Panasonic EX-F70, EX-F60, EX-F71, EX-F71-PN, EX-F72 Ordering Manual

...
853
<When leakage occurs>
<When there is no leakage>
Leak Detection Sensor
Amplier Built-in
EX-F70 SERIES EX-F60 SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
Related Information
■General terms and conditions ........... F-17
■General precautions ..................... P.1405
panasonic-electric-works.net/sunx
■Sensor selection guide ................. P.831~
■Korea’s S-mark ............................. P.1410
Conforming to EMC Directive
Certified
(Excluding PNP output type)
Recognition
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
High-speed detection even a little liquid leak
EX-F70 SERIES
Reliable detection
The unique effect of capillarity enables reliable detection of small leaks and viscous liquids.
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
New type of detection method
When a leak occurs, the beam from the beam-emitting part scatters through the leaked liquid and is not transmitted to the beam-receiving part.
Selection
Guide
Wafer Detection
Liquid Leak
Detection
Liquid Level
Detection
Water Detection
Color Mark
Detection
Hot Melt Glue
Detection
Ultrasonic
Small /
Slim Object Detection
Obstacle
Detection
Other Products
SQ4
EX-F70/
EX-F60
Beam-emitting part Beam-receiving part
Leaked liquid
The beam from the beam-emitting part scatters through the leaked liquid and is not transmitted to the beam-receiving part.
Compact, space-saving
This slim (10 mm 0.394 in) side-mounting sensor is especially good for use
in conned spaces.
Sensing surface
Leakage pan
Capillarity effect
Liquid
Leakage panLeakage pan
Beam-emitting part Beam-receiving part
Leakage pan
The beam from the beam-emitting part reflects off of the surface of the sensor and is transmitted to the beam-receiving part.
Sensor body
Sensing surface
10 mm
0.394 in
approx.
No need for sensitivity adjustment
No need for sensitivity adjustment with adjuster, so initial mounting is easy.
Easy operation check
This sensor is equipped with a NORMAL indicator (green) which lights up when mounting correctly, and a FAULT indicator (red) which lights up when sensing the leaked liquid or when mounted incorrectly (forgetting to mount exclusive mounting bracket). So, the operation can be checked easily.
Safe design
If the sensor is not mounted correctly, if the cable is broken or disconnected, or if the sensor is not operating correctly, the output is the same as when the beam is not received (LEAK). Design deals with human errors such as, forgetting to mount, etc.
Easy installation & reset
Facilitates easy installation: the SUS mounting bracket type can be installed using only a single screw and the PVC mounting bracket type can be installed using only two screws or an adhesive. No component replacement required for resetting after leak detection. The simple shape makes it easy to wipe off the leaked liquid.
PVC mounting bracket available
EX-F72
SUS mounting bracket type
EX-F71
PVC mounting bracket type
A mounting bracket made of PVC (polyvinyl chloride) is available. This mounting bracket can be used normally in environments that would corrode normal metal brackets.
EX-F72
Leak Detection Sensor EX-F70 SERIES EX-F60 SERIES
854
EX-F60 SERIES
PFA enclosure gives excellent chemical resistance
The sensor enclosure and the cable sheath are made from PFA which is highly resistant to chemicals. Accurate sensing is achieved even if there are leaks of chemicals such as sulfuric acid, hydrochloric acid or ammonia.
PFA coating
PFA case
Compact, space-saving
Even with its built-in
amplier, the size is
compact at W26 × H19 × D9 mm W1.024 × H0.748
× D0.354 in, so that it can
be used even in narrow spaces.
Easy installation & reset
The simplied shape makes it easy to clean up after liquid
leaks, simply by wiping off the liquid, and no parts need to be replaced.
EX-FC1
Wire-saving unit made especially for connecting leak detection sensors!
Saves wiring! Now connects up to 8 leak detection sensors
EX-FC1 is a simple wire-saving unit for exclusive use with EX-F71/F72, EX-F61/F62 leak detection sensors.
