Overview
The SR150 is a weatherproof, stand-alone, fully supervised outdoor wireless siren with built-in strobe light and wireless transceiver. The SR150 uses 2-way wireless communication, which provides continuous supervision between the panel and siren with fast response to alarm signals within four seconds.
With its tough weatherproof construction, the SR150 operates reliably from -30ºC to 50ºC (-22ºF to 122ºF) when using alkaline batteries or power supply.
With normal use, the SR150 will function up to 3 years without the need to replace the batteries (battery life can be extended by using an optional AC or DC power supply). This guide describes how to install and configure the SR150 wireless siren.
Included Items
1 strobe lens (available in red, blue, amber, or clear)
•3 D type alkaline batteries
Required/Optional Items
•Mounting hardware
8-16VAC, or 9-20VDC external power supply (optional)
Compatibility
EVOHD v.1.20 or higher
EVO192 v3.20 or higher
MG/SP series v4.0 (except SP4000)
MG6250 v3.0 or higher
RTX3 v1.5 or higher/ v5.30 for EVO panels
K32LCD v1.3 or higher
BabyWare v2.8 or higher/ v2.30 for EVO panels
Features
Internal protective plastic cover
•Built-in transceiver
100dB wireless siren
•Integrated strobe light
Weather-resistant design using a PC/ABS enclosure with UV protection
Fast alarm response time (4 seconds)
2.5 hour alarm display (strobe flashes every 4 seconds after bell
Siren presence supervised by control panel
Dual tamper protection for cover removal and removal from wall
Assign up to 4 sirens per control panel
Firmware upgrade via 307USB
•Siren test mode
SR150-EI14 05/2015 SR150 V2.30 PARADOX.COM
cut-off )
Figure 1: SR150 Overview
Number Overview Description
1
100dB siren
2
Battery pack (3 “D” size alkaline batteries) with gold plated battery connections or optional 3.6VDC
3
Power supply input (8-16Vac / 9-20VDC)
4
In-field firmware upgrade connector
5
Dual-action tamper switch (detects when cover is removed and when unit is removed from wall)
6
Internal protective plastic cover
7
Test switch
8
LED status indicators and signal strength (See LED Feedback below for details)
9
Antenna (can be extended using an RG6 or RG59 coaxial cable with standard male F connectors. Attach the antenna using a female/female F adaptor)
10
Strobe lights
LED Feedback
Figure 2: LED Status Indicators
The following table describes LED Status Indicators.
LED
Indicator
TX Sending data
RX Receiving data
PSSI Signal strength siren receives from control panel
Flash 4x - strong signal Flash 3x - good signal Flash 2x - weak signal Flash 1x - very weak signal (relocate) No flash - no signal
Status Flash once/sec. - processor is on
Flash once/4 sec. - power save mode
Description/Status
Programming
Upgrading Firmware
Program the SR130 either though a supported keypad or through BabyWare software (BabyWare).
Programming with Keypads
Featu re Program
MG6250 MG/SP EVO192/HD
Sections correspond to sirens 1 - 8
Learn Siren
Sections correspond to sirens 1- 4. EXAMPLE: [0802]: Learn Siren 2 for MG6250
[0801] - [0804] [683] - [686] [2851] - [2858]
Press and hold the Reset/Training switch for 3 seconds after entering the section to learn the siren. WAR NIN G: When pressing the Reset/Training switch, the SR130 squawks and the strobe light flashes five times to confirm siren registration to the panel
Assign Partition to
- - [2861] - [2868]
Siren
Display Signal
[0801] - [0804] [687] - [690] [2871] - [2878]
Strength
Press and hold the Reset/Training switch for 3 seconds after entering the section to display the siren signal strength that the panel receives. Requires keypad K32LCD V1.3 or higher
Label Siren
Te mp o ra r y
[0811] - [0814] [691] - [694] -
Labels identify sirens when reporting events (for MG/ SP only: via e-mail through the IP100/ IP150. For MG6250 through SMS personal reporting) and for troubleshooting purposes. Maximum 16 characters
[0800] [695] [2870]
Tamper Switch Deactivation for Maintenance
Press [ENTER] after entering the section to deactivate tamper alarm until the cover is reinstalled or after 30 minutes
Panel Supervision of
[0820]
[587]
-
Siren
: Enabled (default)
ON
OFF: Disabled
The control panel supervises the presence of the SR150. If lost, the control panel follows global supervision options set in the control panel
Programming with BabyWare
1. Open BabyWare > Connect your Account.
2. In the Main window: Select the Add Item button > Wireless Sirens.
3. Fill-in the SR150 label, location and serial number.
4. Select Save.
Upgrade SR150 firmware through the Paradox In-Field software (V3.0 or higher) using the 307USB Direct Connect Interface. The SR130 requires the batteries installed in order to upgrade the firmware.
Note: Ensure that the SR150 is awake before upgrading the firmware.
To wake up the siren: press the Test button (see connector #7 in
Figure 1). The siren provides a 60 second delay in order to begin
the update.
1. Remove the front cover.
2. Connect the 307USB to the In-Field connector (see connector #4 in
Figure 1).
3. Upgrade according to the firmware upgrade instructions: Go to www.paradox.com >Software > In-Field Firmware Upgrade Instructions.
Tamper Supervision
If a tamper is detected, the SR150 will sound an alarm and the strobe light will flash for 4 minutes. The control panel will follow the global supervision options set in the panel.
Specifications
Specification Description
Power 4.5Vdc (3 “D” size alkaline batteries)
Optional: 8-16Vac / 9-20Vdc external power
Battery life Up to 3 years based on normal use (e.g. 2 alarms
per year with strobe for 2.5 hours and 8 squawks per day at an average of 25 power source will extend battery life
Consumption Sleep: 22uA, Standby: 130uA, Alarm: 550mA
RF frequency 433MHz or 868MHz
Siren 100dB (1 meter)
Dimensions 24cm X 6.cm X 18cm (9.5in X 2.3in X 7in)
Operating Tem p er at ur e
RF range 70m (229ft)
Battery only: -30ºC to 50ºC (-22ºF to 122ºF)
ºC (77ºF). Using optional
Certifications
CE EN 50131-4 Grade 2 EN 50130-5 Class IV
Warranty
For complete warranty information on this product, please refer to the Limited Warranty Statement found on the Statement. Your use of the Paradox product signifies your acceptance of all warranty terms and conditions. Please ensure that your use of the Paradox product is in compliance with local, national, and international laws.
© 2015 Paradox Security Systems (Bahamas) Ltd. All rights reserved. Specifications may change without prior notice. US, Canadian and international patents may apply. BabyWare and Paradox are a trademarks or registered trademarks of Paradox Security Systems (Bahamas) Ltd. or its affiliates in Canada, the United States and/or other countries.
SR150-EI14 05/2015 SR150 V2.30 PARADOX.COM