Panasonic CS-E7NKR, CS-E15NKR, CS-E9NKR, CS-E12NKR, CS-E18NKR Service Manual

...
© Panasonic Appliances Air-Conditioning (M) Sdn. Bhd. 2012. Unauthorized copying and distribution is a violation of law.
Order No: PAPAMY1207090CE
Indoor Unit Outdoor Unit CS-E7NKR CS-E9NKR CS-E12NKR CS-E15NKR CS-E18NKR CS-E21NKR CS-E24NKR CS-E28NKR
CU-E7NKR CU-E9NKR CU-E12NKR CU-E15NKR CU-E18NKR CU-E21NKR CU-E24NKR CU-E28NKR
PRECAUTION OF LOW TEMPERATURE
In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit.
This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the products dealt with in this service information by anyone else could result in serious injury or death.
WARNING
2
TABLE OF CONTENTS
1. Safety Precautions.............................................3
2. Specification.......................................................5
3. Features.............................................................29
4. Location of Controls and Components..........30
4.1 Indoor Unit..................................................30
4.2 Outdoor Unit...............................................30
4.3 Remote Control ..........................................30
5. Dimensions.......................................................31
5.1 Indoor Unit..................................................31
5.2 Outdoor Unit...............................................33
6. Refrigeration Cycle Diagram...........................35
6.1 CU-E7NKR.................................................35
6.2 CU-E9NKR CU-E12NKR...........................36
6.3 CU-E15NKR CU-E18NKR.........................37
6.4 CU-E21NKR...............................................38
6.5 CU-E24NKR CU-E28NKR.........................39
7. Block Diagram ..................................................40
7.1 CU-E7NKR CU-E9NKR CU-E12NKR......40
7.2 CU-E15NKR CU-E18NKR
CU-E21NKR...............................................41
7.3 CU-E24NKR...............................................42
7.4 CU-E28NKR...............................................43
8. Wiring Connection Diagram............................44
8.1 Indoor Unit..................................................44
8.2 Outdoor Unit...............................................45
9. Electronic Circuit Diagram..............................50
9.1 Indoor Unit..................................................50
9.2 Outdoor Unit...............................................51
10. Printed Circuit Board.......................................56
10.1 Indoor Unit..................................................56
10.2 Outdoor Unit...............................................59
11. Installation Instruction.....................................64
11.1 Select the Best Location.............................64
11.2 Indoor Unit..................................................65
11.3 Outdoor Unit...............................................69
12. Installation Instruction.....................................72
12.1 Select the Best Location.............................72
12.2 Indoor Unit..................................................73
12.3 Outdoor Unit...............................................77
13. Operation Control.............................................80
13.1 Basic Function............................................80
13.2 Indoor Fan Motor Operation.......................81
13.3 Outdoor Fan Motor Operation....................82
13.4 Airflow Direction..........................................83
13.5 Quiet operation (Cooling Mode/Cooling area
of Dry Mode)...............................................84
13.6 Quiet operation (Heating)...........................84
13.7 Powerful Mode Operation...........................85
13.8 Timer Control..............................................85
13.9 Auto Restart Control...................................85
13.10 Indication Panel......................................... 86
13.11 nanoe-G Operation.................................... 86
13.12 Mild Dry Cooling Operation ....................... 88
13.13 AUTO COMFORT and ECO NAVI
Operation................................................... 88
14. Protection Control........................................... 97
14.1 Protection Control For All Operations........ 97
14.2 Protection Control For Cooling & Soft Dry
Operation................................................... 99
14.3 Protection Control For Heating
Operation................................................. 100
15. Servicing Mode.............................................. 102
15.1 Auto OFF/ON Button............................... 102
15.2 Remote Control Button............................ 103
16. Troubleshooting Guide................................. 105
16.1 Refrigeration cycle system ...................... 105
16.2 Breakdown Self Diagnosis Function........ 107
16.3 Error Code Table..................................... 108
16.4 Self-diagnosis Method............................. 110
17. Disassembly and Assembly Instructions... 139
17.1 CS-E7NK CS-E9NK CS-E12NK
CS-E15NK............................................... 139
17.2 CS-E18NK CS-E21NK CS-E24NK
CS-E28NK............................................... 143
17.3 Outdoor Electronic Controller Removal
Procedure................................................ 147
18. Technical Data............................................... 150
18.1 Operation Characteristics........................ 150
18.2 Sensible Capacity Chart.......................... 182
19. Exploded View and Replacement Parts
List .................................................................. 186
19.1 Indoor Unit............................................... 186
19.2 Outdoor Unit............................................ 190
3
CAUTION
WARNING
WARNING
1. Safety Precautions
Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the
power plug and main circuit for the model installed.
