Paradox DGP-641 User Quick Reference Manual

The LCD screen will guide you through the operations
Use arrow buttons to scroll menu or choices
ON = AC power OFF = Power failure
Green:
Red:
ON = Area(s) armed OFF = Area(s) disarmed FLASH = Alarm
User’s Quick Reference Guide
“AC” LIGHT
“STATUS” LIGHT
STEP 1: Enter [ACCESS CODE] STEP 2: Press STEP 3: Press STEP 4: Enter the 2-digit User
Number or scroll list, and press
STEP 5: Enter new User Code
STEP 6: Program User Options from
Table 1 then press
STEP 7: Program Area Assignment
from Table 2 then press
In Steps 6 and 7:
When the number appears in the brackets, the number is ON and the feature or area is accessible.
Table 1: User Options
[1] ON [2] OFF : Master
Modifies User Codes only
[1] ON [2] ON: Full Master
Modifies User Codes, User Options, and Area Assignment
[3] ON: Duress
Code used to send silent alarm when forced to arm/disarm system
[4] ON: Bypass
Can use Bypass Programming
[5] ON: Arm only
Cannot disarm
[6] ON: Stay & Instant Arm
Can Stay or Instant Arm
[7] ON: Force Arm
Can Force Arm
[8] ON: Keypad obeys code
Keypad allows access to area(s) assigned to code
[8] OFF : Code obeys keypad
Code only allowed access to Keypad’s assigned area(s)
Table 2: Area Assignment
[1] ON: Access to Area 1 [2] ON: Access to Area 2 [3] ON: Access to Area 3 [4] ON: Access to Area 4 All OFF: Code controls PGM only
ACCESS CODES
To Stay Arm *
(Arms Area’s perimeter)
One-touch Button, [if enabled:
To Force Arm*
(Arms Area without waiting for all zones to close)
One-touch Button, [if enabled:
To Regular Arm*
(Arms entire Area)
One-touch Button, [if enabled:
To Instant Arm *
(Stay Arms Area, but if any zones are breached, it will instantly cause an alarm)
One-touch Button, [if enabled:
To Disarm(when entering) Enter [ACCESS CODE]
To Disarm (from within perimeter) Enter [ACCESS CODE] and press *
To arm
when leaving:
To arm
when staying:
Enter [ACCESS CODE] then press:
ARMING AND DISARMING
*Then choose an area to arm or disarm if necessary
DGP-641
PRINTED IN CANADA 10/99 K641EQ-01
Security Company: ( )
Enter the zone number or scroll the list and press when the desired zone appears on the screen.
OR
Your installer can program the system to have up to four separate areas.
To view or choose area,press & hold: Area 1: Area 2:
Area 3: Area 4:
Made a mistake?
Press To erase entry or revert to last step
Normal Mode
Shows the time, date, and scrolling messages.
Confidential Mode
Shows “Confidential”, date & time only. Press button or enter code to return to Normal Mode.
To view the alarms that occurred last armed period.
Press
ALARM MEMORY DISPLAY
Press and hold a button without entering your Access Code.
Available for the arming features, disarming, Bypass Programming, Event Record display, and the keypad settings. Each One-touch Button must be enabled by the installer.
ONE-TOUCH BUTTONS
All zones that were breached during the last armed period will scroll on the screen.
1)
2) Press
Bypassed zones remain unarmed when the area is armed.
One-touch Button, [if enabled:
Press
Press for Bypass Recall
then choose one:
3)
2)
BYPASS PROGRAMMING
Press
1) Enter [ACCESS CODE]
Keypad beeps when the zone opens.
to select the zones:
Press
Press
Press
to program time period:
A) Enter the time you want to
enable all the Chimed zones. (HH:MM)
B) Enter the time you want to
disable all the Chimed zones. (HH:MM)
2)
CHIME PROGRAMMING
1) Enter [ACCESS CODE]
To re-bypass the zones bypassed during last armed period.
In Step 2 of Bypass or Chime Programming, re-enter the zone number to disable the feature.
Enter the zone number or scroll the list and press when the desired zone appears on the screen.
OR
then choose one:
3)
Press
PARTITIONED SYSTEM
EVENT RECORD DISPLAY
The Event Record Display will keep in memory the user-initiated actions, the alarms, and the troubles that have occurred in your system. You can only view the events that occurred in the areas assigned to your Access Code.
One-touch Button, [if enabled:
1) Enter your [ACCESS CODE]
2) Press
3) To view events press:
4) Use
5) Press
for all areas OR Choose specific area by pressing its corresponding button.
to view subsequent events
to exit
KEYPAD SETTINGS
You can modify the keypad’s settings to suit your needs.
1) Press and hold
2) Choose one. Press:
3) Press
4) Press
5) Press
Scroll Speed: time between messages (10 is slowest)
Backlight: keypad’s light (7 is brightest)
Contrast: character intensity (4 is strongest)
or to modify
to save
to exit
for next setting or
to exit
Loading...