Panasonic FV-08VKME3 User Manual

FV-08VKME3
FV-08VKSE3
Panasonic
INSTALLATION INSTRUCTIONS
Ventilating Fan
Model No. FV-08VKME3 FV-08VKSE3
Contents
General Safety Information............................................... 2-3
Description
Unpacking ............................................................................. 5
Supplied Accessories .......................................................... 5
Dimensions............................................................................ 6
Wiring Diagram
Switch Indication................................................................... 7
Operation....................................................................... 7
Installation I (Joist Mounting -1) Installation II (Suspension Brackets Mounting)— 10 Installation III (Joist Mounting - II) Maintenance
Practical Guide To Installation...............................Back cover
Specifications Product Service
...........................................................................
.....................................................................
.......................................
........................................
.........................................................................
.........................................................
.......................................................
..........................
Back cover
Back cover
4 5
6
8-10
11 11
READ AND SAVE THESE INSTRUCTIONS
Thank you for purchasing this Panasonic product. Please read these instructions carefully before attempting to install, operate or service the Panasonic product. Failure to comply with instructions could result in personal injury or property damage. Please explain to users how to operate and maintain the product after installation, and this booklet should be presented to users. Please retain this booklet for future reference.
GENERAL SAFETY INFORMATION

For Your Safety

To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or pro always observe the following safety precautions.

Explanation of symbol word panels

The following symbol word panels are used to classify and describe the level of hazard, injury, and
property damage caused when the denotation is disregarded and improper use is performed.
Denotes a potential hazard that could result in serious
Awarning
injury or death.
Acaution
The following symbols are used to classify and describe the type of instructions to be observed.
This symbol is used to alert users to a specific operating procedure that must not be
0
o
performed. This symbol is used to alert users to a specific operating procedure that must be followed
in order to operate the unit safety.
Denotes a hazard that could result in minor injury.
Awarning
/
To reduce the risk of fire, electric shock or injury to persons, observe the following :
Use this unit only in the manner intended by the manufacturer. If you have any questions,
contact the manufacturer.
Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switch on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
O
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's
O
guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHFÎAE) and the local code authorities.
o
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other
hidden utilities. Ducted fans must always be vented to the outdoors.
o
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the
application and be connected to a GFCI(Ground Fault Circuit Interrupter) - protected branch circuit.
These models are LIL listed for tub and shower enclosures.
GENERAL SAFETY INFORMATION CONTINUED
Awarning
0
Do not use this fan with any solid-state speed control device.
Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40.
Do not disassemble the unit for reconstruction.
0
A statement to the effect that when the product is to no longer be used, it must not be left in
place but removed, to prevent it from possibly falling.
O
Ceiling joist must be subjected to static load more than five times the weight of the product.
0
Do not install with a method which is not approved in the instrucions.
This product must be properly grounded.
Acaution
Do not install this ventilating fan where interior room temperature may
exceed 104°F(40°C).
o
Make sure that the electric service supply voltage is AC 120V, 60 Hz.
o
Follow all local electrical and safety codes, as well as the National
o o
o
Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA). Always disconnect the power source before working on or near the fan, prohibited
motor, light fixture or junction box. Protect the supply wiring from sharp edges, oil, grease, hot surfaces,
chemicals or other objects. Do not kink the supply wiring.
o
o
Provide make up air for proper ventilation. For general ventilating use only. Do not use to exhaust hazardous or
o
0 0
explosive materials and vapors. Do not install the unit where ducts are configured as shown
in Fig.A.
Not for use in cooking area. (Fig.B)
The special-purpose or dedicated parts, such as mounting fixtures, must be used if such parts are provided.
o
n-4-
Q ^
Prohibited
Gw
’rohibrted

0QZ=D

Prohibited
0
Prohibited
Fig. A
(Cooking area)
Do not install above or
inside this area
\
Cooking
equipment
Fig.B
jL
Adaptor
/
/
Floor
/
/
PLEASE READ PRIOR TO INSTALLING THIS FAN
The WhisperGreen line of ventilating fans employs state of the art technology providing a number of unique features that lead to improved indoor air quality. These features need to be fully understood prior to installation to full realize the benefits fans offer.
Spot and Continuous Ventilation: These fans are designed to run continuously ensuring a healthy environment at low CFM levels 24 hours a day. By utilizing Customvent variable speed control the fans are built to run continuously at a pre-set lower level (0,30,40,50,60,70 CFM). The setting
is dependent on the size of the room and the individual wishes of the homeowner. It is crucial
that the installer pre-set the lower setting during the installation. Please refer to the chart below and the switch indication on page 7.
CustomVent Variable Speed Control (Lower Setting).
ASHRAE 62.2-2007
________________
(sq.feet) < 1, 000 33 40 48 55
1,500 38 45 53 60 2,000 43 50 58 65 2,500 48 55 63 70 3,000 53 60 68 3,500 4,000 63 70 78 4,500 5,000 5,500 6,000 6,500 7,000
These fans are also built to take care of the homeowner's spot ventilation needs when the room is occupied. This models kick-up to a maximum level of 80 CFM either when the switch is turned on
(available with FV-08VKSE3) or activated by the SmartAction Motion Sensor(available with
FV-08VKME3).
A High / Low Delay Timer, located inside the fan unit, is utilized to return the fan back to the pre-set Continuous ventilation mode. The installer needs to consult with the homeowner for the desired setting on the timer (0.5 - 60 minutes) and make the adjustments during the installation.
Optimum Ventilation Performance: Generally duct length, elbows and other factors increase static
pressure hindering the performance of most ventilation fans. This fan utilize SmartFlow microchip technology that monitors the static pressure in the system and speeds up or slows down the rpm of the fan depending on the amount of resistance. This allows the fan to perform as rated, whether facing
0.1,0.2 or even 0.25 inches water gauge. The bottom line is that it makes for easier installation. The installer no longer has to worry about compromising the fan's performance.
Two Bedrooms Three Bedrooms Four Bedrooms Five Bedrooms
75
58 65 73 68 75 83
73 80 88 78 85 93 83 90 98 88 95 103 93 100 108
80 85 90
95 100 105 110
-
Outstanding Energy Savings: These fans are the very first to be built using DC motor technology.
The new DC motor is 30% - 70% more energy efficient than the minimum ENERGY STAR requirements.
4
Loading...
+ 8 hidden pages