The caution items stated here must be followed because these important contents are related to safety. The
meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction will cause harm or damage, and the seriousness is classified by the following indications.
This indication shows the possibility of causing death or serious injury. This indication shows the possibility of causing injury or damage to properties.
The items to be followed are classified by the symbols:
Carry out test running to confirm that no abnormality occurs after the servicing. Then, explain to user the
operation, care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
1. Do not modify the machine, part, material during repairing service.
2. If wiring unit is supplied as repairing part, do not repair or connect the wire even only partial wire break. Exchange the whole wiring unit.
3. Do not wrench the fasten terminal. Pull it out or insert it straightly.
4. Engage authorized dealer or specialist for installation and servicing. If installation or servicing done by the user is defective, it will cause water leakage, electrical shock or fire.
5. Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electric shock or fire.
6. Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage, fire or electrical shock.
7. Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done, the set will drop and cause injury.
8. For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
9. This equipment is strongly recommended to install with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electrical shock and fire in case equipment breakdown or insulation breakdown.
10. Do not use joint cable for indoor/outdoor connection cable. Use the specified indoor/outdoor connection cable, refer to installation instruction CONNECT THE CABLE TO THE INDOOR UNIT and connect tightly for indoor/outdoor connection. Clamp the cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat up or fire at the connection.
11. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause heat-up or fire at the connection point of terminal, fire or electrical shock.
12. When install or relocate air conditioner, do not let any substance other than the specified refrigerant, eg. air etc. mix into refrigeration cycle (piping). (Mixing of air etc. will cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc.).
13. Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise building, child may climb up to outdoor unit and cross over the handrail and causing accident.
14. This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning rod and telephone. Otherwise, it may cause electric shock in case equipment breakdown or insulation breakdown.
15. Keep away from small children, the thin film may cling to nose and mouth and prevent breathing.
16. Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other electrical appliances. Poor contact, poor insulation or over current will cause electrical shock or fire.
17. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may break and cause refrigerant gas leakage.
18. For R410A models, when connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such same may cause abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only R410A materials. Thickness of copper pipes used with R410A must be more than 0.8mm. Never use copper pipes thinner than 0.8mm. It is desirable that the amount of residual oil is less than 40 mg/10m.
This symbol denotes item that is PROHIBITED from doing.
4
CAUTION
WARNING
19. During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing refrigeration piping and valves at opened condition will caused suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc).
20. During pump down operation, stop the compressor before remove the refrigeration piping. (Removal of compressor while compressor is operating and valves are opened will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.)
21. After completion of installation or service, confirm there is no leakage or refrigerant gas. It may generate toxic gas when the refrigerant contacts with fire.
22. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when refrigerant contacts with fire.
23. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury.
24. Must not use other parts except original parts described in catalog and manual.
25. Using of refrigerant other than the specified type may cause product damage, burst and injury etc.
1. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fire.
2. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture.
3. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may break and cause refrigerant gas leakage.
4. Do not touch outdoor unit air inlet and aluminium fin. It may cause injury.
5. Select an installation location which is easy for maintenance.
6. Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F – 70°F (30°C – 40°C) higher. Please use a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C). Pb free solder will tend to splash when heated too high (about 1100°F / 600°C).
