-2-
PRECAUTIONS
• Do not block the ventilation slots.
Place the colour monitor at least 5 cm apart from the
wall.
• Do not expose the monitor to water or moisture.
Do not operate the monitor if it becomes wet. Turn
power off and ask a qualified service person for servicing. Moisture can damage the monitor and also create
the danger of electric shock.
• Do not attempt to disassemble the monitor. To prevent
electric shock, do not remove screws or cover. There
are no user-serviceable parts inside. Ask a qualified
service person for servicing.
• Use the appliance under conditions where temperature
is from
−10°C to +50°C (14°F to 122°F), and humidity
is below 90%.
The input power resource is 220 - 240V AC 50 Hz.
Do not operate the appliance under extreme ambient
conditions beyond the specified temperature, humidity,
or power resource ratings.
• This model is not produced for rack mounting.
• If more than two appliances are used, do not place
them less than 15 cm apart. Otherwise, the appliances
may produce noise on the display screen.
• Place the appliance at least 5 cm apart from the wall.
• Do not use it in a car or other places where it may be
exposed to severe vibration.
• Do not stack two or more sets.
PREFACE
The Panasonic WV-CM146 Colour Monitor is designed for
use with specified Colour CCTV Cameras.
Up to eight cameras can be connected to this monitor. The
sequential switching or quad video for these cameras is
available.
IMPORTANT NOTICE
1. The playback picture of a time lapse VTR in linear
mode may be disturbed by another channel picture. In
this case, the picture of other channel may be displayed or playback the VTR other than in linear mode.
2. The WV-CM146 has no compatibility with the WJ-FS10.
The WV-CM146 can playback recorded tapes using
the WJ-FS20 without VITC signal.
The WJ-FS20 can not playback recorded tapes using
the WV-CM146.
3. This operating instructions explains the operating procedures for using the monitor with the time lapse VTR;
AG-6730, AG-6740, AG-6760 or equivalent.
FEATURES
• Up to 8 solid state colour cameras can be connected
to Colour Monitor WV-CM146 with an alarm feature. (4
VP multiplexed cameras and 4 specified system cameras or 8 specified system cameras)
• The display of the monitor is divided into four screens
(quad monitor) to monitor the pictures of four cameras.
If eight cameras are connected, two quad pages are
displayed alternately by switching.
• Each camera picture is recorded (as frame) sequentially if time lapse VTR is connected.
• Alarm control output is supplied for a buzzer or chime.
• Alarm period is selectable from 1, 5, 10, 20, 30, 40, 50
or 60 seconds.
• Built-in protection circuit for any misconnection.
• STANDBY mode for no picture on the monitor during
sequential switching.
• Monitor has a 14" diagonal screen (13" diagonal actual
visual size)
• Sequential switching interval is selectable from 1, 2, 3,
4, 5, 6, 7, 8, 9, 10, 15, 20, 25 or 30 seconds.
• A CCTV camera with a microphone can be connected
to this monitor.
• VTR playback picture can be observed both in quad
mode and spot monitoring.
• Reset input for alarm function from time lapse VTR.
• Automatic bypass circuit for skipping no camera connection.
• Built-in Automatic Reset Function for Spot Monitor
Control Input. An automatic reset time of approx. 60
seconds is preset.
• The following functions are available by using the
setup menu:
• Camera Identification Display
• Audio Selection
• Timing Selection
• SEQ Time Adjustment (SEQ mode)
• PAGE SEQ (Quad mode)
• Alarm REC Mode
• Alarm Buzzer Setting
• Alarm Time Adjustment
• Automatic Resetting
• Bright Compensation Setting