Operating humidity range5 to 90% RH (no condensation)
n SYSTEM
SC-AK640 (E)Music center: SA-AK640 (E)
Speaker: SB-AK640 (EG)
Subwoofer: SB-W AK640 (EG)
SC-AK640 (EB)Music center: SA-AK640 (EB)
Speaker: SB-AK640 (EG)
Subwoofer: SB-W AK640 (EG)
SC-AK640 (EG)Music center: SA-AK640 (EG)
Speaker: SB-AK640 (EG)
Subwoofer: SB-W AK640 (EG)
For information on speaker system, please refer to the original
Service Manual (Order No. MD0601006C2) for SB-AK640EG and
(Order No. MD0601007C2) for SB-WAK640EG.
Notes:
1. Specifications are subject to change without notice. Mass and
dimensions are approximate.
2. Total harmonic distortion is measured by the digital spectrum
analyzer.
CONTENTS
Page Page
1 Safety Precautions
1.1. General Guidelines
1.2. Caution for AC Mains Lead
1.3. Before repair and adjustment
1.4. Protection Circuitry
2 Prevention of Electro Static Discharge (ESD) to
Electrostatically Sensitive (ES) Devices
3 Handling Precautions For Traverse Deck
4 Precaution of Laser Diode
5 Handling the Lead-free Solder
5.1. About lead free solder (PbF)
6 New Features
6.1. CRS1 Mechanism Overview
6.2. Music Port
7 Accessories
8 Operating Instructions Procedures
9 Self diagnosis and special mode setting
9.1. Special Mode Table
9.2. Error code Table
10 Assembling and Disassembling
10.1. Caution
10.2. Disassembly flow chart
10.3. Main Parts Location
10.4. Disassembly of Top Cabinet
4
4
5
5
6
6
7
8
9
9
10
10
12
13
14
16
16
18
22
22
23
24
25
10.5. Disassembly of Rear Panel
10.6. Disassembly of CD Changer Unit (CRS1)
10.7. Disassembly of Main P.C.B.
10.8. Disassembly of Transformer P.C.B.
10.9. Disassembly of Power P.C.B.
10.10. Disassembly of Front Panel Unit
10.11. Disassembly for Panel P.C.B.
10.12. Disassembly of Deck mechanism unit
10.13. Disassembly of Deck P.C.B.
10.14. Disassembly of Traverse Unit
10.15. Disassembly of optical pickup unit (CD mechanism )
10.16. Disassembly of Deck Mechanism
10.17. Replacement for cassette lid
10.18. Rectification for tape jam problem
11 Service Fixture and Tools
12 Service Positions
12.1. Checking and Repairing of Main P.C.B.
12.2. Checking and Repairing of Transformer P.C.B.
12.3. Checking and Repairing of Panel, Deck & Deck
20.1. IC7001 (MN6627954MA) Servo Processor,Digital Signal
Processor/Digital filter and D/A Converter
20.2. IC7002 (BA5948FPE2) IC 4CH Drive
20.3. IC2801 (C2CBYY000066) System Microprocessor
21 Exploded Views
21.1. Cabinet Parts Location
21.2. Deck Mechanism Parts Location (RAA4502-S)
21.3. Packaging
22 Replacement Parts List
79
80
81
82
83
85
86
86
87
87
89
91
93
95
97
3
SA-AK640E / SA-AK640EB / SA-AK640EG
1 Safety Precautions
1.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, ensure that all the protective devices such as insulation barriers and insulation papers shields are properly
installed.
3. After servicing, check for leakage current checks to prevent from being exposed to shock hazards.
1.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Using an ohmmeter measure the resistance value, between the jumpered AC plug and each expose d metallic cabine t part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1MΩ and 5.2MΩ .
When the exposed metal does not have a return path to the chassis, the reading must be
.
Fig. 1
1.1.2. Leakage Current Hot Check (See Figure 1)
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5kΩ, 10 watts resistor, in parallel with a 0.15µF capacitor, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may
be used to make the hot checks, leakage current must not exceed 1/2 milliamp. Should the measurement is out of the limits
specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to
the customer.
