Including pedestal44.7 ” × 27.0 ” × 13.0 ” (1,134 mm × 686 mm × 330 mm) (TH-42PX77U)
TV Set only44.7 ” × 25.3 ” × 3.92 ” (1,134 mm × 641 mm × 99.5 mm)
Weight
Including pedestal77.2 lb. (35 kg) (TH-42PX77U)
TV Set only61.8 lb. (28 kg) (TH-42PX77U)
Note:
·
· Design and Specifications are subject to change without notice. Weigh t and Dimensions shown are approximate.
· ·
CLOSED CAPTIONV-Chip
Photo ViewerHDAVI Control 2
44.7 ” × 27.0 ” × 12.7 ” (1,134 mm × 686 mm × 321 mm) (TH-42PE77U)
66.2 lb. (30 kg) (TH-42PE77U)
60.7 lb. (27.5 kg) (TH-42PE77U)
CONTENTS
Page Page
1 Applicable signals 4
2 Safety Precautions
2.1. General Guidelines
3 Prevention of Electro Static Discharge (ESD) to
Electrostatically Sensitive (ES) Devices
4 About lead free solder (PbF)
5 Service Hint
6 Plasma panel replacement method
6.1. Remove the rear cover
6.2. Remove the rear terminal cover
6.3. Remove the P-Board
6.4. Remove the Tuner unit
6.5. Remove the A-Board
6.6. Remove the side AV unit and the side AV bracket.
6.7. Remove the G-Board and GS-Board
6.8. Remove the D-Board
6.9. Remove the SU-Board
6.10. Remove the SD-Board
6.11. Remove the SC-Board
6.12. Remove the SS-Board
6.13. Remove the C1-Board
6.14. Remove the C2-Board
6.15. Remove the speaker L, R
6.16. Remove the stand brackets
6.17. Remove the Plasma panel section from the Cabinet assy
(glass)
6.18. Remove the K-Board and the S-Board
6.19. Replace the plasma panel (finished)
7 Caution statement
7.1. Caution statement.
8 Location of Lead Wiring
10
11
11
11
11
12
12
12
12
12
13
13
14
15
15
16
8.1. Lead of Wiring (1)
5
5
6
7
8
9
9
9
9
9
9
9
8.2. Lead of Wiring (2)
8.3. Lead of Wiring (3)
8.4. Lead of Wiring (4)
8.5. Lead of Wiring (5)
8.6. Lead of Wiring (6)
9 Self-check Function
9.1. Check of the IIC bus lines
9.2. Power LED Blinking timing chart
9.3. No Power
9.4. No Picture
9.5. Local screen failure
10 Service Mode
10.1. How to enter into Service Mode
10.2. Service tool mode
11 Adjustment Procedure
11.1. Driver Set-up
11.2. Initialization Pulse Adjust
11.3. P.C.B. (Printed Circuit Board) exchange
11.4. Adjustment Volume Location
11.5. Test Point Location
12 Adjustment
12.1. White balance adjustment
13 Hotel mode
14 Conductor Views
14.1. P-Board
14.2. G, GS, K and S-Board
14.3. A-Board
14.4. D-Board
14.5. C1-Board
14.6. C2-Board
16
17
18
19
20
21
22
22
23
24
25
26
27
27
29
30
30
31
31
32
32
33
33
35
37
37
40
41
44
46
47
2
14.7. SC-Board 48
14.8. SU-Board
14.9. SD-Board
14.10. SS-Bo ard
15 Schematic and Block Diagram
15.1. Schematic Diagram Note
15.2. Main Block Diagram
15.3. P-Board Block Diagram
15.4. P-Board (1 of 6) Schematic Diagram
15.5. P-Board (2 of 6) Schematic Diagram
15.6. P-Board (3 of 6) Schematic Diagram
15.7. P-Board (4 of 6) Schematic Diagram
15.8. P-Board (5 of 6) Schematic Diagram
15.9. P-Board (6 of 6) Schematic Diagram
15.10. G, GS, K and S-Board Block and Schematic Diagram
15.11. A-Boa rd (1 of 5) Block Diagram
15.12. A-Boa rd (2 of 5) Block Diagram
15.13. A-Boa rd (3 of 5) Block Diagram
15.14. A-Boa rd (4 of 5) Block Diagram