7. Power supply connection to the air conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following methods. Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries, permanent connection of this room air conditioner to the power supply is prohibited. i. Power supply connection to the receptacle using a power plug. Use an approved 15/16A (3/4~1.75HP) or 16A (2.0HP) or 20A (2.5HP) or 25A (3.0HP) power plug with earth pin for the connection to the socket. ii. Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A (3/4~2.0HP), 20A (2.5HP) or 25A (3.0HP) circuit breaker for the permanent connection. It must be a double pole switch with a minimum 3.0 mm contact gap.
8. Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts. Take care of the liquid refrigerant, it may cause frostbite.
9. Installation or servicing work: It may need two people to carry out the installation or servicing work.
10. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
11. Do not sit or step on the unit, you may fall down accidentally.
12. Do not touch the sharp aluminium fins or edges of metal parts. If you are required to handle sharp parts during installation or servicing, please wear hand glove. Sharp parts may cause injury.
5
2. Specification
Indoor CS-E7NKR
Model
Outdoor CU-E7NKR
Performance Test Condition AS
Phase, Hz Single, 50
Power Supply
V 230 240
Min. Mid. Max. Min. Mid. Max.
kW 0.85 2.05 2.40 0.85 2.05 2.40
BTU/h 2900 6990 8180 2900 6990 8180
Capacity
kcal/h 730 1760 2060 730 1760 2060
Running Current A - 2.2 - - 2.2 -
Input Power W 200 460 590 200 460 590
W/W 4.25 4.46 4.07 4.25 4.46 4.07
BTU/hW 14.50 15.20 13.86 14.50 15.20 13.86
EER
kcal/hW 3.65 3.83 3.49 3.65 3.83 3.49
Power Factor % - 91 - - 87 -
dB-A 37 / 24 / 21 37 / 24 / 21
Indoor Noise (H / L / QLo)
Power Level dB 53 / 40 / 37 53 / 40 / 37
dB-A 45 / - / - 45 / - / -
Cooling
Outdoor Noise (H / L / QLo)
Power Level dB 60 / - / - 60 / - / -
kW 0.70 2.80 4.00 0.70 2.80 4.00
BTU/h 2390 9550 13600 2390 9550 13600
Capacity
kcal/h 600 2410 3440 600 2410 3440
Running Current A - 2.9 - - 2.8 -
Input Power W 160 620 1.02k 160 620 1.02k
W/W 4.38 4.52 3.92 4.38 4.52 3.92
BTU/hW 14.94 15.40 13.33 14.94 15.40 13.33
COP
kcal/hW 3.75 3.89 3.37 3.75 3.89 3.37
Power Factor % - 93 - - 92 -
dB-A 38 / 25 / 21 38 / 25 / 21
Indoor Noise (H / L / QLo)
Power Level dB 54 / 41 / 37 54 / 41 / 37
dB-A 46 / - / - 46 / - / -
Heating
Outdoor Noise (H / L / QLo)
Power Level dB 61 / - / - 61 / - / -
Capacity kW 2.9
Input Power W 0.90
H2
COP W/W 3.22
Capacity kW 4.10
Input Power W 1.05k
Powerful Heat
COP W/W 3.90
Max Current (A) / Max Input Power (W) 4.8 / 1.03k
Starting Current (A) 2.9
Type Hermetic Motor
