Panasonic FV-08VKML3, FV-08VKL3, FV-08VKSL3, FV-13VKML3, FV-13VKL3, FV-13VKSL3 service manual
PEG1009014CE
Version:1101
ServiceManual
Super Quiet Ventilating Fan/Light Combination
TM
Whisper Green-Lite
(North American Market)
FV-08VKML3
FV-08VKL3
FV-08VKSL3
FV-13VKML3
FV-13VKL3
FV-13VKSL3
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by
the general public. It does not contain warnings or cautions to advise non-technical individuals of potential
dangers in attempting to service a product. Products powered by electricity should be serviced or repaired
only by experienced professional technicians. Any attempt to service or repair the product or products dealt
with in this service information by anyone else could result in serious injury or death.
IMPORTANT SAFETY NOTICE
There are special components used in this equipment which are important for safety. These parts are
marked byin the Schematic Diagrams, Exploded Views and Replacement Parts List. It is essential
that these critical parts should be replaced with manufacturer's specified parts to prevent shock, fire
or other hazards. Do not modify the original design without permission of manufacture.
We suggest to handle such parts after the static electricity prevention.
It is forbidden to touch the PCB parts by bare hands during the repairing process.
CONTENTS
1. Specifications
2. Parts Identification
3.Wiring Diagram
4. Parts List
PAGE
1
2~7
8
9~20
1.Specifications
1
2.Parts Identification
Main Body Section
B
6
C
(3pcs)
FV-08VKML3
1
2
A
(2pcs)
7
5
A
3
4
Details Of Wiring Section
F
(4pcs)
22
E
(2pcs)
21
F
(4pcs)
Main PCB Section
G
23
25
26
51
50
E
20
24
(50)
12
A
11
(4pcs)
C
15
16
17
B
(3pcs)
14
(2pcs)
D
9
10
13
E
VentilatingFan
ModelNo.
AC120V60Hz 0.33A Fan 0.53ALight
PanasonicCorporation ofNorth America
Madein China /Fabrique en Chine
1.Not for use in cooking area-See installation instructions
1.Non destine a la zone de cuisson-Voir instructions d installation
2.Type IC-Inherently Protected
2.Type IC-Protection Intrinseque
3.Suitable for use with motor Model 13KML3M20
30
3.Approprie pour une utilisation avec le moteur
Modele13KML3M20
A
CAUTION:
To reducethe risk ofinjury to persons,installfan at least
2.1m(7feet)above thefloor.
ATTENTION:
Afin dereduire les risquesde blessures corporelles,
Installer leventilateur a aumoins 2,1m(7 pieds)dusol.
FV-08VKML3
() ( )
Ventilateur
29
31
8
(3pcs)
LISTEN
A375682G8
US
FAN
8B68
33
C
34
32
E
(5pcs)
12
35
mm
Inch
36
1
_
2
2
60
2
50
40
1
_
1
2
30
1
20
1
_
2
10
37
Main Labels
(Stuck On Frame Assy)
39
40
38
41
42
43
44
14
19
45
46
47
27
52
28
Grille Assy Section
18
E
(2pcs)
48
49
53
Main Packing Materials
2
2.Parts Identification
Main Body Section
B
6
C
(3pcs)
FV-08VKSL3
1
2
A
(2pcs)
7
5
A
3
4
Details Of Wiring Section
F
(4pcs)
22
E
(2pcs)
21
F
(4pcs)
Main PCB Section
G
23
25
26
49
E
20
24
(49)
12
A
11
(4pcs)
C
15
16
17
B
(3pcs)
12
(2pcs)
D
9
10
13
E
VentilatingFan
ModelNo.
AC120V60Hz 0.33A Fan 0.53A Light
PanasonicCorporation ofNorth America
Madein China /Fabrique en Chine
1.Not for use in cooking area-See installation instructions
1.Non destine a la zone de cuisson-Voir instructions d installation
2.Type IC-Inherently Protected
2.Type IC-Protection Intrinseque
30
3.Suitable for use with motor Model 13KML3M20
3.Approprie pour une utilisation avec le moteur
Modele13KML3M20
A
CAUTION:
To reducethe risk ofinjury to persons,installfan at least
2.1m(7feet)above thefloor.
ATTENTION:
Afin dereduire les risquesde blessures corporelles,
Installer leventilateur a aumoins 2,1m(7 pieds)dusol.
FV-08VKSL3
() ( )
Ventilateur
29
31
8
(3pcs)
LISTEN
A375682G8
US
FAN
8B68
33
C
34
32
E
(5pcs)
()
VENT.
(Powersupply/
Alimentation
electrique)
(Powersupply/
Alimentation
electrique)
()
N.LIGHT
()
LIGHT
35
mm
Inch
36
1
_
2
2
60
2
50
40
1
_
1
AC120V
60Hz/
120VCA
60Hz
AC120V
60Hz/
120VCA
60Hz
AC120V
60Hz/
120VCA
60Hz
30
20
10
37
2
1
1
_
2
12
Fanbody/Boite du ventilateur
Maincontrol circuit/
Circuitde commande principal
Black/Noir
DC-
White/Blanc
Motor/
DC-
Blue/Bleu
Moteur
Red/Rouge
Airvolume/
Debitd air
Lightingunit/Appareil d eclairage
Black/Noir
Night
lamp/
White/Blanc
Veilleuse
Blue/Bleu
Blue/Bleu
Flourescent
lamp/Ampouleflourescente
Wiringdiagram/Schema de connexions
Junctionbox/Boite de raccordement
Black/Noir
White/Blanc
Green/Vert
Red/Rouge
Black/Noir
Yellow/Jaune
Red/Rouge
White/Blanc
Adjustment
switch/
Commutateur
Delaytime/
dereglage
Laminuterie
Black/Noir
White/Blanc
White/
Blanc
Electronic
Blue/Bleu
ballast/
Black/
Blue/Bleu
Ballast
Noir
Red/RougeRed/Rouge
Red/RougeRed/Rouge
Switchbox/Boite
decommutation
Black/
Live/Sous
tension
Noir
ON
Neutral/
White/
Neutre
Blanc
Red/
Rouge
Hi
Red/
Rouge
(Earthground/
Green/
Misea la terre)
Vert
Switchbox/Boite
decommutation
Live/Sous
Black/
tension
Noir
ON
Neutral/
White/
Neutre
Blanc
Black/
Live/Sous
tension
Noir
ON
Main Labels
(Stuck On Frame Assy)
39
40
38
41
42
43
44
14
19
45
46
47
27
28
Grille Assy Section
18
E
(2pcs)
48
50
Main Packing Materials
3
2.Parts Identification
Main Body Section
B
6
C
(3pcs)
FV-13VKML3
1
2
A
(2pcs)
7
5
A
3
4
Details Of Wiring Section
F
(4pcs)
22
E
(2pcs)
21
F
(4pcs)
Main PCB Section
G
23
25
26
51
50
E
20
24
10
(50)
A
11
C
(3pcs)
9
15
16
17
B
14
E
(2pcs)
VentilatingFan
ModelNo.
AC120V60Hz 0.45A Fan 0.53A Light
PanasonicCorporation ofNorth America
Madein China /Fabrique en Chine
1.Not for use in cooking area-See installation instructions
1.Non destine a la zone de cuisson-Voir instructions d installation
2.Type IC-Inherently Protected
2.Type IC-Protection Intrinseque
3.Suitable for use with motor Model 13KML3M20
30
3.Approprie pour une utilisation avec le moteur
Modele13KML3M20