Panasonic U-71PZH2R5, U-100PZH2R5, U-125PZH2R5, U-140PZH2R5, U-100PZH2R8 Operating Instructions

...
Type 71 Type 100, 125, 140
Model No.
OUTDOOR UNIT
Single Split (Single-phase) Type PZH2
U-71PZH2R5 U-100PZH2R5 U-125PZH2R5
U-140PZH2R5
Operating Instructions
Air Conditioner
U-100PZH2R8 U-125PZH2R8 U-140PZH2R8
Connectable indoor unit lineup
This booklet is the operating instructions for outdoor unit. Regarding the indoor unit, see the operating instructions supplied with the indoor unit.
INDOOR UNIT
4-Way Cassette Wall-Mounted
Ceiling
Low Silhouette Ducted Ducted
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
ACXF55-22950
Thank you for purchasing this Panasonic product. This product is a commercial air conditioner outdoor unit. Installation Instructions attached.
Contents
Safety Precautions
The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance:
Safety Precautions ........................................................... 2
z
Precautions for Use .........................................................5
z
Names of Parts ................................................................. 6
z
Specications ................................................................... 7
z
•Outdoor unit ...................................................................7
This symbol shows that this equipment uses a flammable refrigerant. If the
WARNING
CAUTION
CAUTION
CAUTION
refrigerant is leaked, together with an external ignition source, there is a possibility of ignition.
This symbol shows type of flammable refrigerant contained in the system.
This symbol shows that a service personnel should be handling this equipment with reference to the Technical Manual.
This symbol shows that there is information included in the Operating Instructions and/or Installation Instructions.
Product Information
If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate.
Model No.
Serial No.
Date of purchase
Dealer’s address
Phone number
Important Information Regarding The Refrigerant Used
This product contains uorinated greenhouse gases. Do not vent gases into the atmosphere.
Refrigerant type: R32
(1)
GWP
(1)
Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local dealer for more information.
value: 675
GWP = global warming potential
This symbol refers to a hazard or
WARNING
CAUTION
Prohibited matters
• Read these Operating Instructions carefully before using this air conditioner. If you still have any difculties or problems, consult your dealer for help.
• This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in these Operating Instructions.
unsafe practice which can result in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.
Matters to be observed
WARNING
Conrm to authorized dealer or specialist on usage of specied refrigerant type. Using of refrigerant other than the specied type may cause product damage, burst and injury etc.
This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case.
Never use or store gasoline or other ammable vapor or liquid near the air conditioner — it is very dangerous.
Do not use this appliance in a potentially explosive atmosphere.
Never touch the unit with wet hands.
Do not insert your ngers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.
2
WARNING
If the refrigerant comes in contact with a ame, it produces a toxic gas.
For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing.
Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency.
Dispose of according to national and/or local legislation.
This product must not be modied or disassembled under any circumstances. Modied or disassembled unit may cause re, electric shock or injury.
Do not clean inside the indoor and outdoor units by users. Engage authorized dealer or specialist for cleaning.
In case of malfunction of this appliance, do not repair by yourself. Contact the sales dealer or service dealer for a repair and disposal.
Provide a power outlet to be used exclusively for each unit, and a power supply disconnect, Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) for overcurrent protection should be provided in the exclusive line.
Provide a power outlet exclusively for each unit, and full disconnection means having a contact separation in all poles must be incorporated in the xed wiring in accordance with the wiring rules.
Do not use modied cord, joint cord, extension cord or unspecied cord to prevent overheating and re.
The appliance shall be stored in a room without continuously operating ignition sources (for example: open ames, an operating gas appliance or an operating electric heater).
Be aware that refrigerants may not contain an odour.
An unventilated area where the appliance using ammable refrigerants is installed shall be so constructed that should any refrigerant leak, it will not stagnate so as to create a re or explosion hazard.
The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specied for operation.
After the unit is installed, never fail to ask the installer for the oor space of the room where the unit is installed and the refrigerant charge amount.
In case the unit or the room divider is changed, never fail to consult the sales dealer or service dealer.
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
Do not pierce or burn. In cases that require mechanical
ventilation, ventilation openings shall be kept clear of obstruction.
To prevent possible hazards from insulation failure, the unit must be grounded.
3
WARNING
The appliance shall be stored in a room without continuously operating open ames (for example: an operating gas appliance) and ignition sources (for example: an operating electric heater).
Stop using the product when any abnormality/failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/re/electric shock)
Examples of abnormality/failure:
• The ELCB trips frequently.
• The product sometimes does not start when turned on.
• The power is sometimes disconnected when the cord is moved.
• Burnt odor or abnormal noise is detected during operation.
• The body is deformed or abnormally hot.
• Water leaks from the indoor unit.
• Power cord or plug becomes abnormally hot.
• Fan speed cannot be controlled.
• The unit stops running immediately even if it is switched on for operation.
