Panasonic XE9SKUA User Manual

2018 Full Line Catalog
Air Conditioning and Heat Pump Products
NEW PRODUCT LINE UP
April 2018
Panasonic has produced over 100 million
Global Brand
Our global brand serves over 100 counties in all climate zones around the world.
Europe
31
countries
CIS
countries
10
MiddleEast
countries
10
NorthAsia
countries
3
Asia
15
countries
NorthAmerica
countries
Africa
7
countries
Oceania
countries
3
Our air conditioner designs consider local climate characteristics and are used in a wide range of extreme hot to extreme cold regions and countries.
LatinAmerica
20
countries
In extreme cold climate and heavy snow fall conditions it is necessary to protect the outdoor unit from freezing. Panasonic has developed special knowledge and technology for cold climate regions including Siberia and North America.
Panasonic can be characterized as a global pioneer in extreme cold climate heat pump design and installations.
1
INDEX
* As of the end of 2014 (According to our research)
Our Evolution
Forever and ever.
1958
A window-type.
1965
Launched indoor and outdoor separate-type.
1969
Launched wall mounted indoor unit with outdoor unit separated.
P.1 - About Panasonic
P.3 - Tecnology
P.5 - Quality and Reliability
P.7 - Superb Comfort
P.9 - Advanced Inverter & ECONAVI Technology
P.11 - Air Conditioner and Heat Pump Line-Up
P.13 - Model Feature Chart
P.14 - Features
P.15 - Premium Series Wall-Mount Heat Pump
P.17 - Deluxe Series Wall-Mount Heat Pump
P.18 - Pro Series Wall-Mount Heat Pump
P.19 - Wall-Mounted Heat Pumps
P.20 - Wall-Mount Air Conditioners
P.21 - Ceiling Suspended Heat Pumps
P.23 - 4-Way Cassette Heat Pumps
1972
Launched heat & cool air conditioner.
Launched Heat Pump mini split making heating & cooling possible year-round.
1981
Launched low ambient heat pump units that provide heat in extreme cold climates.
1983
Launched inverter air conditioner.
2008
First model equipped human sensor launched.
2010
First model equipped ECONAVI launched.
2014
XE series –15˚F heat operation
P.25 - Slim Duct Heat Pumps
P.26 - Concealed Duct-Medium Static Heat Pumps
P.27 - Multi-Zone Systems / Outdoor Units
P.29 - Multi-Zone Systems / Indoor Units
P.31 - Multi-Zone Systems / 2 Zone / 2-3 Zone
P.33 - Multi-Zone Systems / 2-4 Zone / 2-5 Zone
P.35 - Multi-System Capacity and Combinations
P.37 - Residential Controllers (RAC)
P.38 - Residential / Light Commercial Controllers (PAC)
P.39 - Wireless Home
P.40 - Wireless Home App
P.41 - Wireless Home - BACnet Integration
P.43 - Controllers, Communication and Integration
P.44 - Accessories / Line Set
P.45 - Pipe Lengths, Fittings, Elevations and Refrigerant
P.46 - Operation Range / Multi-Zone Wiring
P.47 - Multi-Split Tube Adaptors
P.48 - Model Identification
2
Rugged design that continues to operate high
performance even in
cold climate of -15°F.
2
PRECISE
Precise design
3
5
6
1
High-Efficiency Compressor
High-performance compressor with wide power output range operates accurately with less than 1 ampere for precise operation.
1
Low Vibration
Anti-vibration rubber mounts on the compressor legs absorb impact and improves durability.
Components arranged in an orderly manner are
The compressor, which is the heart of the air conditioner, is wrapped in insulation to provide
3
2
Inverter Technology
Advanced drive technology adjusts precise compressor motor rotation. During the start-up phase, the compressor quickly provides powerful, high-speed rotation; during the run phase the compressor smoothly shifts to a low speed rotation for energy savings.
performance even in
4
TOUGHNESS
Rugged body
3
High-Efficiency Blades
Frost on heat exchanger is frequent in cold climates. The three blade, high static pressure design moves air quietly and evenly even under harsh conditions
4
Blue Fin Condenser
This special coating prevents rust from salt air and moisture from rain and melting snow and assures longer life of the heat exchanger.