4
1.2. Caution for AC Mains Lead
SA-AK640E / SA-AK640EB / SA-AK640EG
1.3. Before repair and adjustment
Disconnect AC power, discharge Power Capacitors C5101, C5104, C5171, C5172, C5920, C5940 and C5950 through a 10Ω,5W
5
SA-AK640E / SA-AK640EB / SA-AK640EG
resistor to ground.
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
Current consum ption at AC 240V, 50 Hz in NO SIGNAL mode (volume min at CD mode) should be ~ 350mA.
1.4. Protection Circuitry
The protection circuitry may have operated if either of the following conditions are noticed:
·No sound is heard when the power is turned on.
·Sound stops during a performance.
The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are
“shorted”, or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used.
If this occurs, follow the procedure outlines below:
1. Turn off the power.
2. Determine the cause of the problem and correct it.
3. Turn on the power once again after one minute.
Note :
When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again.
2 Prevention of Electro Static Discharge (ESD) to
Electrostatically Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by electricity. Such components commonly are called
Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor “chip” components. The following techniques should be used to help reduce the incidence of component damage
caused by electro static discharge (ESD).
1. Immediately before handlin g any semiconductor component or semiconductor-equiped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potent ial shock reasons prior to applying power to the unit under test.
2. After removing an electrical assembly equiped with ES devices, place the assembly on a conductive surface such as aluminium
foil, to prevent electrostatic charge build up or exposu re of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4. Use only an anti-static solder remover device. Some solder removal devices not classified as “anti-static (ESD protected)” can
generate electrical charge to damage ES devices.
5. Do not use freon-propelled chemicals. These can generate electrical charges sufficie nt to damage ES devices.
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminium foil or
comparable conductive material).
7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installe d.
Caution
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
8. Minimize body motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the brushing
together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD) sufficient to
damage an ES device).
6
SA-AK640E / SA-AK640EB / SA-AK640EG
3 Handling Precautions For Traverse Deck
The laser diode in the traverse deck (optical pickup) may break down due to potential difference caused by the static electricity of
clothes or our human body.
So, be careful of electrostatic breakdown during repair of the traverse deck (optical pickup).
·Way of handling the traverse deck (optical pickup)
1. Do not subject the traverse deck (optical pickup) to static electricity as it is extremely sensitive to electrical shock.
2. To prevent the breakdown of the laser diode, an antistatic shorting pin is inserted into the flexible board (FFC board).
3. Do not to apply excessive stress to the flexible board (FFC board). When removing or connecting the short pin, finish the job
in as short time as possible.
4. Do not turn the variable resistor for laser power adjustment. (It is pre-adjusted during production time)
Grounding for electrostatic breakdown prevention
1. Human body grounding
Use the anti-static wrist strap to discharge the static electricity from your body.
2. Work table grounding
Put a conductive material (sheet) or steel sheet on the area where the traverse deck (optical pickup) is place, and ground the
sheet.
Caution :
The static electricity of your clothes will not be grounded through the wrist strap. So, take care not to let your clothes touch the
traverse deck (optical pickup).
Caution when replacing the Traverse Deck
The traverse deck has a short point shorted with solder to protect the laser diode against electrostatics breakdown. Be sure to
remove the solder from the short point before making connections.
7
SA-AK640E / SA-AK640EB / SA-AK640EG
4 Precaution of Laser Diode
Caution :
This product utilizes a laser diode with the unit turned "ON", invisible laser radiation is emitted from the pick up lens.
Wavelength : 780 nm
Maximum output radiation power from pick up : 100 µW/VDE
Laser radiation from pick up unit is safety level, but be sure the followings:
1. Do not disassemble the optical pick up unit, since radiation from exposed laser diode is dangerous.
2. Do not adjust the variable resistor on the pick up unit. It was already adjusted.
3. Do not look at the focus lens using optical instruments.
4. Recommend not to look at pick up lens for a long time.
ACHTUNG :
Dieses Produkt enthält eine Laserdiode. Im eingeschalteten Zustand wird unsichtbare Laserstrahlung von der Lasereinheit
abgestrahlt.