• The fan does not stop even if the operation is stopped.
Contact immediately your local dealer for maintenance/repair.
CAUTION
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Keep the re alarm and the air outlet at least 1.5m away from the unit.
Do not cool or heat the room too much if babies or invalids are present.
Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button.
Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed.
Do not touch the air inlet or the sharp aluminum ns of the outdoor unit. You may get injured.
Do not stick any object into the FAN CASE. You may be injured and the unit may be damaged.
Do not sit or step on the unit. You may fall down accidentally.
NOTICE
• The appliance shall be stored so as to prevent mechanical damage from occurring.
• The compressor may occasionally stop during thunderstorms. This is not a mechanical failure. The unit automatically recovers after a few minutes.
4
Precautions for Use
Installation
This air conditioner must be installed properly by qualied
z
installation technicians in accordance with the Installation Instructions provided with the unit. Before installation, check that the voltage of the electric
z
supply in your home or ofce is the same as the voltage shown on the nameplate.
WARNING
Avoid the following locations for installation.
Locations where smoke or combustible gas exists.
z
Also locations of extremely high temperature such as a greenhouse. Locations where excessively high heat-generating
z
objects are placed.
Attention:
Avoid installing the outdoor unit where salty sea water can
z
splash directly onto it or in sulphurous air near a spa. (To protect the air conditioner from heavy corrosion)
Wiring
All wiring must conform to the local electrical codes.
z
(Consult your dealer or a qualied electrician for details.) Each unit must be properly grounded with a ground (or
z
earth) wire or through the supply wiring. Wiring must be done by a qualied electrician.
z
Information for Users on Collection and Disposal of Old Equipment and Used Batteries
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved.
Pb
Operation Preparation
Turn the power mains on 5 hours before the start of operation.
(For warm-up)
Leave the power mains ON for continuous use.
z
NOTE
Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time.
ON
5
Names of Parts
OUTDOOR UNIT
Air intake
Air outlet
Type 71 Type 100, 125, 140
Wireless Remote Controller
Model No.
CZ-RWS3
Model No. CZ-RWSK2
Single Split
(Type PZH2)
Air outlet
Optional
Timer Remote Controller
Model No.
CZ-RTC4
Air intake
High-spec Wired Remote Controller
Model No.
CZ-RTC5B
For all indoor units
A
(Infrared Remote Controller)
Operation
Refer to the Operating Instructions attached to the optional Remote Controller.
AdjustingAirowDirection
Refer to the Operating Instructions attached to the indoor unit and optional Remote Controller.
Maintenance
Refer to the Operating Instructions attached to the indoor unit.
Troubleshooting
Refer to the Operating Instructions attached to the indoor unit.
Read the Operating Instructions included with the Remote Controller.
For all indoor units
6
Specications
Outdoor unit
Single Split Outdoor Unit (R32)
Model Name
Power source 230 - 240 V~ 50 Hz
Cooling capacity
Heating capacity
Sound Pressure level
(Cooling / Heating)
Sound Power level (Cooling / Heating)
Unit Dimensions (H×W×D)
Net weight
Model Name
Power source 400 - 415 V 3N~ 50 Hz
Cooling capacity
Heating capacity
Sound Pressure level
(Cooling / Heating)
kW
BTU/h
kW
BTU/h
dB(A)
dB(A)
mm
kg
kW
BTU/h
kW
BTU/h
dB(A)
U-71PZH2R5 U-100PZH2R5 U-125PZH2R5 U-140PZH2R5
7.1 10.0 12.5 14.0
24,200 34,100 42,700 47,800
8.0 11.2 14.0 16.0
27,300 38,200 47,800 54,600
48 / 50 52 / 52 53 / 53 54 / 54
64 / 66 68 / 68 69 / 69 70 / 70
996×940×340 1,416×940×340 1,416×940×340 1,416×940×340
68 99 99 99
U-100PZH2R8 U-125PZH2R8 U-140PZH2R8
10.0 12.5 14.0
34,100 42,700 47,800
11.2 14.0 16.0
38,200 47,800 54,600
52 / 52 53 / 53 54 / 54
Sound Power level (Cooling / Heating)
Unit Dimensions (H×W×D)
Net weight
Operation condition temperature range
•Coolingmode:-15°C~46°CDB
•Heatingmode:-20°C~24°CDB
Rated conditions Cooling : Indoor intake air temp. 27°C DB / 19°C WB. Outdoor intake air temp. 35°C DB. Heating : Indoor intake air temp. 20°C DB. Outdoor intake air temp. 7°C DB / 6°C WB.
dB(A)
mm
kg
68 / 68 69 / 69 70 / 70
1,416×940×340 1,416×940×340 1,416×940×340
99 99 99
7
© Panasonic Corporation 2018
Printed in China
Panasonic Corporation
http://www.panasonic.com
ACXF55-22950
DC1218-0
Loading...