Installation Guide
Model Name Model No.
VL-SV71
Video Intercom System
VL-SV72
Main Monitor Station
R This guide is for use with the above 4 models.
Door station Main monitor station
R The Installation Guide in Indonesian can be accessed from the following site:
https://panasonic.net/cns/pcc/support/intercom/sv71
R Door station is described as "doorphone" and Main monitor station is described as "main
monitor" in this guide.
R In this guide, the suffix of each model number (e.g., the "BX" in "VL-SV71BX") is omitted
unless necessary.
Note to the installer
R Before attempting to connect or operate this product, please read the label on the rear of
the doorphone and the main monitor/extension monitor.
R Please read this guide carefully, and install the product safely and correctly by following
the instructions. Carefully read the information found in the section titled "For your
safety" in particular.
R Only use attachments/accessories specified by the manufacturer.
R The installation shall be carried out in accordance with all applicable installation rules.
R To the maximum extent permitted by law, Panasonic assumes no responsibility for
injuries or property damage resulting from failures arising out of improper installation
or operation inconsistent with this document.
R After installation, make sure to leave this guide with the customer.
VL-MV71
VL-MV72
Model No.

For your safety
To prevent severe injury and loss of life/
property, read this section carefully
before using the product to ensure
proper and safe operation of your
product.
WARNING
Preventing fire, electric shock and
short circuits
RLeave installation work to the
dealer. Installation work requires
technique and experiences. Failure
to observe this may cause fire,
electric shock, injury, or damage to
the product. Consult the dealer.
RElectrical connection work should
be performed by certified personnel
only. Certification is required for
performing electrical connection
work. Consult your dealer.
RUse only the specified power supply
unit and AC cable.
RDo not attempt to disassemble or
modify this product. Contact an
authorised service centre for repairs.
RNever install wiring during a lightning
storm.
RDo not connect non-specified devices.
RDo not connect a power cable to a
terminal that is not specified in this
guide.
RWhen opening holes in walls for
installation or wiring, or when securing
the power cable, make sure you do not
damage existing wiring and ductwork.
RDo not make any wiring connections
when the power supply is turned on.
RDo not use the supplied power supply
unit for outdoor installations (it is for
indoor use only).
RDo not install the main monitor/
extension monitor in the following
places:
– Places where the main monitor/
extension monitor may be splashed
with water or chemicals.
– Places where there is a high
concentration of dust, or high
humidity.
RDo not perform any actions (such as
fabricating, twisting, stretching,
bundling, forcibly bending, damaging,
altering, exposing to heat sources, or
placing heavy objects on the power
cable) that may damage the power
cable. Using the product with a
damaged power cable may cause
electric shock, short circuits, or fire.
Contact an authorised service centre
for repairs.
RWhen existing chime wires are used, it
is possible that they contain AC
voltage.
Contact an authorised service centre.
CAUTION
Preventing electric shock
RIf the wiring is underground, do not
make any connections underground.
RIf the wiring is underground, use a
protection tube.
RIf the wiring is outdoors, use a
protection tube or a surge protector.
Preventing injury
R Install the product securely adhering
to the instructions in this guide to
2

prevent it from falling off the wall.
Avoid installing onto low-strength
walls, such as gypsum board, ALC
(autoclaved lightweight concrete),
concrete block, or veneer (less than
18 mm thick) walls.
Supplied accessories for installation
For the doorphone
Screw × 2
(3.8 mm × 20 mm)
For the main monitor/extension monitor
Mounting bracket × 1
Power supply unit and related items
Power supply unit × 1
(VL-PS241)
Important:
R You will need the following additional items to install and configure the doorphone and the
main monitor/extension monitor.
[Locally procured]
– Power cables (AC/DC cables)
Prepare wires of the appropriate specification. (a"Wire type and length")
*1
Screw × 2
(4 mm × 16 mm)
*2
AC cable × 1 Screw × 2
*2
and wires (for doorphone and other connections):
Cable binder ×
1
(4 mm ×
40 mm)
Note:
R The illustrations in the supplied manual(s) may vary slightly from the actual product.
*1 VL-SV71/VL-SV72 models only
*2 VL-SV72/VL-MV72 models only
3

Precautions for installation
To avoid malfunction or communication disturbances, do not install the doorphone or the main monitor/
extension monitor in the following locations:
– Places where vibration or any other kind of impact occurs.
– Places where echoing is frequent.
– Places near a high concentration of dust, hydrogen sulphide, ammonia, sulphur, or noxious fumes.
For the doorphone
R If a strong light is shining on the doorphone, the visitor’s face may not be distinguishable. Do not place
the doorphone in the following locations:
– Where most of the background is the sky.
– Where the background is a white wall, and direct sunlight will reflect off it.
– Where direct sunlight will shine on the doorphone.
R Do not place the doorphone in locations where echoing occurs, as this will cause the doorphone to
beep frequently.
R Make sure the rear of the doorphone is not subject to water.
R Depending on the installation location, condensation may form on the doorphone’s lens cover. This
may cause images to become obscured. Condensation will dissipate as the temperature rises.
For the main monitor/extension monitor
R Leave at least 20 cm of space above, below, and to the left and right sides of the main monitor/
extension monitor. Do not install on a wall that is deeply recessed.
R Do not install the main monitor/extension monitor inside a wall.
R Be sure to install the main monitor/extension monitor more than 5 m away from the doorphone.
R In areas surrounded by a high electrical field, disturbances may occur in the main monitor’s/extension
monitor’s image or sound.
4

Wiring schematic diagram
Set up correctly according to the following wiring schematic diagram and "Wire type and length".
R For information, such as order numbers, about optional devices that can be connected to, refer to the
"Additional/replacement accessories" section in the Operating Instructions.
DOORPHONE 1 DOORPHONE 2
*1 *1
MAIN MONITOR
You can also connect an
optional lobby station or Video
D1
1
D2
2
D3
3
D4
4
5
Ml-1
6
Ml-2
7
MO-1
8
MO-2
9
MO-3
10
MO-4
11
MO-5
12
MO-6
13
IN1
14
IN2
15
IN3
16
IN4
17
P1
18
P2
19
20
21
22
24 V DC
POWER SUPPLY UNIT
S1
S2
S3
S4
NP
NP
NP
NP
NP
NP
NP
NP
NP
NP
NP
11
Electric
Electric
lock
lock
*3
Intercom System for Apartment
Complexes. (See page 7.)
EXTENSION
Ml-1
5
Ml-2
6
5
6
5
6
Connection device
for option Input
(A contact)
MONITOR 1
EXTENSION
Ml-1
Ml-2
MONITOR 2
EXTENSION
Ml-1
MONITOR 3
Ml-2
*2
Terminal box
(4-conductor
wiring)
PBX
NP: Non-polarised
A Power supply
*1 When you use an additional doorphone, the maximum number of the electric locks that can be
connected to the doorphone depends on the type of doorphone. Consult your dealer for further
information.
For VL-V554 users:
– Make sure to only connect electric door locks to the S1/S2 terminals of the doorphones.
*2 Connection devices for option input (A contact) can be used when a VL-V900 and VL-V700 series
Video Intercom System for Apartment Complexes is used.
– Make sure to connect emergency terminals to the IN1/IN2 terminals.
– Make sure to connect doorbells to the IN3/IN4 terminals. A doorbell and doorphone 2 cannot be
used together.
*3 VL-SV72/VL-MV72 only
5