Wellenlänge : 780nm
Maximale Strahlungsleistung der Lasereinheit :100 µW/VDE
Die Strahlung an der Lasereinheit ist ungefä hrlich, wenn folgende Punkte beachtet werden:
1. Die Lasereinheit nicht zerlegen, da die Strahlung an der freigelegten Laserdiode gefährlich ist.
2. Den werkseitig justierten Einstellregler der Lasereinhit nicht verstellen.
3. Nicht mit optischen Instrumenten in die Fokussierlinse blicken.
4. Nicht über längere Zeit in die Fokussierlinse blicken.
ADVARSEL: I dette a apparat anvendes laser.
CAUTION!
THIS PRODUCT UTILIZES A LASER.
USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY RESULT
IN HAZARDOUS RADIATION EXPOSURE.
n Use of caution label
8
SA-AK640E / SA-AK640EB / SA-AK640EG
5 Handling the Lead-free Solder
5.1. About lead free solder (PbF)
Distinction of PbF P.C.B.:
P.C.B.s (manufactured) using lead free solder will have a PbF stamp on the P.C.B.
Caution:
· Pb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher. Please
use a high temperature soldering iron. In case of soldering iron with temperature control, please set it to 700 ± 20°F (370 ±
10°C).
·Pb free solder will tend to splash when heated too high (about 1100°F/600°C).
·W hen soldering or unsoldering, please completely remove all of the solder on the pins or solder area, and be sure to heat the
soldering points with the Pb free solder until it melts enough.
9
SA-AK640E / SA-AK640EB / SA-AK640EG
6 New Features
6.1. CRS1 Mechanism Overview
6.1.1. General Feature
· This is a five disc changer mechanism for CD/DVD. The outline figure is shown below.
10
SA-AK640E / SA-AK640EB / SA-AK640EG
· The mechanism has "CHANGE WHILE PLAY" function. It open other trays for disc exchanging while one tray is at PLAY
position performing recording or reproducing.
· The mechanism can quickly change all trays with "CHANGE ALL" function. All trays can be move to OPEN position with one
operation.
· There is no sensor to indicate presence of disc on any tray.
6.1.2. Hardware composition
·Below is the hardware components of the mechanism
NameFunction
Open Switch (OPEN-SW)The switch is used to detect normal tray opening
The switch is used for detect tray being manually push/trigger when full open
Home Switch (HOME-SW)Is used to detect cam gear home position
Close Sensor (CLOSE-SENSOR)Used for normal single tray closing
Used to detect cam gear rotate to Play Driving position
Play Switch (PLAY-SW)Detect TRV clamping complete position
Stocking Switch (STOCK-SW)Detect tray completely transfer for play position to stocking position
UD Sensor (UD-SENSOR)Detect TRV vertical movement position
Top Switch (TOP-SW)Detect a default position of TRV vertical movement position
Driver ICTo drive Motor
MotorMain driving source for changer
PlungerSwitching the driving source from motor to:
1. Tray open/close
2. Drive tray to play/stock position and TRV vertical movement
6.1.3. Mechanism Operation
· This mechanism has the following state:
1. Driving of a tray to open/close
2. Up/down operation of a traverse performs a state changes of tray.
By using the plunger to lift/release of a switching gear, and the cam gear to lift/release the function gear the motor can be link
to several gear trains to perform various operations.
· The functions that can be perform in this mechanism are described as below:
ConditionExplanation
Open current playing trayThe state to change current playing disc. All tray will be open at once and current tray at PLAY position
Open AllThe state where all trays being driven to OPEN position. The disc can be taken in or out from tray to tray
StockThe state where the trays are stored in STOCK position
PlayThe state where one of the tray 5 trays is being driven to PLAY position and clamped by traverse unit
Play & Open Tray-*The state where one of the tray is in playing position performing recording or reproducing, other trays can
ChangeThe state when one of the opened tray being driven from OPEN position to STOCK position and other
Close AllThe state where all open trays will being driven from OPEN position to STOCK position, one by one from
will be expose.
by close tray one by one from top to bottom.
be used (OPEN position) for disc exchanging without stopping the recording or reproducing process.
opened trays remain still at OPEN position.
top to bottom
11
SA-AK640E / SA-AK640EB / SA-AK640EG
Note: * represent tray number (from 1 ~ 5)
6.1.4. New CD Mechanism (CRS1)
Note:
This service manual does not contain the following information for the mention CD Mechanism drive:
·Schematic Diagram, Block Diagram and P.C.B. layout of CD Loading P.C.B.
