Panasonic MLR-351H User Manual

MLR-351H
Plant Growth Chamber
Features:
• Accurately reproduces and controls a wide variety of temperatures, humidity and lighting patterns.
Panasonic… the new name for SANYO
www.panasonic.com/biomedical
Plant Growth Chamber
The model MLR series humidified plant growth chamber has a temperature range of 0°C to 50°C, with programmable lighting for diurnal protocols in plant and insect cell culture applications.
Versatile Environmental Test Chamber
• Graphic LCD provides easier operation
• Programmable temperature, lighting and humidity function
• Microprocessor P.I.D. temperature control
• Data logging function
• Easy calibration through controller
• Small lightweight, high molecular membrane-type humidity sensor
Technology
The wide variety of temperatures, humid­ity and lighting patterns that are essential in research and environmental studies can now be accurately reproduced and controlled.
Dimensions
Model Number
MLR-351H - PA
Volume
(cu.ft. per chamber)
10.4 cu.ft
294 L
Microprocessor P.I.D. Control
Allows accurate, reproducible and flexible programming of all performance parameters with optimal energy management; comprehensive security monitoring and alarm functions are standard. The temperature and humid­ity inside the incubator can be set and monitored easily by means of precise microprocessor temperature control with an LCD graphic display.
The temperature fluctuations allows precise experiments plus energy.
Exterior Dimensions
(w x f-b x h)
29.9” x 27.6” x 72.2”
760 x 700 x 1835 mm
Programmable
Nine user programmable steps allow simulation of environmental conditions; 15 variable intensity fluorescent lamps create uniform lighting.
Gentle Air Circulation
Maximizes temperature uniformity at all shelf levels.
Ergonomic Design
Slim-profile cabinet offers sophisticated performance in minimal space.
Alpha-Numeric Controller
The new LCD controller improves user interface for better programming and control.
Interior Dimensions
(w x f-b x h)
20.5” x 19.3” x 4 4.7”
520 x 49 0 x 1135 mm
Plant Growth Chamber
Environmental Performance
Temperature Range
Temperature Distribution ±1.0°C (lamp OFF ) ±2.5°C (lamp ON )
Temperature Accuracy
Humidity Range 55-86% & 60 -90% RH
5°C to 50 °C (lamp OFF ) 10°C to 50°C ( lamp ON )
±0.3°C
Temperature Distribution (°C)
Point
The temperature distribution (°C) is determined using ½H and centre point (5) as the zero reference.
Environmental Controls
Temperature Programmable Operation
Temperature Control
Refrigerant R404A
Heater 340W
Humidit y Control System Ultrasonic P.I.D. Control
Defrosting System
Evaporator Fin and tube type, forced circulation
Air Circulation Forced air circulation
Compressor Fully hermetic, 325W output
12 steps (10 patterns), 98 cycle or limitless;
Clock mode: 00:0 0 to 23:59, Timer mode
P.I.D. microprocessor control and refrigera -
Automatic defrost (3 patters), manual
Panasonic Healthcare Company of North America
1300 Michael Drive, Suite A, Wood Dale, IL 60191 Toll Free USA (800) 858-8442, Fax (630) 238-0074 www.panasonic.com/biomedical
© Panasonic Printed in USA 2012.02 JB JB201202V1
00:01 to 9 9:59
tion capacity control
defrost
Loading...