Motor Type Brushless (6 poles)
Compressor
Output Power W 650
6
Type Cross-Flow Fan
Material ASG20K1 Motor Type Transistor (8-poles) Input Power W 47.3 - 47.3
Output Power W 40
Cool rpm 630
QLo
Heat rpm 650 Cool rpm 710
Lo
Heat rpm 760 Cool rpm 900
Me
Heat rpm 950 Cool rpm 1090
Hi
Heat rpm 1150 Cool rpm 1190
Indoor Fan
Speed
SHi
Heat rpm 1250
Type Propeller Fan
Material PP Motor Type DC Motor (8-poles) Input Power W -
Output Power W 40
Cool rpm 790
Outdoor Fan
Speed Hi
Heat rpm 770
Moisture Removal L/h (Pt/h) 1.3 (2.7)
Cool m3/min (ft3/min) 5.33 (188)
QLo
Heat m
3
/min (ft3/min) 5.80 (205)
Cool m3/min (ft3/min) 6.38 (225)
Lo
Heat m
3
/min (ft3/min) 7.01 (247)
Cool m3/min (ft3/min) 8.44 (298)
Me
Heat m3/min (ft3/min) 9.10 (321) Cool m3/min (ft3/min) 10.5 (370)
Hi
Heat m
3
/min (ft3/min) 11.3 (400)
Cool m3/min (ft3/min) 11.65 (411)
Indoor Airflow
SHi
Heat m3/min (ft3/min) 12.40 (438) Cool m3/min (ft3/min) 28.9 (1020)
Outdoor
Airflow
Hi
Heat m
3
/min (ft3/min) 28.9 (1020) Control Device Check Valve & Capillary Tube Refrigerant Oil cm3 FV50S (320)
Refrigeration
Cycle
Refrigerant Type g (oz) R410A, 880 (31.1) Height(I/D / O/D) mm (inch) 290 (11-7/16) / 619 (24-3/8) Width (I/D / O/D) mm (inch) 870 (34-9/32) / 824 (32-15/32)
Dimension
Depth (I/D / O/D) mm (inch) 214 (8-7/16) / 299 (11-25/32)
Weight Net (I/D / O/D) kg (lb) 9 (20) / 32 (71)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 9.52 (3/8)
Standard length m (ft) 7.5 (24.6) Length range (min – max) m (ft) 3 (9.8) ~ 15 (49.2) I/D & O/D Height different m (ft) 15 (49.2)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Piping
Length for Additional Gas m (ft) 7.5 (24.6)
7
Inner Diameter mm 16
Drain Hose
Length mm 650
Fin Material Aluminium (Pre Coat)
Fin Type Slit Fin
Row x Stage x FPI 2 x 15 x 21
Indoor Heat
Exchanger
Size (W x H x L) mm 610 x 315 x 25.4
Fin Material Aluminium (Blue Coated)
Fin Type Corrugated Fin
Row x Stage x FPI 2 x 28 x 17
Outdoor
Heat
Exchanger
Size (W x H x L) mm 36.4 x 588 x 606.6
Material Polypropelene
Air Filter
Type One-touch
Power Supply Outdoor Power Supply
Power Supply Cord A Nil
Thermostat Electronic Contol
Protection Device Electronic Contol
DRY BULB WET BULB
Maximum 32 23
Cooling
Minimum 16 11
Maximum 30 -
Indoor
Operation
Range
Heating
Minimum 16 -
Maximum 46 26
Cooling
Minimum 5 4
Maximum 24 18
Outdoor
Operation
Range
Heating
Minimum -15 -16
1. Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5. Specifications are subjected to change without prior notice for further improvement.
8
Indoor CS-E9NKR
Model
Outdoor CU-E9NKR
Performance Test Condition AS
Phase, Hz Single, 50
Power Supply
V 230 240
Min. Mid. Max. Min. Mid. Max.