15.15. A-Boa rd (5 of 5) Block Diagram
15.16. A-Boa rd (1 of 12) Schematic Diagram
15.17. A-Boa rd (2 of 12) Schematic Diagram
15.18. A-Boa rd (3 of 12) Schematic Diagram
15.19. A-Boa rd (4 of 12) Schematic Diagram
15.20. A-Boa rd (5 of 12) Schematic Diagram
15.21. A-Boa rd (6 of 12) Schematic Diagram
15.22. A-Boa rd (7 of 12) Schematic Diagram
15.23. A-Boa rd (8 of 12) Schematic Diagram
15.24. A-Boa rd (9 of 12) Schematic Diagram
15.25. A-Boa rd (10 of 12) Schematic Diagram
15.26. A-Boa rd (11 of 12) Schematic Diagram
15.27. A-Boa rd (12 of 12) Schematic Diagram
51
52
53
55
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
15.28. D-Boa rd Block Diagram
15.29. D-Boa rd (1 of 6) Schematic Diagram
15.30. D-Boa rd (2 of 6) Schematic Diagram
15.31. D-Boa rd (3 of 6) Schematic Diagram
15.32. D-Boa rd (4 of 6) Schematic Diagram
15.33. D-Boa rd (5 of 6) Schematic Diagram
15.34. D-Boa rd (6 of 6) Schematic Diagram
15.35. C1 and C2-Board Block Diagra m
15.36. C1-Bo ard (1 of 2) Schematic Diagram
15.37. C1-Bo ard (2 of 2) Schematic Diagram
15.38. C2-Bo ard (1 of 2) Schematic Diagram
15.39. C2-Bo ard (2 of 2) Schematic Diagram
15.40. SC, SU and SD-Bo ard Block Diagram
15.41. SC-Bo ard (1 of 2) Schematic Diagram
15.42. SC-Bo ard (2 of 2) Schematic Diagram
15.43. SU-Bo ard (1 of 2) Schematic Diagram
15.44. SU-Bo ard (2 of 2) Schematic Diagram
15.45. SD-Bo ard (1 of 2) Schematic Diagram
15.46. SD-Bo ard (2 of 2) Schematic Diagram
15.47. SS-Bo ard Block Diagram
15.48. SS-Bo ard (1 of 2) Schematic Diagram
15.49. SS-Bo ard (2 of 2) Schematic Diagram
16 Exploded Views & Replacement Parts List
16.1. Exploded Views
16.2. Packing Exploded Views (Accessories box)
16.3. Replacement Parts List Notes
16.4. Mechanical Replacement Parts List (PDP TV)
16.5. Mechanical Replacement Parts List (Stand)
16.6. Electrical Replacement Parts List
80
TH-42PX77U / TH-42PE77U
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
105
105
106
107
108
109
110
3
TH-42PX77U / TH-42PE77U
1 Applicable signals
4
TH-42PX77U / TH-42PE77U
2 Safety Precautions
2.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
2.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between
1Mohm and 5.2Mohm.
When the exposed metal does not have a return path to
the chassis, the reading must be
Figure 1
.
2.1.2. Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5kohm, 10 watts resistor, in parallel with a
0.15µF capacitors, between each exposed metallic part on
the set and a good earth ground such as a water pipe, as
shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliamp. In case a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the
customer.
5
TH-42PX77U / TH-42PE77U
3 Prevention of Electro Static Discharge (ESD) to
Electrostatically Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called
Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor "chip" components. The following techniques should be used to help reduce the incidence of component damage
caused by electro static discharge (ESD).