·Part List for individual parts of the mechanism.
·Explode d View and Parts List for individual parts of the CD Mechanism drive.
Please refer to the original service manual (Order No. MD0509368C0) for the CD Mechanism Drive CRS1.
6.2. Music Port
With reference to page 16 of the operating instruction manual.
12
7 Accessories
SA-AK640E / SA-AK640EB / SA-AK640EG
Remote Control
FM Antenna Wire
AC Cord (For E/EG
only)
AC Cord (For EB
only)
AM Loop Antenna
Antenna
Adaptor
(For EB
only)
13
SA-AK640E / SA-AK640EB / SA-AK640EG
8 Operating Instructions Procedures
14
SA-AK640E / SA-AK640EB / SA-AK640EG
15
SA-AK640E / SA-AK640EB / SA-AK640EG
9 Self diagnosis and special mode setting
This unit is equipped with functions for checking and inspecting namely: Self-Diagnostic and Test Mode.
9.1. Special Mode Table
ItemFL DisplayKey Operation
Mode NameDescriptionFront Key
Self -Diagnostic
Mode
CD Test Mode To enter into checking the
CD Auto
Adjustment
Toenterintoself
diagnostic checking for
main unit.
reliability of changer unit.
To check the CD auto
adjustmentresultfor
FLOCK,TLOCKand
CLVS.
1. Select [
] for TAPE mode (Ensure no tape is
inserted).
2. Press and hold [
seconds follow by [
To exit, press
main unit or remote control.
1. Select [] for CD mode.
2. Press and hold [
seconds follow by [
To exit, press
main unit or remote control.
In CD Test Mode:
1. Press [0] button on the remote control.
To exit, press
main unit or remote control.
]button for 3
].
button on
] button for 3
].
button on
button on
CD Changer
Reliability Test
(CRS1)
Doctor ModeTo enter into Doctor
Cold StartTo activate cold start
Changer
Reliability Test
Todeterminethe
reliability of CD Changer
Unit.
(For more information,
refer to section 9.1.1)
Mode for checking of
various items and
displaying EEPROM and
firmware version.
upon next AC power up.
To check the function
operation of changer unit.
(For more information,
refer to 9.1.1)
1.
2.
1. All segments will light up for 1 second.
2. The Check Sum of EEPROM and firmware
version will be display.
* ROM correction
** Firmware version No:
In Self-Diagnostic Mode:
1. Select [
2. Press [
To exit, press
main unit or remote control.
(The tray will return to PLAY position and then
power off)
In any mode:
1. Press [
follow by [4] and [7] on remote control.
To exit, press [ENTER] button on remote
control or
unit or remote control.
In doctor mode:
1. Press [4] button on remote control.
To exit, press [ENTER] button on remote
control or
unit or remote control.
In doctor mode:
1. Press [DISC] on remote control.
To exit, press [ENTER] button on remote
control or
unit or remote control.
] for CD mode.
] button.
button on
] button on main unit
button on main
button on main
button on main
16
ItemFL DisplayKey Operation
Mode NameDescriptionFront Key
FL Display Test TochecktheFL
segmentsdisplay (All
segments will light up and
LED will blink at 0.5
second interval)
Tape Eject Test To check on the tape
eject function (For deck
1/2)
In doctor mode:
1. Press [DIMMER] button on remote control.
In doctor mode:
1. Press [PROGRAM] button on remote
9.1.1. CD changer unit ageing test mode
Below is the process flow chart of ageing for the CD changer unit. (CRS1)
SA-AK640E / SA-AK640EB / SA-AK640EG
control.
17
SA-AK640E / SA-AK640EB / SA-AK640EG
9.2. Error code Table
Self-Diagnosis Function (refer Section 9.1) provides information on any problems occuring for the unit and its respective
components by display ing the error codes. These error code such as U**, H** and F** are stored in memory and held unless it is
cleared.
