4Specifications----------------------------------------------------115Location of ControlsandComponents------------------136Service Mode-----------------------------------------------------16
1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment
which are important for safety. These parts are marked by
in the Schematic Diagrams, Circuit Board Layout,Exploded Views andReplacement Parts List. It is essen-tial that these critical parts should be replaced with manu-facturer’s specifiedparts to prevent X-RADIATION,shock, fire, or other hazards. Do not modify the originaldesign without permission of manufacturer.
2.An IsolationTransformer should always be used duringthe servicing of AC Adaptor whose chassis is not isolatedfrom the AC power line. Use a transformer of adequatepower rating as this protects the technician from acci-dents resulting in personalinjury from electricalshocks. Itwill also protect AC Adaptor from being damaged byacci-dental shorting that may occur during servicing.
3.When servicing, observethe original lead dress. If a shortcircuit is found, replace allparts which havebeen over-heated or damaged by the short circuit.
4.After servicing, see to it that all the protective devicessuch as insulation barriers, insulation papers shields areproperly installed.
5.After servicing, make the following leakage currentchecks to prevent the customer from being exposed toshock hazards.
1.3.Leakage Current Hot Check
(See Figure. 1)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2.Connect a 1.5 k, 10 W resistor, in parallel with a 0.15Fcapacitor,between each exposed metallic part on thesetanda good earth ground, as shown in Figure. 1.
3.Use an AC voltmeter, with 1 k/V or more sensitivity, tomeasure the potential across theresistor.
4.Check each exposed metallic part, and measure the volt-ageat each point.
5.Reverse the AC plug in the AC outlet and repeat each ofthe abovemeasurements.
6.The potential at any point should not exceed 0.75 V RMS.A leakage current tester(Simpson Model 229 or equiva-lent) may be used to make the hot checks, leakage cur-rent must not exceed 1/2 mA. In case a measurement isoutside of the limits specified,there is a possibility of ashock hazard, and the equipment should be repaired andrechecked before it is returnedto the customer.
1.2.Leakage Current Cold Check
1.Unplug the AC cord and connect a jumper between thetwo prongs on the plug.
2.Measure the resistance value, with an ohmmeter,between the jumpered AC plug and each exposed metal-lic cabinet part on theequipment such as screwheads,connectors, controlshafts, etc. When the exposed metal-lic part has areturn path to the chassis, the readingshould be between 1 Mand 5.2 M. When the exposedmetal does not have a return pathto the chassis, thereading must be infinity.
Figure. 1
3
2Warning
2.1.Prevention of Electrostatic Discharge (ESD) to Electrostatically
Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor "chip"components. The following techniques should be used tohelp reducethe incidence of component damagecaused by electrostatic discharge(ESD).
1.Immediately before handling any semiconductor component orsemiconductor-equippedassembly, drain off any ESDon yourbody bytouching a known earth ground. Alternatively,obtainand wear a commercially available discharging ESD wrist strap,which should be removedfor potential shock reasons prior to applying power to the unit under test.
2.After removingan electricalassembly equipped with ES devices, place the assemblyon a conductive surface such as alumi-num foil, to prevent electrostatic charge buildup or exposure of the assembly.
3.Useonly a grounded-tip solderingiron tosolder or unsolder ES devices.
4.Use only an antistatic solder removal device.Some solder removal devicesnot classifiedas “antistatic (ESD protected)” cangenerate electrical chargesufficient to damage ES devices.
5.Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
6.Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Mostreplacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or compara-ble conductivematerial).
7.Immediately before removing the protective material fromtheleads of a replacement ES device, touch the protective materialto the chassis or circuit assembly into which the device will beinstalled.
CAUTION :
Besurenopower is appliedto the chassis or circuit, and observe all other safety precautions.
8.Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as thebrushing together of your clothes fabric or the lifting of yourfoot from a carpeted floor can generate static electricity (ESD) suf-ficient to damage an ES device).
2.2.How to Recycle the Lithium Ion Battery (U.S. Only)
4
2.3.Caution for AC Cord
(For EB/GC)
2.3.1.Information for Your Safety
IMPORTANT
Your attention is drawn to the fact that recording of prerecorded tapes or discs orother published or broadcastmaterial may infringe copyright laws.
WARNING
Toreduce the risk of fire or shock hazard, do not exposethis equipment to rain or moisture.
CAUTION
To reducethe risk of fireor shock hazardand annoyinginterference, use the recommended accessories only.
FOR YOURSAFETY
DO NOT REMOVE THE OUTER COVER
To prevent electric shock, donot remove the cover. No userserviceable parts inside. Refer servicing to qualified service
personnel.
2.3.2.Caution for AC Mains Lead
For your safety, please readthe following text carefully.