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as
aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4. Use only an anti-static solder removal device. Some solder removal devices not classified as "anti-static (ESD protected)" can
generate electrical charge sufficient to damage ES devices.
5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable
conductive material).
7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
Caution
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise ham less motion such as the brushing
together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD) sufficient to
damage an ES device).
6
TH-42PX77U / TH-42PE77U
4 About lead free solder (PbF)
Note: Lead is listed as (Pb) in the periodic table of elements.
In the information below, Pb will refer to Lead solder, and PbF will refer to Lead Free Solder.
The Lead Free Solder used in our manufacturing process and discussed below is (Sn+Ag+Cu).
That is Tin (Sn), Silver (Ag) and Copper (Cu) although other types are available.
This model uses Pb Free solder in it’s manufacture due to environmental conservation issues. For service and repair work, we’d
suggest the use of Pb free solder as well, although Pb solder may be used.
PCBs manufactured using lead free solder will have the PbF within a leaf Symbol PbF stamped on the back of PCB.
Caution
·
· Pb free solder has a higher melting point than standard solder. Typically the melting point is 50 ~ 70 °F (30~40 °C) higher.
· ·
Please use a high temperature soldering iron and set it to 700 ± 20 °F (370 ± 10 °C).
·
· Pb free solder will tend to splash when heated too high (about 1100 °F or 600 °C).
· ·
If you must use Pb solder, please completely remove all of the Pb free solder on the pins or solder area before applying Pb
solder. If this is not practical, be sure to heat the Pb free solder until it melts, before applying Pb solder.
·
· After applying PbF solder to double layered boards, please check the component side for excess solder which may flow onto
· ·
the opposite side. (see figure below)
Suggested Pb free solder
There are several kinds of Pb free solder available for purchase. This product uses Sn+Ag+Cu (tin, silver, copper) solder.
However, Sn+Cu (tin, copper), Sn+Zn+Bi (tin, zinc, bismuth) solder can also be used.
Speaker out, Sound Processor
AV Terminal, AV Switch
Digital Signal Processor, Microcomputer
HDMI Interface, Peaks Lite 2
KRemote receiver, Power LEDGSSD Card Slot
SPower SwitchGKey Switch, Side Terminal
C1Data Driver (Lower Right)
C2Data Driver (Lower Left)
SCScan Drive
SUScan out (Upper)
SDScan out (Lower)
SSSustain Drive
8
6 Plasma panel replacement method
TH-42PX77U / TH-42PE77U
6.1. Remove the rear cover
1. See Service Hint (Section 5)
6.2. Remove the rear terminal
cover
1. Remove the screws (×8).
2. Remove the rear terminal cover.
6.3. Remove the P-Board
6.4. Remove the Tuner unit
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (A1, A5, A6, A7, A12, A51 and
A52).
3. Remove the screws (×2
4. Remove the screws (×4
) and remove the tuner cover.
) and remove the tuner unit.
Caution:
To remove P.C.B. wait 1 minute after power was off for
discharge from electrolysis capacitors.
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (P2, P6, P7, P9, P11, P12 and
P25).
3. Remove the screws (×8
) and remove the P-Board.
6.5. Remove the A-Board
1. Remove the tuner unit. (See section 6.4.)
2. Remove the screws (×6
) and remove the A-Board.
6.6. Remove the side AV unit and
the side AV bracket.
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (G51 and GS52) and relay
connector.
3. Remove the screws (×4
4. Remove the side AV unit.
9
).
TH-42PX77U / TH-42PE77U
5. Remove the screw (×1).
6.7. Remove the G-Board and GSBoard
1. Remove the side AV unit and the side AV bracket. (See
section 6.6.)
2. Remove the screws (×2
3. Remove the screws (×6) and remove the side AV unit
shield cover and the control button.
).
6. Remove the tabs (×4) and Remove the side AV bracket.
4. Remove the screws (×4) and remove the G-Board and
GS-Board.