3 layer structure 3 times longer lasting
Note: According to Panasonic test results.
Water Air Salt Content
Corrosion-Resistant Layer
Base Material
Corrosion-Resistant Layer
5
Base Pan Heater / Multiple Drain Ports
A heating element placed around the base pan prevents freezing condensate inside the outdoor unit. Multiple drain holes assist prompt drainage.
Quiet
Smooth rotation and low vibration ensure quiet operation and durability.
Silicone Coating
The brains of the air conditioner, printed circuit board is coated with silicon to prevent malfunction from insulation deterioration.
6
Powder Coated Finish
for guardrails, automobile parts provide corrosion resistance and durability.
4
Reliability and exceptional quality with over 200 quality assurance tests.
A rugged design ensures that the air conditioners will continue to keep the room comfortable, and provide
Durability
reliable operation for many years. Panasonic believes this is the true value of an air conditioner and the reason we subject them to a wide range of stringent durability tests.
Shock Resistance
Panasonic conduct tests under conditions that are much more severe than actual operating conditions.
The outdoor unit is provided with IPX4 waterproof compliance. Also, an operating durability test has been conducted at a temperature up to 130 °F down to -13°F in test chamber.
Even with the large impacts during transportation, the product packaging has been strengthened to prevent it from being damaged.
5
We place a weight on top of the test package and leave it in a room at high-temperature and humidity. After this warehouse simulation test, the product is checked for proper operation.
Comfort
Quality
An actual air conditioner is operated in a test room that simulates a standard living room. The test makes it possible to conrm optimum performance level under ever-changing conditions.
A variety of tests are conducted to judge the visibility of the button colors, operating ease. The remote control is also subjected to a 1.5-meter dropping test from various angles.
Panasonic air conditioners comply with all necessar y leading industrial standards and regulations required for the market in each country.
Panasonic "eco ideas" factories reduce CO emissions and conduct regional-based environmental communication activities to contribute to both the global environment and the local communities.
2
6
With Panasonic, heating and cooling are all-
Winter Summer
Panasonic inverter technology continually adjusts its compressor rotation speed to provide maximum performance
Superb comfort
at all times. This precise operation enables quick cooling or heating while reducing power consumption compared to conventional non-inverter units.
Precise Control
Reduces Electricity Consumption
Panasonic inverter air conditioners/heat pumps are designed to give you exceptional energy savings while ensuring you stay comfortable at all times.
7
Constant Comfort
Precise temperature control with a wide power output range enables an Inverter air
room occupancy levels, providing constant comfort.
in-one providing year-round comfort.
The air conditioning heat pump consists of a single or multiple indoor units and a single outdoor condenser unit. The indoor and outdoor units are connected by refrigerant pipes that cycle refrigerant gas between the indoor and outdoor units. The direction of
All seasons
Year-round use
indoor unit indoor unit
the gas can be switched which changes operation between heating and cooling. This switching change is done with a simple button push on the remote controller and heating and cooling comfort is provided year-round.
outdoor unit outdoor unit
At heating operation At cooling operation
temperature refrigerant. Cool air is drawn into the indoor unit and Warm air is released into the room. The refrigerant cycle continually repeats.
Simply said, heat is transferred from outdoors to indoors using a compressor and high pressure, high
high temperature refrigerant in a reverse cycle from heating. Warm moist air is drawn into the indoor unit and Cool dry air is released into the room. The refrigerant cycle continually repeats.
Simply said, heat is transferred from indoors to outdoors using a compressor and high pressure,
Quick Cooling and Heating
Panasonic Inverter air conditioner/heat pump can operate with higher cooling/heating power during the start-up period to cool/heat the room faster than non-inverter models.