18
The error code is automatically display after entering into self-diagnostic mode.
Error CodeDiagnosis Contents Description of errorAutomatic FL DisplayRemarks
H01Mode SW, plunger
and capstan motor
abnormal
For deck mechanism unit (For deck 1/2).
Press [
next error.
SA-AK640E / SA-AK640EB / SA-AK640EG
] on main unit for
H02Rec INH SW
abnormal
For deck mechanism unit (For deck 2).
Press [
] on main unit for
next error.
H03HALF SW abnormalFor deck mechanism unit (For deck 1/2).
Press [
] on main unit for
next error.
F01
Reel pulse abnormal
For deck mechanism unit (For deck 1/2).
Press [
] on main unit for
next error.
F02
F15RESET SW
F26Transmission error
TPS error
abnormal
between CD Servo
LSI IC and
microprocessor IC
REST SW: ON is not
detectedwithinthe
specified time.
When set to CD mode,
the sense signal does
not turn “Low”, a fail safe
timeaftersystem
For CD unit (For Traverse).
Press [
] on main unit for
next error.
For CD unit (For Traverse).
Press [
] on main unit for
next error.
command transmission
is sent.
F61Power Amp IC output
abnormal
Uponpoweron,
PCONT=HIGH,
DCDET=L after checking
For power.
Press [
next error.
] on main unit for
LSI.
IHMSCam gear
abnormality
Cam gear does not
rotateto“HOME”
position.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
ICSLCam gear/gear units
abnormal
ISTKDrive rack/gear
assembly abnormal
IPLYDrive rack/gear
assembly abnormal
Cam gear does not
rotate to “PLAY” driving
position and hence does
not drive playing tray to
“STOCK” position.
The tray drive rack does
not move to “STOCK”
position. (Tray does not
moveto“STOCK”
position)
The tray drive rack does
not move to “PLAY”
position. (Tray does not
move to “PLAY” position)
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
19
SA-AK640E / SA-AK640EB / SA-AK640EG
Error CodeDiagnosis Contents Description of errorAutomatic FL DisplayRemarks
ITOPUD assemblyUD Rack does not move
to front direction. This
lead to UD base not
raise to top position.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
IUDSUD assemblyAfterTOPSWis
detected, UD rack does
not move into tray 1
position.
HOMECam gear/gear
assembly abnormal
Cam gear does not
moveto“HOME”
position under following
conditions
1. After tray is load to
“PLAY” position.
2. After tray is unload
to “STOCK” position.
LOADTray drive assembly
abnormal
Tray unit does not move
from “STOCK” to “PLAY”
position
PDRVCam gear/gear
assembly abnormal
Cam gear does not
move from “HOME” to
“PLAY” drive position.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
UDUUD base asssembly
abnormal
UDDUD base asssembly
abnormal
UD1UD base asssembly
abnormal
F1NGFail - safe mode. (For
open/close tray
unit(s))
F2NGFail - safe mode. (For
open/close tray
unit(s))
UD Base assembly does
not move upwards from
tray 5 to tray 2
UD Base assembly does
not move downwards
from tray 1 to tray 5.
UD Base assembly does
not move to tray 1.
When the tray open
operation is performed, it
fails to open. It will
automatically close all
trays after the time-out
by the microprocessor.
During this time when it
fails, the error code will
appear.
When the tray close
operation is performed, it
fails to close. It will
automatically open all
trays after the time-out
by the microprocessor.
During this time when it
fails, the error code will
appear.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
20
SA-AK640E / SA-AK640EB / SA-AK640EG
Error CodeDiagnosis Contents Description of errorAutomatic FL DisplayRemarks
SRVC_TRVTo unlock the
traverse unit for
service
RSETCam gear jam/close
sensor faulty
1. Alltrayssetto
“STOCK” position
2. Mechanism set to
tray 5
3. Cam gear set to
“HOME” position
During tray re-open, the
cam gear will rotate in
the opposite direction to
resetthecam
gearposition. When it
fails, the error code will
appear.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit.
For CD changer unit (CRS1).
Press [SINGLE CHANGE] on main unit
for next error.
