Thank you for purchasing a Panasonic digital cordless phone.
Important:
L The suffix (NZ) in the following model numbers will be omitted in these
instructions: KX-TG1311NZ/KX-TG1312NZ/KX-TG1313NZ
Model composition
KX-TG1311 series
L Model shown is
KX-TG1313.
Model No.
KX-TG1311KX-TG1311KX-TGA1311
KX-TG1312KX-TG1311KX-TGA1312
KX-TG1313KX-TG1311KX-TGA1313
Base unitHandset
Part No.Part No.Quantity
Quantity
No. Accessory item/Part number
1AC adaptor for base unit/
PQLV207AL
2Telephone line cord111
3Rechargeable batteries
4Handset cover
5Charger—12
6AC adaptor for charger/
PQLV209AL
*1 See page 2 for replacement battery information.
*2 The handset cover comes attached to the handset.
123456
Replacement battery information:
L Replace batteries only with a nickel metal hydride (Ni-MH) type of
battery. This model requires 2 AAA (R03) batteries for every handset.
For best performance, we recommend using Panasonic rechargeable
batteries (Model No. HHR-4MPT).
L Replacement batteries may have a different capacity from that of the
supplied batteries.
*2
*1
KXTG1311
KXTG1312
111
246
123
—1 2
KXTG1313
2
Important information
General
L Use only the AC adaptor supplied with this product, noted on page 2.
L Do not connect the AC adaptor to any AC outlet other than a standard
220–240 V AC outlet.
L This product is unable to make calls when:
− the portable handset battery(ies) need recharging or have failed.
− there is a power failure.
− the key lock feature is turned on.
− the call bar feature is turned on (only phone numbers stored in the unit
as emergency numbers can be called).
L Do not open the base unit, charger, or handset other than to replace the
battery(ies).
L Consult the manufacturer of any personal medical devices, such as
pacemakers or hearing aids, to determine if they are adequately
shielded from external RF (radio frequency) energy. (The product
operates in the frequency range of 1.88 GHz to 1.90 GHz, and the RF
transmission power is 250 mW (max.).) Do not use the product in health
care facilities if any regulations posted in the area instruct you not to do
so. Hospitals or health care facilities may be using equipment that could
be sensitive to external RF energy.
L Care should be taken that objects do not fall onto, and liquids are not
spilled into, the product. Do not subject this product to excessive smoke,
dust, mechanical vibration or shock.
L Only the supplied handset can be used with the base unit. No other
handsets can be registered or used.
Environment
L Do not use this product near water.
Introduction
L This product should be kept away from heat sources such as radiators,
cookers, etc. It should also not be placed in rooms where the
temperature is less than 5 °C or greater than 40 °C.
Warning:
L To prevent the risk of electrical shock, do not expose this product to rain
or any other type of moisture.
L Unplug this product from power outlets if it emits smoke, an abnormal
smell, or makes unusual noise. These conditions can cause fire or
electric shock. Confirm that smoke has stopped emitting and contact an
authorised service centre.
L Do not spill liquids (detergents, cleansers, etc.) onto the telephone line
cord plug, or allow it to become wet at all. This may cause a fire. If the
telephone line cord plug becomes wet, immediately pull it from the
telephone wall jack, and do not use.
L Do not place or use this product near automatically controlled devices
such as automatic doors and fire alarms. Radio waves emitted from this
product may cause such devices to malfunction resulting in an accident.
L Regularly remove any dust, etc. from the AC adaptor/power plug by
pulling it from the power outlet, then wiping with a dry cloth. Accumulated
dust may cause an insulation defect from moisture, etc. resulting in a fire.
L Do not damage the power cord/plug. This may cause a short circuit,
electric shock, and/or fire.
L Do not touch the plug with wet hands.
L The AC adaptor is used as the main disconnect device. Ensure that the
AC outlet is installed near the product and is easily accessible.
Battery caution
L We recommend using the battery(ies) noted on page 2. USE ONLY
rechargeable Ni-MH batteries AAA (R03) size.
L Do not mix old and new batteries.
L Do not dispose of the battery(ies) in a fire, as they may explode. Check
with local waste management codes for special disposal instructions.
3
Introduction
L Do not open or mutilate the battery(ies). Released electrolyte from the
battery(ies) is corrosive and may cause burns or injury to the eyes or
skin. The electrolyte may be toxic if swallowed.
L Exercise care when handling the battery(ies). Do not allow conductive
materials such as rings, bracelets or keys to touch the battery(ies),
otherwise a short circuit may cause the battery(ies) and/or the
conductive material to overheat and cause burns.