Whisper Quiet Operation
The indoor operating noise has been reduced by 5dB as the Inverter constantly varies its output power to enable more precise temperature control.
8
Advanced Inverter & ECONAVI Technology
Optimum Performance while reducing Energy Usage
Panasonic inverter technology constantly adjusts its compressor rotation speed to provide maximum performance at all times. This precise operation enables quick cooling or heating while reducing power consumption compared to conventional non-inverter units.
Reduces Electricity Consumption
Panasonic inverter air conditioners/heat pumps are designed to give you exceptional energy savings while ensuring you stay comfortable at all times.
Constant Comfort
Precise temperature control with a wide power output range enables an inverter air conditioner to meet different room occupancy levels, providing constant comfort.
Quick Cooling and Heating
Panasonic Inverter air conditioners can operate with higher cooling/heating power during the start-up period to cool/heat the room faster than non-inverter models.
Whisper Quiet Operation
The indoor operating noise has been reduced by 5dB as the Inverter constantly varies its output power to enable more precise temperature control.
What’s ECONAVI?
High-precision sensor technology allows efficient, automatic operation to match room conditions. This keeps everyone comfortable while saving energy.
What does ECONAVI detect?
Wider Output Power Range
Minimum Capacity
Rated Capacity
8,700Btu/h
Maximum Capacity
12,000Btu/h
Human Activity Sensor
2,800Btu/h
• Level of activity.
• Human presence.
• Changes in human location.
• Changes in human activity.
• Changes in human presence.
• Adjusts airflow direction.
• Low activity: Auto increase set temperature.
• Absence: Auto increase set temperature.
9
Advanced ECONAVI Technology
Energy Saving and Comfort Through Sensor Technology
ECONAVI 3 Sensors
1. Absence Detection
Reduces energy usage when no activity is detected.
Energy
Loss!
2. Activity Detection
When activity is detected, sensors start working to efficiently cool the zone.
Human Activity Sensor
Waste
Reduced!
Human Activity Sensor
Inverter & ECONAVI
Switches from high operation to reduce cooling.
Energy
Loss!
3. Area Search
Area Search is activated when activity detection is located in one side of the room vs. the other.
Energy
Loss!
Human Activity Sensor
Waste
Reduced!
Waste
Reduced!
Switches from high to mild cooling.
Sends cool air only to areas where people are.
10
Air Conditioners and Heat Pumps Line-Up
Your Best Choice in Mini Split Air Conditioning and Heat Pump Systems
Since 1983, Panasonic Mini Split Air Conditioner and Heat Pump products offer a wide range of versatile solutions for cooling and heating requirements for single or multiple rooms. The indoor unit (evaporator) is mounted inside a room and connected to the outdoor unit (condenser) via refrigerant lines and inter-unit wiring through a 3-1/2” opening in the wall. Since no ductwork is required, installation is simple, fast and efficient. Ducted models are also available.
The indoor unit has been uniquely designed to provide whisper-quiet operation while delivering comfort throughout the room. Panasonic
Model Chart
Mini Split Systems are stylish and provide the quality and reliability you can count on.
MULTI ZONE:
Indoor Unit
All Multi Zone Systems require a minimum 2 indoor units installed. When selecting Multi-Zone please consider System Capacity and Indoor Unit Combinations. See pages 35 and 36.