(It can be used with general sensors as well.) EX-FC1 integrates the outputs from up to 8 leak detection
sensors into a single OR output, so signicant wiring and
space savings are achieved. * Even with only one leak detection sensor connected, an
OFF signal is output if the sensor detects liquid leakage, or if the unit has been installed incorrectly.
Slim & compact
Space savings are signicant, as the ultra-thin & compact
EX-FC1 has main unit body dimensions of only W20 × H80 × D52 mm W0.787 × H3.150 × D2.047 in.
Connects easily with one-touch connector
Connections are made by simply inserting the leak detection sensor cable leads into the snap male connector SL-CP1, then push until the connector snap-locks! This saves the time and the trouble of stripping the insulation from each lead before attaching to terminals.
ORDER GUIDE
Leak detection sensors
Type Appearance Sensing object Cable length Model No. Output
SUS mounting bracket type
Water, Fluorinert (Note 1, 2)
PVC mounting
General purpose
bracket type
PFA mounting bracket type
PVC mounting
Chemical-resistant
bracket type
Notes: 1) Highly viscous liquid may not be detected stably.
2) Fluorinert
3) The agents mentioned above are examples.
TM
is the world wide trademark of 3M.
For details, please contact our ofce.
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. (Note 1, 3)
5 m 16.404 ft cable length type
5 m 16.404 ft cable length type (standard: 2 m 6.562 ft or 3 m 9.843 ft) is also available. When ordering this type, sufx “-C5” to the model No.
5 m 16.404 ft cable length type of EX-F71-PN is “EX-F71-PN-C5
(e.g.)
TM
2 m 6.562 ft
3 m 9.843 ft
Simple wire-saving unit for leak detection sensor
Appearance Model No. Output
.
EX-F71
EX-F71-PN
EX-F72
EX-F72-PN
EX-F61
EX-F61-PN
EX-F62
EX-F62-PN
EX-FC1
9 mm
9 mm
0.354 in
0.354 in
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
Relay contact 1 a
26 mm 1.024 in 26 mm 1.024 in
19 mm 0.748 in
19 mm 0.748 in
FIBER SENSORS
LASER SENSORS
PHOTO­ELECTRIC SENSORS
MICRO PHOTO­ELECTRIC SENSORS
AREA SENSORS
LIGHT CURTAINS
PRESSURE / FLOW SENSORS
INDUCTIVE PROXIMITY SENSORS
PARTICULAR USE SENSORS
SENSOR OPTIONS
SIMPLE WIRE-SAVING UNITS
WIRE-SAVING SYSTEMS
MEASURE­MENT SENSORS
STATIC CONTROL DEVICES
ENDOSCOPE
LASER MARKERS
PLC / TERMINALS
HUMAN MACHINE INTERFACES
ENERGY CONSUMPTION VISUALIZATION COMPONENTS
FA COMPONENTS
MACHINE VISION SYSTEMS
UV CURING SYSTEMS
Selection Guide
Wafer Detection
Liquid Leak Detection
Liquid Level Detection
Water Detection
Color Mark Detection
Hot Melt Glue Detection
Ultrasonic
Small / Slim Object Detection
Obstacle Detection
Other Products
SQ4
EX-F70/ EX-F60
855
Connector end caps
Leak Detection Sensor EX-F70 SERIES EX-F60 SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO­ELECTRIC SENSORS
ELECTRIC SENSORS
SENSORS
CURTAINS
PRESSURE /
SENSORS
INDUCTIVE PROXIMITY
SENSORS
PARTICULAR
SENSOR
OPTIONS
WIRE-SAVING
WIRE-SAVING
MEASURE-
SENSORS
CONTROL
DEVICES
ENDOSCOPE
MARKERS
TERMINALS
INTERFACES
CONSUMPTION VISUALIZATION
COMPONENTS
COMPONENTS
MACHINE
SYSTEMS
CURING
SYSTEMS
Unit mounting bracket
MICRO
PHOTO-
Accessories
AREA
•MS-EX-F7-1
LIGHT
FLOW
USE
SENSORS
SIMPLE
UNITS
SYSTEMS
Sensors
MENT
STATIC
Item
LASER
Sensing object Water, Fluorinert
PLC /
Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less
HUMAN
Current consumption 10 mA or less (PNP output type: 15 mA or less) 15 mA or less
MACHINE
ENERGY
Output
FA
VISION
UV
Response time 50 ms or less
FAULT indicator Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly)
Selection
Detection
Liquid Leak
Liquid Level
Detection
Color Mark
Detection
Hot Melt Glue
Ultrasonic
Object Detection
Obstacle
Detection
Products
EX-F70/
EX-F60
NORMAL indicator Green LED (lights up when the sensor is mounted properly)
Guide
Pollution degree 3 (Industrial environment)
Wafer
Protection IP67 (IEC)
Detection
Ambient temperature
Detection
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Water
Ambient illuminance Incandescent light: 1,000 ℓx at the light-receiving face
Emitting element Infrared LED (non-modulated)
Material Enclosure: Polypropylene Enclosure: PFA
Detection
Cable 0.1 mm
Small / Slim
Cable extension Extension up to total 50 m 164.042 ft is possible with 0.3 mm
Weight Net weight: 25 g approx. Net weight: 60 g approx.