This applianceissupplied with a moulded three-pin mains plugfor your safety and convenience.A 5-ampere fuse is fitted inthis plug.Should the fuse need tobe replaced please ensurethat thereplacement fuse has arating of 5 amperes and it is approvedby ASTA or BSI to BS1362Check for the ASTA mark or the BSI mark on the body of thefuse.
2.3.2.1.Important
The wires in this mains lead are coloured in accordance with
the following code:
BlueNeutral
BrownLive
As the colours of the wires in the mains lead ofthis appliancemay not correspond with the coloured markings identifying theterminals in your plug, proceedasfollows:
The wire which is coloured BLUE must be connected to the ter-minal in the plug which is marked with the letter N or colouredBLACK.
The wire which iscoloured BROWN must be connected to theterminal inthe plug whichismarkedwiththe letter L or colouredRED.
Under no circumstances should either of these wires becon-nected to the earth terminal of the three pin plug, marked withthe letterE or theEarth Symbol.
2.3.2.2.Before Use
Remove the Connector Cover as follows.
If the plug contains a removable fuse cover you must ensurethat it is refittedwhen the fuse is replaced.If youlose the fuse cover, the plug must not be used until areplacement cover is obtained.A replacement fuse cover can bepurchased from your localPanasonic Dealer.
If the fitted moulded plug is unsuitable for the socket outlet inyour homethenthefuse should be removedand the plugcutoff and disposed of safety.There is a danger ofsevere electrical shock ifthe cut off plug isinsertedinto any 13-ampere socket.
If a new plug is to be fitted please observe the wiring code asshown below.If in any doubt, please consult a qualified electrician.
2.3.2.3.How to Replace the Fuse
1.Remove the Fuse Cover with a screwdriver.
2.Replace the fuseand attach theFuse cover.
5
2.4.How to Replace the Lithium Battery
2.4.1.Replacement Procedure
1. Remove the MONITOR P.C.B.. (Refer to Disassembly Procedures.)
2. Unsolder the each soldering point of electric lead terminal for Lithium battery (Ref. No. “B501” at foil side of MONITOR
P.C.B.) and remove the Lithium battery together with electric lead terminal. Then replace it into new one.
NOTE:
TheType No. ML-614S/DN includes electric lead terminals.
NOTE:
This Lithium battery is a critical component. (Type No.: ML-614S/DN Manufactured by Energy Company, Panasonic Corporation)It must never be subjected to excessive heat or discharge.It must therefore only befitted in requirement designedspecifically for its use.Replacement batteries must be of same typeand manufacture.They must be fitted in the same manner and location as theoriginal battery, with the correct polarity contacts observed.Do not attempt tore-charge the old battery or re-use it for any other purpose.It should bedisposedof in waste products destined for burial rather thanincineration.
NOTE:
Above caution is applicable for a battery pack which is for HC-V270/V260 series, as well.
6
3Service Navigation
3.1.Introduction
This service manual contains technical information, which allow service personnel’s to understand and service this model.
Please place orders using the parts list and not the drawing reference numbers.
If the circuit is changed or modified, the information will be followed by service manual to be controlled with original service manual.
3.2.General Description About Lead Free Solder (PbF)
The lead free solder has been used in the mounting process of all electricalcomponents on the printed circuit boards usedfor thisequipment inconsidering the globally environmentalconservation.The normal solder is the alloy of tin (Sn) andlead (Pb). Ontheother hand, the lead freesolder is the alloy mainly consistsof tin(Sn), silver (Ag) and Copper (Cu), and the meltingpoint of the leadfree solder is higher approx.30°C (86°F) more thanthat of thenormal solder.
Distinctionof P.C.B. Lead Free Solder being used
Service caution for repair work using Lead Free Solder (PbF)
•The leadfreesolder has tobe used when repairing the equipment for which the leadfreesolder is used.(Definition: The letter of “PbF” is printed on the P.C.B. using the leadfreesolder.)
•To put leadfree solder, it should be wellmoltenand mixed with the original lead free solder.
•Removethe remaininglead free solder on the P.C.B. cleanly for solderingof the newIC.
•Since the melting point of the lead free solder is higher than that of the normal lead solder, it takes the longer time to melt thelead freesolder.
•Use the soldering iron (more than 70W) equipped with the temperature control after setting the temperature at 350±30°C(662±86°F).
RecommendedLead Free Solder(Service Parts Route.)
•The following 3 types of lead free solderareavailable through the service parts route.SVKZ000001-----------(0.3mm 100g Reel)SVKZ000002-----------(0.6mm 100g Reel)SVKZ000003-----------(1.0mm 100g Reel)
3.3.How to Define the Model Suffix (NTSC or PAL model)
There are eight kinds of HC-V270/V260.
• a) HC-V360M (Japan domestic model)
• b) HC-V270PP
• c) HC-V270EB/EC/EF/EG/EP
• d) HC-V270EE
•e) HC-V260EE
•f) HC-V270GK
•g) HC-V270GN
•h) HC-V270PU/GC/GW
What isthe difference is that the “INITIALSETTING” data which is stored inFlash ROM mounted onMain P.C.B..