10
6.8. Remove the D-Board
TH-42PX77U / TH-42PE77U
6.10. Remove the SD-Board
1. Remove the tuner unit. (See section 6.4.)
2. Disconnect the connectors (D5 and D25).
3. Disconnect the flexible cables (D20, D31 and D32).
4. Remove the screws (×4
) and remove the D-Board.
1. Remove the side AV unit and the side AV bracket. (See
section 6.6.)
2. Remove the screws (×2
3. Remove the flexible cables (SD1, SD2, SD3 and SD4)
connected to the SD-Board and remove the bridge
connector (SC46-SD46).
4. Slide the SD-Board to the left to disconnect from a
connector (SC42-SD42) on the SC-Board and remove the
SD-Board.
).
6.9. Remove the SU-Board
1. Remove the screws (×2).
2. Remove the flexible cables (SU1, SU2, SU3 and SU4)
connected to the SU-Board and remove the bridge
connector (SC45-SU45).
3. Slide the SU-Board to the left to disconnect from a
connector (SC41-SU41) on the SC-Board and remove the
SU-Board.
6.11. Remove the SC-Board
1. Remove the SU-Board and SD-Board. (See section 6.9.
and 6.10.)
2. Unlock the cable clampers to free the cable.
3. Disconnect the connector (SC2).
4. Disconnect the flexible cable (SC20).
5. Remove the screws (×6
) and remove the SC-Board.
11
TH-42PX77U / TH-42PE77U
6.12. Remove the SS-Board
6.14. Remove the C2-Board
1. Disconnect the connectors (SS11, SS12 and SS23).
2. Disconnect the flexible cables (SS53A, SS54A, SS55A and
SS56A).
3. Remove a short-jumper connector SS34 and re-use for new
SS-Board.
4. Remove the screws (×6
) and remove the SS-Board.
1. Remove the tuner unit. (See section 6.4.)
2. Unlock the cable clampers to free the cable.
3. Remove the flexible cables holder fastening screws (×8
).
4. Disconnect the flexible cables (CB5, CB6, CB7 and CB8).
5. Disconnect the flexible cables (C20 and C21).
6. Disconnect the connector (C23).
7. Remove the screws (×4
) and remove the C2-Board.
6.15. Remove the speaker L, R
1. Disconnect the relay connector .
2. Remove the screws (×4
holder.
3. Remove the speaker L, R.
each) and remove the speaker
6.13. Remove the C1-Board
1. Remove the tuner unit. (See section 6.4.)
2. Unlock the cable clampers to free the cable.
3. Remove the flexible cables holder fastening screws (×8
).
4. Disconnect the flexible cables (CB1, CB2, CB3 and CB4).
5. Disconnect the flexible cables (C10 and C11).
6. Remove the screws (×4
) and remove the C1-Board.
6.16. Remove the stand brackets
1. Remove the plasma panel section from the servicing stand
and lay on a flat surface such as a table (covered) with the
plasma panel surface facing downward.
2. Remove the stand brackets (left, right) fastening screws (×5
each) and remove the stand brackets (left, right).
12
6.17. Remove the Plasma panel
section from the Cabinet assy
(glass)
1. Remove the plasma panel section from the servicing stand
and lay on a fiat surface such as a table (covered) with the
plasma panel surface facing downward.
2. Remove the stand brackets (left, right) fastening screws (×2
each).
TH-42PX77U / TH-42PE77U
5. For leaving the plasma panel from the cabinet assy, pull the
bottom of the front frame forward, lift, and remove.
6.18. Remove the K-Board and the
S-Board
1. Remove the cabinet assy. (See section 6.17.)
2. Remove the screws (×14
bottom.
) and remove the glass holder
3. Replace the servicing stand and stand the set.
4. Remove the cabinet assy and the plasma panel fastening
screws (×13
).
3. Unlock the cable clampers to free the cable.
4. Remove the screws (×2
metal.
