RX1: Wireless Receiver
V1.0
Specifications
Location
The location of the RX1 affects its performance. In order to ensure the best
possible signal reception, the following list of location criteria should be
respected:
• Select an installation site that is free of obstacles that reflect and absorb radio
frequency (RF) signals, as well as interference that may distort signals. A void
installation near or in the path of strong RF fields (e.g., neon lights,
computers), on or near metal objects, circuit breaker boxes, air conditioners,
or heating ducts since they may cause interference and reduce the module’s
sensitivity.
• Select a site that is not susceptible to drastic temperature changes.
• Mount the RX1 as high as possible.
• Avoid mounting the RX1 in the basement as the range of the module is
reduced when mounted below ground level. If it is absolutely necessary to
mount the module in the basement, mount the module as high and as close
to the underside of the first floor as possible.
• Mount the RX1 on a wall allowing at least 5cm (2in) around the module to
permit adequate ventilation and heat dissipation.
Installation
NOTE: Only one RX1 module can be
connected to an E55 or SP Series panel
(V5.0 and higher).
1. Control panel bus connection.
2. If the current draw exceeds 150mA on
PGM1 or PGM2, use a relay. Connect the
RX1’s RED connector to the relay’s “R”
connector, and the PGM connector (PGM 1
or PGM2) to the relay’s BLK connector.
NOTE: Record the serial number of all
wireless modules to be used with the RX1.
LED Feedback
Power input voltage: 12Vdc
Frequency: 433MHz or 868MHz
Sensitivity: -110dBm (433MHz) or -106dBm (868MHz)
Current consumption: 25mA
Dimensions (no antenna): 5.1cm x 8.3cm x 2cm (2in x 3.25in x 0.78in)
Operating temperature: 0ºC to 50ºC (32ºF to 122ºF)
PGM outputs: PGM1 and PGM2 - via PGM 13 and 14 of panel
Compatibility: • E55 / Spectra SP control panels V5.0 and higher
• REM1 / RAC1 remote controls
• DCT10 / DCTXP2 / DCT2 door contacts (SP only)
• PMD1P / PMD75 / PMD85 motion detectors (SP only)
• SD738 smoke detector (SP only)
Antenna: Monopole antenna; Error correction algorithm
Description
The RX1 Wireless Receiver
adds wireless receiving
capability to the E55 and SP
Series panels (V5.0 and
higher). Adding the RX1 to
an installation allows for the
use of REM1 remotes as well
as wireless one-way zone
transmitters (SP Series only)
with the system.
Features
• Up to 32 remote controls
• Up to 32 wireless zones (SP only)
• 2 on-board programmable PGMs
• 4-wire bus connection
• Feedback LEDs (Bus / RX)
• In-field firmware upgradable
• Compact design
• RF jamming supervision
• Low battery, tamper and check-in
supervision
• Transmitter signal strength display
1
2
3
4
7
5
Overview
1. Mounting holes
2. RF RX LED
3. Bus Communication LED
4. Serial connection
5. Bus connection
6. Antenna
7. PGM connection
6
1
*Possible causes: GRN/YEL short, GRN/YEL reverse, communication failure, too many modules, bus power too low
Legend
G = Green
= Off
= On
= Flashing
LED State Condition
Receiving RF signal
RF jamming
Communicating on bus
No power / bus trouble*
Firmware Upgrade
The RX1 firmware can be upgraded using a serial connection. Upgrading the
firmware requires the following tools which are available at paradox.com >
Software > In-Field:
• In-Field Firmware Upgrade software
• Firmware upgrade instructions
Programming
When installing for use with SP Series and E55 systems (V5.0 and higher), the
following programming sections apply (bold = default):
Onboard PGMs
The RX1 includes two on-board PGMs which appear as PGMs 13 and 14 in the
SP Series / E55 panel (V5.0 and higher). Refer to the panel’s Programming
Guide for instructions on PGM programming.
Section Description
[061] - [092 ] Wireless serial numbers
[101] - [132] Wireless transmitter signal strength
[610] - [642] Remote control button assignment
[651] - [682] Remote control user assignment
[705] Supervision Options
[6] [7]
RF Zone
Supervision Options
Keypad / Bus Module
Supervision Options
Off Off Disabled Disabled
Off On Trouble only Trouble only
On Off
Disarmed: trouble only
Armed: follow zone’s alarm type
Trouble only
On On
Disarmed: audible alarm
Armed: follow zone’s alarm type
Audible alarm
[706] General Zone Options
Option OFF ON
[1] Check-in supervision time N 24 hours N 80 minutes
Warranty
For complete warranty information, please visit www.paradox.com/terms. Your use of the Paradox
product signifies your acceptance of all warranty terms and conditions. Esprit E55 and Spectra SP
are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in
Canada, the United States and/or other countries. For the latest product approvals, such as UL and
CE, please visit www.paradox.com. © 2009 Paradox Security Systems Ltd. All rights reserved.
Specifications may change without prior notice.
Patents
One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319,
5920259, 5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and other pending
patents may apply. Canadian and international patents may also apply.
RX1-EI00 09/2009 Printed in Canada
PARADOX.COM