11
RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS
Zones 2 2 thru 3 2 thru 4 2 thru 5
System Btu/h 18,000 (1.5 TON) 19,000 (1.5 TON) 24,000 (2.0 TON) 36,000 (3.O TON)
SEER (Non-Ducted / Ducted) 19.0 / 19.0 22.0 / 18.5 22.0 / 19.0 18.5 / 16.5
HSPF (Non-Ducted / Ducted) 9.5 / 9.0 10.5 / 9.0 9.5 / 9.0 10.0 / 9.5
Outdoor Unit
Wal l M ou nt 5,000 Btu/h
Wa ll Mo un t
7,000 Btu/h
W al l Mo un t 9,000 Btu/h
W al l Mo u nt
12,000 Btu/h
W al l Mo u nt
18,000 Btu/h
W al l Mo u nt
24,000 Btu/h
4 -W a y C a ss e tt e
9,000 Btu/h
4 -W a y C a ss e tt e
12,000 Btu/h
4 -W a y C a ss e tt e
18,000 Btu/h
Slim Duct
5,000 Btu/h
Slim Duct
7,000 Btu/h
Slim Duct
9,000 Btu/h
Slim Duct
12,000 Btu/h
Slim Duct
18,000 Btu/h
Multi Split Heat Pumps
CU-2E18SBU-5 CU-3E19RBU-5 CU-4E24RBU-5 CU-5E36QBU-5
CS-ME5RKUA CS-ME5RKUA CS-ME5RKUA CS-ME5RKUA
CS-ME7RKUA CS-ME7RKUA CS-ME7RKUA CS-ME7RKUA
CS-E9RKUAW CS-E9RKUAW CS-E9RKUAW CS-E9RKUAW
CS-E12RKUAW CS-E12RKUAW CS-E12RKUAW CS-E12RKUAW
N/A CS-E18RKUAW CS-E18RKUAW CS-E18RKUAW
N/A N/A CS-E24RKUAW CS-E24RKUAW
CS-ME9SB4U CS-ME9SB4U CS-ME9SB4U CS-ME9SB4U
CS-E12RB4UW CS-E12RB4UW CS-E12RB4UW CS-E12RB4UW
N/A CS-E18RB4UW CS-E18RB4UW CS-E18RB4UW
CS-ME5SD3UA CS-ME5SD3UA CS-ME5SD3UA CS-ME5SD3UA
CS-ME7SD3UA CS-ME7SD3UA CS-ME7SD3UA CS-ME7SD3UA
CS-E9SD3UAW CS-E9SD3UAW CS-E9SD3UAW CS-E9SD3UAW
CS-E12SD3UAW CS-E12SD3UAW CS-E12SD3UAW CS-E12SD3UAW
N/A CS-E18SD3UAW CS-E18SD3UAW CS-E18SD3UAW
SINGLE ZONE:
RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS
Residential
System Btu/h 9,000 12,000 15,000 18,000 24,000
-15 Degree
-5 Degree
Pro Series
-4 Degree
4-Way Ceiling
5 Degree
Ducted
-5 Degree
Up To
30.6 SEER
14.0 HSPF
Up to
23.0 SEER
11.0 HSPF
Up to
16 SEER
8.5 HSPF
Up to
18.0 SEER
9.0 HSPF
Up to
20.5 SEER
10.0 HSPF
Outdoor Unit CU-XE9SKUA CU-XE12SKUA-1 CU-XE15SKUA-1 N/A N/A
Wall Mount use picture CS-XE9SKUA CS-XE9SKUA CS-XE12SKUA-1 CS-XE15SKUA-1 N/A N/A
Model Chart
Outdoor Unit CU-E9RKUA CU-E12RKUA N/A CU-E18RKUA CU-E24RKUA
Wall Mount Picture CS-E9RKUA CS-E9RKUAW CS-E12RKUAW N/A CS-E18RKUAW CS-E24RKUAW
Outdoor Unit CU-RE9SKUA CU-RE12SKUA N/A CU-RE18SKUA CU-RE24SKUA
Wall Mount Picture CS-RE9SKUA CS-RE9SKUA CS-RE12SKUA N/A CS-RE18SKUA CS-RE24SKUA
Outdoor Unit N/A CU-E12RB4U N/A CU-E18RB4U N/A
4-Way Cassette N/A CS-E12RB4UW N/A CS-E18RB4UW N/A
Outdoor Unit CU-E9SD3UA CU-E12SD3UA N/A CU-E18SD3UA N/A
Ducted CS-E9SD3UAW CS-E12SD3UAW N/A CS-E18SD3UAW N/A
System Btu/h 26,000 30,000 36,000 42,000
-4 Degree
-4 Degree
-4 Degree
-4 Degree
SINGLE SPLIT COOLING ONLY
