Panasonic WV-BP120 User Manual

CCTV Cameras
WV-BP120/WV-BP124
Before attempting to connect or operate this product,
please read these instructions completely.
WV-BP120
WV-BP124
(Lens : option)
CAUTION
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK), NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol, within an equilateral triangle, is interned to alert the user to the presence of uninsulat­ed "dangerous voltage" within the product's enclosure that may be of sufficient magni­tude to constitute a risk of electric shock to persons.
The serial number of this product may be found on the top of the unit. You should note the serial number of this unit in the space provided and retain this book as a permanent record of your purchase to aid identification in the event of theft.
Model No. Serial No.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and main­tenance (servicing) instructions in the litera­ture accompanying the appliance.
WARNING:
TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
ENGLISH VERSION
For U.K.
FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT CARE­FULLY.
This appliance is supplied with a moulded three pin mains plug for your safety and convenience. A 13 amp fuse is fitted in this plug. Should the fuse need to be replaced please ensure that the replacement fuse has a rating of 13 amp and that it is approved by ASTA or BSI to BS1362. Check for the ASTA mark
H or the BSI mark G on the body of the fuse.
If the plug contains a removable fuse cover you must ensure that it is refit­ted when the fuse is replaced. If you lose the fuse cover the plug must not be used until a replacement cover is obtained. A replacement fuse cover can be purchased from your local Panasonic Dealer.
IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE SOCKET OUTLET IN YOUR HOME THEN THE FUSE SHOULD BE REMOVED AND THE PLUG CUT OFF AND DISPOSED OF SAFELY. THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE CUT OFF PLUG IS INSERTED INTO ANY 13 AMP SOCKET.
If a new plug is to be fitted please observe the wiring code as shown below. If in any doubt please consult a qualified electrician.
WARNING: This apparatus must be earthed.
-1-
We declare under our sole responsibility that the product to which this declaration relates is in conformity with the stan­dards or other normative documents following the provisions of Directive EEC/89/336.
Noi dichiariamo sotto nostra esclusiva responsabilità che il prodotto a cui si riferisce la presente dichiarazione risulta con­forme ai seguenti standard o altri documenti normativi conformi alle disposizioni della direttiva CEE/89/336.
Wij verklaren als enige aansprakelijke, dat het product waarop deze verklaring betrekking heeft, voldoet aan de volgende nor­men of andere normatiefve dokumenten, overeenkomstig de bepalingen van Richtlijn 89/336/EEC.
Vi erklærer os eneansvarlige for, at dette produkt, som denne deklaration omhandler, er i overensstemmelse med den følgende standarder eller andre normative dokumenter i følge bestemmelserne i direktiv 89/336/EEC.
Vi deklarerar härmed värt fulla ansvar för att den produkt till vilken denna deklaration hänvisar är i överensstämmelse med standarddokument, eller andra normativa dokument som framstölls i Direktiv 89/336/EEC.
Ilmoitamme yksinomaisella vastuullamme, että tuote, jota tämä ilmoitus koskee, noudattaa seuraavia standardeja tai muita ohjeellisia asiakirjoja, jotka noudattavat direktiivin 89/336/EEC. säädöksiä.
Vi erklærer oss alene ansvarlige for at produktet som denne erklæringen gjelder for, er i overensstemmelse med følgende normer eller andre normgivende dokumenter som fælger bestemmelsene i direktiv 89/336/EEC.
ENGLISH
IMPORTANT
The wires in this mains lead are coloured in accordance with the following code.
Green-and-yellow: Earth Blue: Neutral Brown: Live
As the colours of the wire in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows.
The wire which is coloured green-and-yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol
I or coloured green or green-and-yellow.
The wire which is coloured blue must be connected to the terminal in the plug which is marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal in the plug which is marked with the letter L or coloured red.
How to replace the fuse
Open the fuse compartment with a screwdriver and replace the fuse and fuse cover.
THIS APPARATUS MUST BE EARTHED.
To ensure safe operation the three-pin plug supplied must be inserted only into a standard three-pin power point which is effectively earthed through the normal household wiring. Extension cords used with the equipment must be three-core and be correctly wired to provide con­nection to earth. Wrongly wired extension cords are a major cause of fatalities. The fact that the equipment operates satisfactorily does not imply that the power point is earthed and that the installation is completely safe. For your safety, if in any doubt about the effective earthing of the power point, consult a qualified electrician.
For U.K.
For Australia
-2-
CONTENTS
PREFACE ...................................................................................................................................................................... 3
FEATURES .................................................................................................................................................................... 3
PRECAUTIONS ............................................................................................................................................................. 4
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ...................................................................................... 5
CONNECTIONS ............................................................................................................................................................ 8
LENSES ...................................................................................................................................................................... 10
FOCUS OR FLANGE-BACK ADJUSTMENT ............................................................................................................... 16
INSTALLATION OF CAMERA ..................................................................................................................................... 17
PREVENTION OF BLOOMING AND SMEAR ............................................................................................................. 17
LENS MAINTENANCE AND CLEANING .................................................................................................................... 17
SPECIFICATIONS ....................................................................................................................................................... 18
STANDARD ACCESSORIES ....................................................................................................................................... 19
OPTIONAL ACCESSORIES ........................................................................................................................................ 19
The model numbers listed in this Operating Instructions have no suffixed attached to it.
-3-

PREFACE

Panasonic's WV-BP120 series cameras introduce a new level of high picture quality through the use of a 1/3 inch interline transfer CCD having 512 horizontal pixels (picture elements). High performance-to-cost ratio is achieved through the use of newly developed Sync IC's and ability to shoot indoor scenes with a fixed iris lens by use of Electronic Light Control (ELC) function.

FEATURES

• Minimum illumination of 0.15 lx at F1.4 and Signal­to-noise ratio of 46 dB by employing a 1/3 inch interline transfer CCD image sensor with 512 (H) x 582 (V) pixels.
• 380 lines of horizontal resolution
• Either optional standard C-mount or Special C­mount (CS-mount) auto iris control lens can be used with.
• Selectable auto iris control signal for the lens either a video signal or DC control signal.
• Line-locked Sync or switchable Multiplexed Verti­cal Drive (VD2) automatically.
-4-

PRECAUTIONS

• Do not attempt to disassemble the camera.
To prevent electric shock, do not remove screws or cover. There are no user-serviceable parts inside. Refer servicing to qualified service personnel.
• Handle the camera with care.
Do not abuse the camera. Avoid striking or shak­ing it. The camera could be damaged by improper handling or storage.
• Do not expose the camera to rain or moisture, or try to operate it in wet areas.
Do take immediate action if ever the camera do becomes wet. Turn power off and refer servicing to qualified service personnel. Moisture can dam­age the camera and also create the danger of electric shock.
• Never face the camera toward the sun.
Whether the camera is in use or not, never face it toward the sun. Do use caution when operating the camera in the vicinity of spot lights or other bright lights and light reflecting objects.
• Do not operate the camera beyond its temperature, humidity or power source ratings.
Do not use the camera in an extreme environment where high temperature or high humidity exist. Use the camera under conditions where tempera­tures are within
10°C - +50°C (14°F - 122°F), and humidity is below 90%. The input power source is 220V - 240V AC 50 Hz for WV-BP120 or 24V AC 50 Hz for WV-BP124.
Loading...
+ 16 hidden pages