3.3.1.Defining methods:
To define the model suffix tobeserviced, refer to the rating label and caution label which are putted on the Unit.
NOTE:
After replacing the MAIN P.C.B., be sure toachieveadjustment.
8
3.4.Formatting
The following formatting is for HC-V270PP.
The page number in this page does not show the page number of this service manual.
9
3.5.Baking of replacement IC and defective P.C.B.
When replacing the CSP/BGA/QFN type IC mounted on the P.C.B., the problem of IC crack or foil pattern breaking in the P.C.B.
might sometimes occur by rapid heating.
In order to improve the success rate of IC replacement for repair, it would be required to work out baking of replacement
IC and defective P.C.B. before replacing IC.
Please refer the way of baking as follows.
Replacement IC anddefectiveP.C.B. must be put in the heatertogether.
•Baking temperature and time (Hour)80°C / 24 hour
10
4Specifications
The following specification is for HC-V270PP.
Some specifications may differ depending on model suffix.
The page number in this chapter does not show the page number of this service manual.
11
12
5Location of Controls and Components
The following description is for HC-V270PP.
Some descriptions may differ depending on model suffix.
The page number in this chapter does not show the page number of this service manual.
13
141516
6Service Mode
Indication method of the service menu
1. Keep pressing the “Power” button, “Zoom lever” to W side and “Recording/Playback” button for more than 3 seconds until the
top screen of the Service Mode Menu being displayed.
Service mode menu
Screen displayContentsFunction
1Factory settingsFunction to throw a product up in a factory shipment state.2Model/Destination settingsChange the Model/Destination.
4Lock search history indicationDisplay the camerasystem error cord for three histories saved in
5Power ON self check result displayPowerON self check (function to diagnose correct function of the
14Adjutment function for the serviceThe service adjustment do setup and adjustment of the following
15Restore the backed upadjustment dataRestore the adjustment data to new or repaired Main P.C.B. from
16Touch panel calibrationCalibrate the touch positions of the touch panel.17NFC initialization
(HC-V270 only)
(Selectable models and destinations are displayed.)
EEPROM.
device and interface between devices) result display.
items required in the field service.
SD card that the data backed up from original Main P.C.B. beforerepairs or replacement.
Performs the Initialization of the NFC chip and erase the settingslike as Wi-Fi connection etc..
NOTE:
Donot using service mode exceptabove table of Service mode menu.
2.Endmethod of the top screen of the service mode menu
Touch the [ EXIT ] ofLCD to end the service mode, and then POWER OFF.
6.1.Model/Destination Settings
Touch the [ 2 ] of LCD, select model/destination settings.
Operation specifications
Function description
•Change the Model/DestinationDisplay the lists of model/distination which the unit can be changed, if ashipment setup is finished.Therefore in some cases, themodel/destination that is currently set is only displayed.
End method of operation
•Touch the [ SET ] of LCD to exit the mode/destination settings, and then POWER OFF.
17
6.2.Lock Search and Error History Indication
Touch the [ 4 ] of LCD, select Lock search and error history indication.
Operation specifications
Indication contents
•Lock search history indicationDisplay the camera system error cord for three histories saved in EEPROM.
•The error cord contents which aredisplayed
Error codeDescriptionProblematic Parts
51Focus control is abnormalFOCUS STEPPING MOTOR / LENS UNIT52Zoom control is abnormal2ND STEPPING MOTOR / LENS UNIT53OIS lens control is abnormalLENS UNIT54Zoom control is abnormal (2)3RD STEPPING MOTOR / LENS UNIT
End method of operation
•Touch the [ BAK ] of LCD to exit the lock search and error history indication, and then POWER OFF.
18
6.3.Power ON Self Check Result Display
Touch the [ 5 ] of LCD, select Power ON self check result display.
Operation specifications
Indication contents
•Power ON self check result displayFunction to diagnose correct function of thedevice andinterfacebetweendevices result display.
Display the following communication test result.
-Power IC : Communication test between IC3401 and IC1503
-MainIC : DDR. Communication test between IC3401 and IC3402/IC3403
-WiFiIC : Communication test between IC3401 andWi-Fi P.C.B.. (HC-V270 only)
-NFC IC : Communication test betweenIC3401 and NFC P.C.B. unit. (HC-V270 only)
Display other than “OK” are abnomalities of each lines.
-PanTilter : Error display of the Remote Pan Tilt Cradle(VW-CTR1)(When not connected the remote pan tilt cradle, display “--”.)When error is occurred, display “NG” with the error code.
Error CodeDescription
NG 01Battery undercutNG 04The start-up state of the update error factorNG 10The failure of Tilt motorNG 80USBCommunication Error
End method of operation
•Touch the [ BAK ] of LCD to exitthe power on self check result display, and the POWER OFF.