![](/html/54/5404/5404362d1f3a26a3ea3ef0d4a2e931163ae487541d91c323eb295faa7d24b38c/bg1.png)
20-Zone, and 48-Zone LED Keypads V1.3
(DGP-620/648)
Programming Guide
Bold = Default Setting
SECTION [003]: General Options
Option OFF ON
[1] Muting l Disabled l
[2] Exit Delay Beep l Disabled l
[3] Not used l N/A l N/A
[4] Chime on Zone Closure l Disabled l
[5] Not used l N/A l N/A
[6] Not used l N/A l N/A
[7] Not used l N/A l N/A
[8] Not used l N/A l N/A
Enabled
Enabled
Enabled
MODULE PROGRAMMING MODE
The keypad, like all other modules in the Digiplex system, is
programmed through the control panel. To enter the Module
Programming Mode:
Step 1: Press and hold the [0] key.
Step 2: Enter the [INSTALLER CODE] (by default 000000).
Step 3: Enter section [953].
Step 4: Enter the keypad’s 8-digit [SERIAL NUMBER].
Step 5: Enter the 3-digit [SECTION] to program.
Step 6: Enter the required [DATA].
PROGRAMMING GUIDE
Serial Number: ___/___/___/___/___/___/___/___
Location:______________________________________________
Bold = Default Settings
SECTION [001]: Partitioning
Option OFF ON
[1] Partition 1 l Disabled l
[2] Partition 2 l Disabled l
[3] Partition 3 l Disabled l
[4] Partition 4 l Disabled l
[5] Not used l N/A l N/A
[6] Not used l N/A l N/A
[7] Not used l N/A l N/A
[8] Not used l N/A l N/A
Enabled
Enabled
Enabled
Enabled
SECTION [004]: Beep on Trouble
Option OFF ON
[1] System & Clock Loss l Disabled l
[2] Communicator l Disabled l
[3] Modules & Bus l Disabled l
[4] All Zones Troubles l Disabled l
[5] Not used l N/A l N/A
[6] Not used l N/A l N/A
[7] Not used l N/A l N/A
[8] Not used l N/A l N/A
SECTION [005]: General Options
Option OFF ON
[1] PGM State l Normal
Open
[2] PGM Timed Mode l Disabled l
[3] PGM Base Time l 1 Second l
[4] PGM Override l Disabled l
[5] Keypad Tamper l Disabled l
[6] Not used l N/A l N/A
[7] Not used l N/A l N/A
[8] Not used l N/A l N/A
Section:
[006] ___/___/___
PGM Timer 000 to 255 (refer to the Digiplex LED Keypad Installer
Manual).
l
Enabled
Enabled
Enabled
Enabled
Normally
Closed
Enabled
1 Minute
Enabled
Enabled
SECTION [002]: General Options
Option OFF ON
[1] Not used l N/A l N/A
[2] Not used l N/A l N/A
[3] Not used l N/A l N/A
[4] Confidential Mode l Disabled l
[5] To Normal Mode
(if [4] is enabled)
[6] Not used l N/A l N/A
[7] Not used l N/A l N/A
[8] Not used l N/A l N/A
l Enter
Code
Enabled
l Press
Button
[007] ___/___ ( 1 2 3 4 5 6 7 8 )
PGM Activation Event
For the PGM Table refer to the Digiplex Programming Guide.
[008] ___/___ ( 1 2 3 4 5 6 7 8 )
PGM Deactivation Event
For the PGM Table refer to the Digiplex Programming Guide.
[009] Zone Display (DGP-620 only)
20 - Zone Keypad: l [0] = 1 to 20 l [1] = 21 to 40
![](/html/54/5404/5404362d1f3a26a3ea3ef0d4a2e931163ae487541d91c323eb295faa7d24b38c/bg2.png)
Figure 1 - Connecting Keypads & Keypad Zones
Figure 2 - Basic Keypad Overview