CRS1 Error Code display
1. The errors that occured in CRS1 Mechanism can be recalled and displayed, in the order of the occurence under self-diagnostic
(Refer to Section 9.1 for procedures to enter this mode.
· Only the first 5 errors will be memorized (in backup memory). The subsequence error shall be ignored and not memorize.
For system with EEPROM as memory backup,memory space in EEPROM is neccesary.
2. To display all error code memorized
In CRS1 Self-Diagnostic mode, press [SINGLE CHANGE] to display subsequence error code.
It shall repeat after reaching error no. 5.
e.g.:
[1____IHMS]→ [SINGLE CHANGE]
[2____ITOP]→ [SINGLE CHANGE]
[3____HOME]→ [SINGLE CHANGE]
[4____LOAD]→ [SINGLE CHANGE]
[5_____UDD]→ [SINGLE CHANGE]
3. To clear the error code memory
In CRS1 Self-Diagnostic mode, long press [SINGLE CHANGE] key (2s or more)
21
SA-AK640E / SA-AK640EB / SA-AK640EG
10 Assembling and Disassembling
10.1. Caution
Special Note:
This model uses a new CD changer unit CRS1. In this following section does not contain the necessary disassembly &
assembly information for the CD changer unit (CRS1) except the disasembly & assembly of traverse unit. Kindly refer to the
original service manua l for the CD changer unit. (Order No. MD0509368C0).
“ATTENTION SERVICER”
Some chassis components may have sharp edges. Be careful when disassembling and servicing.
1. This section describes procedures for checking the operation of the major printed circuit boards and replacing the main
components.
2. For reassembly after operation checks or replacement, reverse the respective procedures.
Special reassembly procedures are described only when required.
3. Select items from the following index when checks or replacement are required.
4. Refer to the Parts No. on the page of “Parts Location and Replacement Parts List” (Section 22), if necessary.
Warning :-
This product uses a laser diode. Refer to caution statement Precaution of Laser Diode.
Caution:
After replacing of CD Changer Unit, ageing test is necessary. Please confirm operation for CD Changer Unit.
Below is the list of disassembly sections
·Disasse mbly of Top Cabinet
·Disasse mbly of Rear Panel
·Disasse mbly of CD Changer Unit
·Disasse mbly of Main P.C.B.
·Disasse mbly of Transformer P.C.B.
·Disasse mbly of Power P.C.B.
·Disasse mbly of Front Panel Unit
·Disasse mbly of Panel P.C.B.
·Disasse mbly of Deck Mechanism Unit
·Disasse mbly for Deck P.C.B.
·Disasse mbly of Traverse Unit
·Disasse mbly of Optical Pickup Unit (CD Mechanism)
·Disasse mbly of Deck Mechanism
·Replacement for casse tte lid
·Rectification for tape jam problem
22
SA-AK640E / SA-AK640EB / SA-AK640EG
10.2. Disassembly flow chart
The following chart is the procedure for disassembling the casing and inside parts for internal inspection when carrying out the
servicing.
To assemble the unit, reverse the steps shown in the chart as below.
23
SA-AK640E / SA-AK640EB / SA-AK640EG
10.3. Main Parts Location
24
10.4. Disassembly of Top Cabinet
Step 1 Remove 3 screws at each side and 5 screws at rear
panel.
Step 2 Lift up both sides of the top cabinet, push the top
cabinet towards the rear to remove the top cabinet.
SA-AK640E / SA-AK640EB / SA-AK640EG
10.5. Disassembly of Rear Panel
·Follow the (Step 1) - (Step 2) of Item 10.4 - Disassembly of Top Cabinet
Step 1 Remove 6 screws.
Step 2 Disconnect cable CN2810 (Fan) at Main P.C.B..
Step 3 Remove rear panel.
10.6. Disassembly of CD Changer Unit (CRS1)
·Follow the (Step 1) - (Step 2) of Item 10.4 - Disassembly of Top Cabinet
Step 1 Remove 1 screw at rear panel.
25
SA-AK640E / SA-AK640EB / SA-AK640EG
Step 2 Detach the FFC cables (CN2801 & CN2805).