L Charge the battery(ies) provided with or identified for use with this
product only in accordance with the instructions and limitations specified
in this manual.
L Only use a compatible base unit (or charger) to charge the battery(ies).
Do not tamper with the base unit (or charger). Failure to follow these
instructions may cause the battery(ies) to swell or explode.
General notices
L This equipment will be inoperable when mains power fails.
L When a failure occurs which results in the internal parts becoming
accessible, disconnect the power supply cord immediately and return
this unit to an authorised service centre.
L Disconnect the telecom connection before disconnecting the power
connection prior to relocating the equipment, and reconnect the power
first.
L No “111” or other calls can be made from this device during a mains
power failure.
L This equipment shall not be set to make automatic calls to the Telecom
“111” Emergency Service.
L To minimise the possibility of lightning damage, when you know that a
thunderstorm is coming, we recommend that you:
− Unplug the telephone line cord from the phone socket.
− Unplug the AC adaptor from the AC power outlet.
L The earpiece on the handset is magnetised and may retain small
metallic objects.
L Not all telephones will respond to incoming ringing when connected to
the extension socket.
L This equipment may not provide for the effective hand-over of a call to
another device connected to the same line.
L The grant of a Telepermit for any item of terminal equipment indicates
only that Telecom has accepted that the item complies with minimum
conditions for connection to its network. It indicates no endorsement of
the product by Telecom, nor does it provide any sort of warranty. Above
all, it provides no assurance that any item will work correctly in all
respects with another item of Telepermitted equipment of a different
make or model, nor does it imply that any product is compatible with all
of Telecom’s network services.
Important notice:
L Under power failure conditions, this telephone may not operate. Please
ensure that a separate telephone, not dependent on local power, is
available for emergency use.
Notice for product disposal, transfer, or return
L This product can store your private/confidential information. To protect
your privacy/confidentiality, we recommend that you erase the
information such as phonebook or caller list entries from the memory
before you dispose of, transfer, or return the product.
4
Information on Disposal in other Countries outside the European
Union
Preparation
Preparation
Connections
Base unit
The base unit can be mounted on the wall, if required.
L Use only the supplied Panasonic AC adaptor PQLV207AL.
L Use only the supplied telephone line cord. Using another telephone line
cord may not allow the unit to work properly.
These symbols are only valid in the European Union. If you wish to discard
these items, please contact your local authorities or dealer and ask for the
correct method of disposal.
30 mm
Screws
(Not supplied)
Hooks
(220–240 V AC, 50/60 Hz)
To single-line
telephone socket
5
Preparation
Charger
Available for:
KX-TG1312/KX-TG1313
The charger can be mounted on the wall, if required.
L Use only the supplied Panasonic AC adaptor PQLV209AL.
Hooks
(220–240 V AC, 50/60 Hz)
Note:
L Never install telephone wiring during a lightning storm.
L Do not connect the AC adaptor to a ceiling-mounted AC outlet, as the
weight of the adaptor may cause it to become disconnected.
L The unit is not designed to be used with rotary/pulse dialling services.
During a power failure
The unit will not work during a power failure. We recommend connecting a
corded-type telephone (without AC adaptor) to the same telephone line or
to the same telephone line socket using a BT double adaptor.
25.2 mm
Screws
(Not supplied)
If you subscribe to a DSL/ADSL service
Please attach a DSL/ADSL filter (contact your DSL/ADSL provider) to the
telephone line between the base unit and the telephone line socket in the
event of the following:
− noise is heard during conversations.
− Caller ID features do not function properly.
Telephone line cord
To single-line
telephone socket
DSL/ADSL filter
Location
For maximum distance and noise-free operation, place your base unit:
− away from electrical appliances such as TVs, radios, personal
computers, or other phones.
− in a convenient, high, and central location.
6
Preparation
Battery installation
Important:
L Use the supplied rechargeable batteries (Part No. HHR-55AAAB).
L When installing the batteries:
− Wipe the battery ends (S, T) with a dry cloth.
− Avoid touching the battery ends (S, T) or the unit contacts.
− Confirm correct polarities (S, T).
L If the handset does not automatically turn on after installing batteries,
press {ih} for about 1 second, or place the handset on the base unit
or charger.
Insert the batteries negative (T) end first. Close the handset cover.
Turning the power on/off
Power on
Press {ih} for about 1 second.
Power off
Press {ih} for about 2 seconds.
Battery charge
Place the handset on the base unit or charger for about 7 hours before
initial use.