up to
16.7 SEER
10.1 HSPF
up to
18.0 SEER
9.5 HSPF
up to
18.0 SEER
9.0 HSPF
up to
14.0 SEER
9.0 HSPF
Outdoor Unit U-26PE1U6 CU-KE30NKU CU-KE36NKU N/A
Wall Mount S-26PK2U6 CS-KE30NKU CS-KE36NKU N/A
Outdoor Unit U-26PE1U6 N/A U-36PE1U6 U-42PE1U6*
Ceiling Suspended S-26PT2U6 N/A S-36PT2U6 S-42PT2U6
Outdoor Unit U-26PE1U6 N/A U-36PE1U6 U-42PE1U6*
4-Way Cassette S-26PU2U6 N/A S-36PU2U6 S-42PU2U6
Outdoor Unit U-26PE1U6 N/A U-36PE1U6 N/A
Concealed Duct S-26PF2U6 N/A S-36PF2U6 N/A
Low Ambient
0 Degree
Representative product images shown here. See product page for actual model images. *See image of U-42PE1U6 double fan unit page 21.
16 SEER
Outdoor Unit N/A CU-KS30NKUA CU-KS36NKUA N/A
Wall Mount N/A CS-KS30NKU CS-KS36NKU N/A
12
Model Feature Chart
Features Chart
Wall Mounted
Ceiling
4-Way Cassette
Ducted
ECONAVI DUAL SENSOR
ECONAVI MONO SENSOR
Dry Mode
Blue Fin Condenser
Room Freeze Protection
Microprocessor-Controlled
Operation
Wireless Remote
Controller
Wired Remote Controller
Self-Diagnosing Function
5 Fan Speeds and
Automatic Fan Operation
Air Sweep Control
LOWAMBIENT COOLING ONLY
KS30NKUA KS36NKUA
XE9SKUA
XE12SKUA-1
XE15SKUA-1*
E9RKUA E12RKUA E18RKUA E24RKUA
RE9SKUA RE12SKUA RE18SKUA RE24SKUA
KE30NKU KE36NKU
HEAT PUMPS
E12RB4U E18RB4U
26PEK2U6
26PET2U6 36PET2U6 42PET2U6
26PEU2U6 36PEU2U6 42PEU2U6
26PEF2U6 36PEF2U6
E9SD3UAW E12SD3UAW E18SD3UAW
a
aa
Option Option Option Option
aaaaaaaaaaa
aaa a
a
aaaaaaaaaaa
aaaaaa
Option Option Option Option Option
Option Option Option
aaa
aa
Option Option
aaaaa a
aaaaaaaaaaa
aaaaaaaa a
Louver Control
Base Pan Heater
Automatic Heating and
Cooling Changeover
Hot Start Heating System
24-Hour Clock with
ON/OFF Program Timer
1-Hour OFF Timer
Weekly Timer
System Controller
Filter Sign
Automatic Restart Function
after Power Failure
Built-In Drain Pump
Low Ambient
Electric
Expansion
Valve
R-410A Refrigerant
Quiet Mode
3M/Anti-microbial Filter
aaaaaaaa a
a
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaaa
a a
Option Option Option Option
Option Option Option Option
Option Option Option
aaaa
aaa
Option
Option
aaaaaaaaaaa
a aaa
aaaaaaaaaaa
aaaaaaaaaaa
aaaaaaaaaaa
aaaaa aa
aa
13
Features
Flap
ECONAVI Dual/Mono sensor
Automatic sensor for energy efficiency and comfort. Adsence & Activity Detection, Area Search
Room Freeze Protection*
Room Freeze Protection mode helps prevent plumbing damage due to sub-Freezing Temperature. This mode automatically turns on the compressor for heat pump operation if the room temperature falls to about 46°F.