kW 0.90 2.60 3.00 0.90 2.60 3.00
BTU/h 3070 8870 10200 3070 8870 10200
Capacity
kcal/h 770 2240 2580 770 2240 2580
Running Current A - 2.6 - - 2.5 -
Input Power W 210 550 780 210 550 780
W/W 4.29 4.73 3.85 4.29 4.73 3.85
BTU/hW 14.62 16.13 13.08 14.62 16.13 13.08
EER
kcal/hW 3.67 4.07 3.31 3.67 4.07 3.31
Power Factor % - 92 - - 92 -
dB-A 41 / 25 / 21 41 / 25 / 21
Indoor Noise (H / L / QLo)
Power Level dB 57 / 41 / 37 57 / 41 / 37
dB-A 46 / - / - 46 / - / -
Cooling
Outdoor Noise (H / L / QLo)
Power Level dB 61 / - / - 61 / - / -
kW 0.80 3.60 4.70 0.80 3.60 4.70
BTU/h 2730 12300 16000 2730 12300 16000
Capacity
kcal/h 690 3100 4040 690 3100 4040
Running Current A - 3.5 - - 3.4 -
Input Power W 175 750 1.23k 175 750 1.23k
W/W 4.57 4.80 3.82 4.57 4.80 3.82
BTU/hW 15.60 16.40 13.01 15.60 16.40 13.01
COP
kcal/hW 3.94 4.13 3.28 3.94 4.13 3.28
Power Factor % - 93 - - 92 -
dB-A 39 / 27 / 21 39 / 27 / 21
Indoor Noise (H / L / QLo)
Power Level dB 55 / 43 / 37 55 / 43 / 37
dB-A 46 / - / - 46 / - / -
Heating
Outdoor Noise (H / L / QLo)
Power Level dB 61 / - / - 61 / - / -
Capacity kW 3.4
Input Power W 1.09k
H2
COP W/W 3.12
Capacity kW 5.00
Input Power W 1.36k
Powerful Heat
COP W/W 3.68
Max Current (A) / Max Input Power (W) 6.2 / 1.38k
Starting Current (A) 3.5
Type Hermetic Motor (Rotary)
Motor Type Brushless (6 poles)
Compressor
Output Power W 700
9
Type Cross-Flow Fan
Material ASG20K1
Motor Type Transistor (8-poles)
Input Power W 47.3 - 47.3
Output Power W 40
Cool rpm 630
QLo
Heat rpm 690 Cool rpm 740
Lo
Heat rpm 820 Cool rpm 940
Me
Heat rpm 1010 Cool rpm 1140
Hi
Heat rpm 1200 Cool rpm 1240
Indoor Fan
Speed
SHi
Heat rpm 1300
Type Propeller Fan
Material PP
Motor Type DC Motor (8-poles)
Input Power W -
Output Power W 40
Cool rpm 800
Outdoor Fan
Speed Hi
Heat rpm 780
Moisture Removal L/h (Pt/h) 1.6 (3.4)
Cool m3/min (ft3/min) 5.33 (225)
QLo
Heat m
3
/min (ft3/min) 6.37 (225)
Cool m3/min (ft3/min) 6.58 (232)
Lo
Heat m
3
/min (ft3/min) 7.83 (276)
Cool m3/min (ft3/min) 9.12 (322)
Me
Heat m3/min (ft3/min) 9.97 (352) Cool m3/min (ft3/min) 10.9 (385)
Hi
Heat m
3
/min (ft3/min) 12.1 (425)
Cool m3/min (ft3/min) 12.24 (432)
Indoor Airflow
SHi
Heat m3/min (ft3/min) 13.01 (459) Cool m3/min (ft3/min) 32.2 (1135)
Outdoor
Airflow
Hi
Heat m
3
/min (ft3/min) 32.2 (1135)
Control Device Check Valve & Capillary Tube
Refrigerant Oil cm3 FV50S (320)
Refrigeration
Cycle
Refrigerant Type g (oz) R410A, 1.05k (37.1) Height(I/D / O/D) mm (inch) 290 (11-7/16) / 619 (24-3/8) Width (I/D / O/D) mm (inch) 870 (34-9/32) / 824 (32-15/32)
Dimension
Depth (I/D / O/D) mm (inch) 214 (8-7/16) / 299 (11-25/32)
Weight Net (I/D / O/D) kg (lb) 9 (20) / 33 (73)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 9.52 (3/8)
Standard length m (ft) 7.5 (24.6) Length range (min – max) m (ft) 3 (9.8) ~ 15 (49.2) I/D & O/D Height different m (ft) 15 (49.2)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Piping
Length for Additional Gas m (ft) 7.5 (24.6)
10
Inner Diameter mm 16
Drain Hose
Length mm 650
Fin Material Aluminium (Pre Coat)
Fin Type Slit Fin
Row x Stage x FPI 2 x 15 x 21
Indoor Heat
Exchanger
Size (W x H x L) mm 610 x 315 x 25.4
Fin Material Aluminium (Blue Coated)
Fin Type Corrugated Fin
Row x Stage x FPI 2 x 28 x 17
Outdoor
Heat
Exchanger
Size (W x H x L) mm 36.4 x 588 x 781.3:752.7
Material Polypropelene
Air Filter
Type One-touch
Power Supply Outdoor Power Supply
Power Supply Cord A Nil
Thermostat Electronic Contol
Protection Device Electronic Contol
DRY BULB WET BULB
Maximum 32 23
Cooling
Minimum 16 11
Maximum 30 -
Indoor
Operation
Range
Heating
Minimum 16 -
Maximum 46 26
Cooling
Minimum 5 4
Maximum 24 18
Outdoor
Operation
Range
Heating
Minimum -15 -16
1. Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5. Specifications are subjected to change without prior notice for further improvement.