Other
Accessories
SQ4
Notes: 1) Where measurement conditions have not been specied precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
OPTIONS
Unit mounting bracket
Designation Model No. Description
MS-DIN-3
Mounting bracket for EX-FC1
•MS-EX-F7-2 •MS-EX-F6-1 •MS-EX-F6-2 •SL-CP1
SUS mounting bracket
PVC mounting bracket
for adhesive xing
PFA mounting bracket
PVC mounting bracket
MS-EX-F7-3
PVC mounting bracket
for two-point xing
(Snap male connector)
10 pcs. per set
3
2
1
•MS-DIN-3
•SC-PK
(Connector end caps)
8 pcs. per set
SC-PK
4
SPECIFICATIONS
Type
SUS mounting bracket type PVC mounting bracket type PFA mounting bracket type PVC mounting bracket type
NPN output EX-F71 EX-F72 EX-F61 EX-F62
PNP output EX-F71-PN EX-F72-PN EX-F61-PN EX-F62-PN
Model No.
<NPN output type>
NPN open-collector transistor
Maximum sink current: 50 mA
Applied voltage: 30 V DC or less (between output and 0 V)
Residual voltage: 1.0 V or less (at 50 mA sink current)
Utilization category DC-12 or DC-13
Output operation In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
Short-circuit protection Incorporated
–10 to +60 °C +14 to +140 °F (No dew condensation or icing allowed), Storage: –20 to +70 °C – 4 to +158 °F (Note 5)
MS-EX-F7-1
(SUS mounting bracket) (Note 7): 1 pc.
2) Highly viscous liquid may not be detected stably.
3) Fluorinert
TM
is the world wide trademark of 3M.
4) The agents mentioned above are examples. For details, please contact our ofce.
5) Liquid being detected should also be kept within the rated ambient temperature range.
6) PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our ofce.
7) The mounting bracket for EX-F71(-PN) is not interchangeable with that of EX-F72(-PN) due to the different sensitivity settings of each sensor.
General purpose Chemical-resistant
TM
(Note 2, 3)
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. (Note 2, 4, 6)
<PNP output type>
PNP open-collector transistor
Maximum source current: 50 mA
Applied voltage: 30 V DC or less (between output and +V)
Residual voltage: 1.0 V or less (at 50 mA source current)
0.4 V or less (at 16 mA sink current)
2
3-core PVC cabtyre cable, 2 m 6.562 ft long 0.1 mm2 3-core PFA cabtyre cable, 3 m 9.843 ft long
MS-EX-F7-2, MS-EX-F7-3 (PVC mounting bracket) (Note 7):1 pc.
each for two-point-xing and adhesive-xing
MS-EX-F6-1
(PFA mounting bracket): 1 pc.
0.4 V or less (at 16 mA source current)
2
, or more, cable.
MS-EX-F6-2
(PVC mounting bracket): 1 pc.
•MS-SL-2
Unit mounting base
Loading...
+ 7 hidden pages