5. Remove the screws (×2).
13
) and remove the front P.C.B.
TH-42PX77U / TH-42PE77U
6. Disconnect the connector (S2) and Remove the S-Board.
7. Remove the screws (×2).
8. Disconnect the connectors (K1 and K2) and remove the KBoard.
6.19. Replace the plasma panel
(finished)
1. Place the new plasma panel (finished) on the flat surface of
the table (covered by a soft cloth), with the plasma panel
surface facing downward.
2. Attach the C1-Board and the C2-Board, connect the flexible
cables (×16) from the Plasma panel to the C1-Board and
the C2-Board, and fit the flexible cable holders.
3. Attach the Hooks (left, right) and fit the stand brackets (L,
R) to the new plasma panel.
4. Place the plasma panel section on the servicing stand.
5. Attach the cabinet assy and each P.C.Board and so on, to
the new plasma panel.
*When fitting the front frame, be careful to allow any
debris, dust or handling residue to remain between the
front glass and plasma panel.
14
7 Caution statement
7.1. Caution statement.
Caution:
Please confirm that all flexible cables are assembled correctly.
Also make sure that they are locked in the connectors.
Verify by giving the flexible cables a very slight pull.
TH-42PX77U / TH-42PE77U
15
TH-42PX77U / TH-42PE77U
8 Location of Lead Wiring
8.1. Lead of Wiring (1)
16
8.2. Lead of Wiring (2)
TH-42PX77U / TH-42PE77U
17
TH-42PX77U / TH-42PE77U
8.3. Lead of Wiring (3)
18
8.4. Lead of Wiring (4)
TH-42PX77U / TH-42PE77U
19
TH-42PX77U / TH-42PE77U
8.5. Lead of Wiring (5)
20
8.6. Lead of Wiring (6)
TH-42PX77U / TH-42PE77U
21
TH-42PX77U / TH-42PE77U
9 Self-check Function
Use the self-check function to test the unit.
1. Checking the IIC bus lines
2. Power LED Blinking timing
9.1. Check of the IIC bus lines
9.1.1. How to access
Self-check indication only:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [OK] button on the remote control
for more than 3 seconds.
Self-check indication and forced to factory shipment setting:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [MENU] button on the remote
control for more than 3 seconds.
9.1.2. Screen display
9.1.3. Check Point
Confirm the following parts if NG was displayed.
9.1.4. Exit
Disconnect the AC cord from wall outlet.
22
TH-42PX77U / TH-42PE77U
9.2. Power LED Blinking timing chart
1. Subject
Information of LED Flashing timing chart.
2. Contents
When an abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the
defective block can be identified by the number of blinks of the Power LED on the front panel of the unit.
23
TH-42PX77U / TH-42PE77U
9.3. No Power
First check point
There are following 2 states of No Power indication by power LED.
1. No lit
2. Red is lit then turns red blinking a few seconds later. (See 9.2.)
24
9.4. No Picture
TH-42PX77U / TH-42PE77U
25
TH-42PX77U / TH-42PE77U
9.5. Local screen failure
Plasma display may have local area failure on the screen. Fig-1 is the possible defect P.C.B. for each local area.
Fig-1
26
TH-42PX77U / TH-42PE77U
10 Service Mode
10.1. How to enter into Service Mode
While pressing [VOLUME ( - )] button of the main unit, press [RECALL] button of the remote control three times within 3
seconds.
10.1.1. Key command
“1” button...Main items Selection in forward direction
“2” button...Main items Selection in reverse direction
“3” button...Sub items Selection in forward direction
“4” button...Sub items Selection in reverse direction
“VOL” button...Value of sub items change in forward direction ( + ), in reverse direction ( - )
27
TH-42PX77U / TH-42PE77U
10.1.2. Contents of adjustment mode
·
· Value is shown as a hexadecimal number.
· ·
·
· Preset value differs depending on models.
· ·
·
· After entering the adjustment mode, take note of the value in each item before starting adjustment.