Step 4 Lift the CD changer unit upwards to remove it.
· Disasse mbly of Mecha Chassis
Step 3 Release the claws on both ends.
Step 5 Remove 2 screws.
Step 6 Remove the Mecha Chassis.
Note:
For disassembly & assembly of traverse unit, please refer to
section 10.14 of this service manual.Please refer to original
Service Manual for the Disassembly and Assembly of the CD
Changer Unit (CRS1).
26
10.7. Disassembly of Main P.C.B.
·Follow the (Step 1) - (Step 2) of Item 10.4 - Disassembly of Top Cabinet
·Follow the (Step 1) - (Step 4) of Item 10.6 - Disassembly of CD Changer Unit
·Follow the (Step 1) - (Step 3) of Item 10.5 - Disassembly of Rear Panel
Step 1 Disconnect FFC cables (CN2803, CN280 6 and
CN2951).
Step 2 Detach connectors (CN2808 & CN2809).
Step 3 Remove Main P.C.B..
SA-AK640E / SA-AK640EB / SA-AK640EG
10.8. Disassembly of Transformer P.C.B.
·Follow the (Step 1) - (Step 2) of Item 10.4 - Disassembly of Top Cabinet
·Follow the (Step 1) - (Step 3) of Item 10.5 - Disassembly of Rear Panel
·Follow the (Step 1) - (Step 4) of Item 10.6 - Disassembly of CD Changer Unit
Step 1 Disconnect connectors (CN5950 & CN595 1).
Step 2 Remove 3 screws (Mounting screws for transformer to
bottom chassis).
Step 3 Push the Transformer P.C.B. sidewards to remove it.
27
SA-AK640E / SA-AK640EB / SA-AK640EG
10.9. Disassembly of Power P.C.B.
·Follow the (Step 1) - (Step 2) of Item 10.4 - Disassembly of Top Cabinet
·Follow the (Step 1) - (Step 4) of Item 10.6 - Disassembly of CD Changer Unit
·Follow the (Step 1) - (Step 3) of Item 10.5 - Disassembly of Rear Panel
·Follow the (Step 1) - (Step 3) of Item 10.7 - Disassembly of Main P.C.B.
Step 1 Remove the 5 screws on Power P.C.B..
Step 2 Detach cable (CN5950) remove the 5 screws on Power
P.C.B..
Step 3 Remove Power P.C.B..
Note:
Insulate the Power P.C.B. with insulation material to avoid short
circuit.
· Replacement of the Power Amp IC or Voltage Regulator
Step 4 Remove 2 screws at the Power Amp IC and/or 3
screws to Voltage Regulator.
Step 5 Cut the joints with a metal cutter as shown below.
Step 6 Desolder the terminals to replace the components.
Step 7 Fix back the cut portion with a screw as shown.
28
10.10. Disassembly of Front Panel Unit
·Follow the (Step 1) - (Step 2) of Item 10.4 - Disassembly of Top Cabinet
·Follow the (Step 1) - (Step 4) of Item 10.6 - Disassembly of CD Changer Unit
Step 2 Bent the front panel unit slightly forward as arrow
shown.
Step 4 Remove the front panel unit.
Note: Ensure 2 claws located at the bottom chassis is seated
into the 2 slots at bottom of front panel at 2 catches (one on
each side) of bottom chassis to be aligned to front panel’s slot.
Assembly is secured upon hearing clicking sound.
29
SA-AK640E / SA-AK640EB / SA-AK640EG
10.11. Disassembly for Panel P.C.B.
·Follow the (Step 1) - (Step 2) of Item 10.4 - Disassembly of Top Cabinet
·Follow the (Step 1) - (Step 4) of Item 10.6 - Disassembly of CD Changer Unit
·Follow the (Step 1) - (Step 4) of Item 10.10 - Disassembly of Front Panel Unit
Step 1 Remove the volume knob.
Step 2 Remove Lid.
Note: Do not misplace the spring.
Step 2 Remove 12 screws.
Step 3 Release 2 catches.
Step 4 Remove Panel P.C.B..
10.11.1. Disassembly of Lid
Step 1 Lift the spring sideward.
30
Loading...
+ 78 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.