*This function may not be performed if the unit is not powered, or if the unit is unable to operate such as in protection mode. Please consult with the HVAC installers or professional for details.
Microprocessor-Controlled Operation
Microprocessor control ensures that the temperature and humidity levels in the room are always comfortable.
Wireless Remote Control
Panasonic’s infrared Remote Control with and easy-to-read LCD Display, gives the user the capability to adjust & set: temperature, sweep (louver control), fan speeds, timer and more, for complete automatic operation.
Automatic Heating and Cooling Changeover
After setting the temperature and functions you desire, just relax. If the room temperature is higher than the set temperature, cooling operation begins. If the room temperature is lower than the set temperature, heating operation begins. During normal thermostat cycle operation, cooling and heating operations automatically change in accordance with set temperature, time and room temperature (Single Zone Heat Pump unit only).
1-hour OFF Timer
When this button is pushed either while the unit is operating or while it is stopped, the unit will operate for one hour, then switch off automatically.
24-hour Clock with ON/OFF Program Timer
The remote control unit allows you to set a wide variety of timer-based operations. Such functions include automatic ON/OFF with a timer setting, same time ON/OFF every day, ON timer, OFF timer and Combination timer.
Automatic Restart Function after Power Failure
Filter Sign
Filter sign informs you when filter maintenance is necessary.
XE/E series with CZ-RDC516C-1
Self-Diagnosing Function
Units are equipped with Self-Diagnosing Function (methods are difference depending on the models). This makes it easier to diagnose malfunctions, greatly reducing service labor (Wired remote controller).
(Example of CZ-RTC2)
Anti-Microbial Filter
Anti-microbial Filter by 3M. This filter is treated to inhibit the growth of mold and mildew, and helps create clean air.
Features Chart
Dry Mode
By coupling compressor and fan operation, intermittent operation can be precisely controlled according to room temperature, so that air is efficiently dehumidified.
5 Fan Speeds and Automatic Fan Operation
Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low. According to room temperature to maintain a comfortable airflow throughout the room.
Air Sweep Control
The air sweep function moves the louver up and down in the air outlet, directing air in a “sweeping” motion around the room and providing comfort in every corner.
Cool/Dry Mode
Heat Mode
Base Pan Heater
Exterios XE models include a base pan heater that prevents freezing condensate and allows very low ambient operation.
Hot Start Heating System
Right from the start, air is warm and comfortable. The Hot Start Heating System prevents any cold blasts at the beginning while the heat pump is warming up (Heat pump unit only).
Built-In Drain Pump
Max. head 20 inches from the discharge of the indoor unit. Condensation pump is only for allowing drain line to meet minimum gravity flow requirements.
Low Ambient
Low Ambient heating operation models range from 5°F to -15°F
Electric Refrigerant Control Valve
The circulation volume of the refrigerant is controlled by a pulse type electric control valve. In order to attain optimum efficiency, when the power is switched ON, the opening degree of the electric control valve is controlled between 90 and 480 steps.
Quiet Mode
LOW, low fan speed for extra quiet operation.
Test Comparison
Microbial Growth Rating
7 days 28days
Anti-microbialFilter No growth No growth
Normal Filter Paper 60% growth 60% growth
*Tested per ASTM G21-96
Blue Fin Condenser
Condensers can take a beating from exposure to salty air, rain and other corrosive factors. Panasonic has extended the life of its condensers with an original anti-rust coating. Tested for 2,000 salt spray hours.
14
Premium Series Wall-Mount Heat Pump
Wireless
Controller
(Included)
XE9SKUA XE12SKUA-1 XE15SKUA-1
Indoor Unit
CS-XE9SKUA / CS-XE12SKUA-1 / CS-XE15SKUA-1
Wireless Controller (Included)
Wired Remote Controller (CZ-RD516C-1) (Optional)
Outdoor Unit
CU-XE9SKUA / CU-XE12SKUA-1 / CU-XE15SKUA-1
Wall Mounted Heat Pumps
(optional)(optional) (optional)
Wall Mount Heat Pumps
Model No.
