen display , clearing information typed in but not
To . . .
keys area below the dotted line at the bottom of the screen.
when pressed before entering data or after entering invalid data.
yet entered.
2-6
" Pr ocedure
To make a menu or field selection:
1. Press the Tab key or the right arrow key to position the cursor on a menu or
field selection. Each selection is highlighted as you press the key to move the cursor from position to position.
2. Press Enter.
The selected menu or screen appears.
3. Continue Steps 1 and 2 until you reach the screen you want.
February 1999
7984-A2-GB20-10
Screen Function Keys
Using the Asynchronous Terminal Interface
The current setting or value appears to the right of the field name. You can enter information into a selected field by:
H Typing in the first letter(s) of a field value or command. H Switching from the screen area to the screen function area below the dotted
line and selecting or entering the designated screen function key.
If a field is blank and the Field Values screen area displays valid selections, press the spacebar and the first valid value for the field will appear. Continue pressing the spacebar to scroll through other valid values.
All screen function keys located below the dotted line operate the same way (upper- or lowercase) throughout the screens.
For the screen function . . .
Select . . . And press Enter to . . .
ClrFar F or f Clear far-end network statistics and refresh the screen. ClrNear N or n Clear near-end network statistics and refresh the screen. ClrStats S or s Clear DSX-1 statistics and refresh the screen. Delete L or l Delete data. Exit E or e Terminate the async terminal session. MainMenu M or m Return to the Main Menu screen. New N or n Enter new data. PgDn D or d Display the next page, or group of entries. PgUp U or u Display the previous page, or group of entries. ResetMon R or r Reset an active Monitor 511 test counter to zero. Save S or s Save information.
7984-A2-GB20-10
February 1999
2-7
Using the Asynchronous Terminal Interface
Switching Between Screen Work Areas
Select Ctrl-a to switch between the two screen work areas to perform all screen functions.
" Procedure
To access the screen function area below the dotted line:
1. Press Ctrl-a to switch from the screen area to the screen function key area
below the dotted line.
2. Select either the function’s designated (underlined) character or press the
Tab key until you reach the desired function key.
Example:
To save the current screen, type s or S (Save).
3. Press Enter.
4. To return to the screen area above the dotted line, press Ctrl-a again.
main/config/network Hotwire
NETWORK INTERFACE OPTIONS
Margin Threshold: –3db Excessive Error Rate Threshold: 1E–5
Peer IP Address: 111.255.255.000 Clear
Circuit Identifier:
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Ctrl-a to access these functions, ESC for previous menu M S
ave
Model: 7984
Clear
ainMenu Exit
2-8
February 1999
7984-A2-GB20-10
Ending an ATI Session
Use the Exit function key from any screen to terminate the session.
" Procedure
To end a session with the asynchronous terminal interface:
1. Press Ctrl-a to go to the screen function key area below the dotted line.
2. Save changes if required. A confirmation message appears if you have made
but not saved changes to your configuration.
Using the Asynchronous Terminal Interface
3. Tab to E
xit (or type e or E) and press Enter.
7984-A2-GB20-10
February 1999
2-9
Using the Asynchronous Terminal Interface
This page intentionally left blank.
2-10
February 1999
7984-A2-GB20-10

Initial Startup and Configuration

Overview
This chapter provides instructions on how to access and configure your unit for the first time. This chapter includes procedures for:
H Connecting power to the unit. H Connecting the unit to the network. H Connecting a system terminal.
3
H Providing initial unit identity information or changing existing identity
information.
H Configuring your unit using internal switchpacks or using the Configuration
Edit menus.
H Choosing the current or factory default configuration options or downloading
configuration options from a TFTP server.
H Modifying current configuration options using the Configuration Edit/Display
menu.
H Saving your changes. H Downloading unit firmware from a TFTP server.
7984-A2-GB20-10
February 1999
3-1
Initial Startup and Configuration
Connecting Power to the Unit
If your package includes a power pack:
Plug the power pack into an ac outlet having a nominal voltage rating between 100–240 Vac. Connect the output cable of the power pack to the connector marked POWER on the rear panel.
If your package includes a direct-connection +24 Vdc power cable:
unit to an external +24 Vdc power source as described in
an Optional External +24 Vdc Power Source
If you will use a –48 Vdc power supply:
.
Connect the unit to an external –48 Vdc power source as described in the documentation shipped with the power supply and power cable.
Connecting the Unit to an Optional External +24 Vdc Power Source
Using the dc power cable, the Hotwire 7984 Standalone Termination Unit is capable of operating on a +24 Vdc power supply.
" Procedure
To use the dc power cable:
1. Connect the green wire to a suitable ground.
2. Connect the orange wire to the +24 Vdc source.
3. Connect the white wire to the return.
4. Cut the black, red, and blue wires off at the outer insulation.
5. Plug the power connector into the 7984 Standalone Termination Unit.
Connect the
Connecting the Unit to
3-2
1 2 3 4 5 6
Black
Red
Green
White
Orange
Blue
+24 Vdc Power Supply Pinouts
February 1999
X X
Ground RTN
+24 Vdc X
99-14158-02
7984-A2-GB20-10
Connecting to the Network
" Procedure
To connect your unit to the network:
1. Connect one end of the network cable into the rear panel DSL jack.
2. Connect the other end to your DSL network interface.
NOTE:
Do
not
use a flat VF network cable as this may severely degrade the performance of the termination unit. Use only Cat 5 twisted-pair network cable.
Connecting to a System Terminal
An optional system maintenance terminal may be attached to your Hotwire 7984 Standalone Termination Unit through the modular jack on the rear panel. The system maintenance terminal allows you to view the status of the unit, and change configuration options. The terminal must be a VT100-compatible terminal or a PC running terminal emulation software.
Initial Startup and Configuration
" Procedure
To connect your unit to a system terminal:
1. Connect the 9-pin end of the terminal cable into a COM port on your PC.
2. Plug the other end into the modular jack on the rear panel. — If your PC requires a 25-pin connector to the COM port, see Appendix C,
Cables and Pin Assignments
3. Set the communication parameters on your PC or terminal to: — 9600 baud — 8 bit characters — no parity — 1 stop bit — no flow control
, for the correct cable pinouts.
7984-A2-GB20-10
February 1999
3-3
Initial Startup and Configuration
Entering Identity Information
After accessing your unit for the first time, use the Change Identity screen to determine SNMP administrative system information that will be displayed on the Identity screen of the Status branch. To access the Identity screen, follow this menu selection sequence:
Main Menu→Control→Change Identity
main/control/change_identity Hotwire
IDENTITY
System Name: lllQJ98-001 System Location: Bldg. A412, 2nd Floor, Left cabinet System Contact: C. Parker 800-727-2396 pager 888-555-1212 Clear
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Ctrl-a to access these functions, ESC for previous menu M S
ave
Model: 7984
Clear Clear
ainMenu Exit
The three System entry fields are alphanumeric and provide 128 characters for each field. The System entries appear on the Identity display as shown above. The SNMP System entry fields are:
H System Name: The general SNMP system name. H System Location: The physical location of the SNMP-managed device. H System Contact: Identification information, such as contact name, phone
number, or mailing address.
3-4
Valid entry values are any printable ASCII character. ASCII printable characters include:
H Numeric 0–9 H Upper- or lowercase A–Z H Space H All ASCII symbols except the caret (^)
Select Clear to reset a field to a null value.
February 1999
7984-A2-GB20-10
Loading...
+ 92 hidden pages