Unit Model No.
Performance & Electrical Ratings
Capacity
Moisture Removal High Pints/H 1.3 2.3 2.70 Dry Air Flow High CFM 470 520 550 SEER Cooling 30.6 26.2 22.10 EER Cooling 17.05 14.7 12.50 HSPF Heating 14.0 12.5 12.00 Power Supply V, Phase, Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz Running Amps
Power Input
Base Pan Heater W 80 80 80 Fuse or Circuit Breaker
Features
Controls Microprocessor Microprocessor Microprocessor Low Ambient Control Equipped Equipped Equipped Wireless Controller Included Included Included Wired Remote Controller(optional) Fan Speeds 5 Speeds + Auto 5 Speeds + Auto 5 Speeds + Auto Timer 24-hr Program 24-hr Program 24-hr Program Air Deflection
Air Filter Washable + Anti Microbial Filter Washable + Anti Microbial Filter Washable + Anti Microbial Filter Refrigerant R-410A R-410A R-410A Refrigerant control Electric Expansion Valve Electric Expansion Valve Electric Expansion Valve Operation Sound
Refrigerant Piping
Refrigerant Pipe Length Elevation Difference*
Dimensions & Weight Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Height inches 11-5/8 27-3/8 11-5/8 27-3/8 11-5/8 27-3/8 Width inches 34-9/32 34-15/32 34-9/32 34-15/32 34-9/32 34-15/32 Depth inches 10-1/16 12-5/8 10-1/16 12-5/8 10-1/16 12-5/8 Net Weight Lbs. 24 97 24 97
Cooling Btu/h 8,700 (2,800–12,000) 11,500 (2,800–14,000) 15,000 (3,300–19,000) Heating Btu/h 10,900 (3,000–18,000) (10,600 at 17˚F) 12,500 (3,000–23,000) (12,500 at 17˚F) 17,200 (3,300–24,000) (18,200 at 17˚F)
Cooling A 2.4 / 2.7 3.7 / 4.1 5.7 / 6.3 Heating A 3.1 / 3.5 4.4 / 4.9 5.9 / 6.7 Cooling W 510 (150–850) 780 (150–1,050) 1.20k (250–1.90k) Heating W 670 (150–1,650) 950 (150–2,100) 1.30k (200–2.65k)
Capacity A 15 20 25
Horizontal Automatic Automatic Automatic Vertical Automatic Automatic Automatic
In (Hi / Me / Lo) dB-A 42 / 29 / 26 44 / 35 / 32 47 / 37 / 34 Outdoor (Hi) dB-A 48 49 55 Type Flare Flare Flare Discharge inches 1/4 1/4 1/4 Suction inches 3/8 1/2 1/2 Ft. Max. 65.6 Max. 65.6 Max. 65.6 Outdoor Above Ft. Max. 49.2 Max. 49.2 Max. 49.2 Outdoor Below Ft. Max. 49.2 Max. 49.2 Max. 49.2
Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
CS-XE9SKUA CU-XE9SKUA CS-XE12SKUA-1 CU-XE12SKUA-1 CS-XE15SKUA-1
XE9SKUA XE12SKU-1
CZ-RD516C-1 CZ-RD516C-1 CZ-RD516C-1
XE15SKUA-1
24 106
Important: You must use refrigerant piping rated for R410a.
CU-XE15SKUA-1
15
ECONAVI Dual Sensor
ECONAVI Mono Sensor
Room Freeze Protection
Micro­processor Control
Wireless Controller
Wired Controller
Self Diagnose
5 Fan
Dry
speeds
Air sweep
Louver
Base Pan Heater
Auto­change over
Hot Start
24hr timer
Loading...
+ 36 hidden pages