11
Indoor CS-E12NKR
Model
Outdoor CU-E12NKR
Performance Test Condition AS
Phase, Hz Single, 50
Power Supply
V 230 240
Min. Mid. Max. Min. Mid. Max.
kW 0.90 3.50 4.00 0.90 3.50 4.00
BTU/h 3070 11900 13600 3070 11900 13600
Capacity
kcal/h 770 3010 3440 770 3010 3440
Running Current A - 3.9 - - 3.8 -
Input Power W 210 830 1.10k 210 830 1.10k
W/W 4.29 4.22 3.64 4.29 4.22 3.64
BTU/hW 14.62 14.34 12.36 14.62 14.34 12.36
EER
kcal/hW 3.67 3.63 3.13 3.67 3.63 3.13
Power Factor % - 93 - - 91 -
dB-A 41 / 26 / 21 41 / 26 / 21
Indoor Noise (H / L / QLo)
Power Level dB 57 / 42 / 37 57 / 42 / 37
dB-A 48 / - / - 48 / - / -
Cooling
Outdoor Noise (H / L / QLo)
Power Level dB 63 / - / - 63 / - / -
kW 0.80 4.90 5.40 0.80 4.90 5.40
BTU/h 2730 16700 18400 2730 16700 18400
Capacity
kcal/h 690 4210 4640 690 4210 4640
Running Current A - 5.6 - - 5.5 -
Input Power W 175 1.22k 1.42k 175 1.22k 1.42k
W/W 4.57 4.02 3.80 4.57 4.02 3.80
BTU/hW 15.60 13.69 12.96 15.60 13.69 12.96
COP
kcal/hW 3.94 3.45 3.27 3.94 3.45 3.27
Power Factor % - 95 - - 92 -
dB-A 44 / 29 / 26 44 / 29 / 26
Indoor Noise (H / L / QLo)
Power Level dB 60 / 45 / 42 60 / 45 / 42
dB-A 49 / - / - 49 / - / -
Heating
Outdoor Noise (H / L / QLo)
Power Level dB 64 / - / - 64 / - / -
Capacity kW 3.92
Input Power W 1.26k
H2
COP W/W 3.11
Capacity kW 6.70
Input Power W 1.89k
Powerful Heat
COP W/W 3.54
Max Current (A) / Max Input Power (W) 7.8 / 1.71k
Starting Current (A) 5.6
Type Hermetic Motor (Rotary)
Motor Type Brushless (6 poles)
Compressor
Output Power W 700
12
Type Cross-Flow Fan
Material ASG20K1 Motor Type Transistor (8-poles) Input Power W 47.3 - 47.3
Output Power W 40
Cool rpm 650
QLo
Heat rpm 770
Cool rpm 760
Lo
Heat rpm 870
Cool rpm 990
Me
Heat rpm 1090
Cool rpm 1220
Hi
Heat rpm 1320
Cool rpm 1320
Indoor Fan
Speed
SHi
Heat rpm 1360
Type Propeller Fan
Material PP Motor Type DC Motor (8-poles) Input Power W -
Output Power W 40
Cool rpm 870
Outdoor Fan
Speed Hi
Heat rpm 860
Moisture Removal L/h (Pt/h) 2.0 (4.2)
Cool m3/min (ft3/min) 5.81 (205)
QLo
Heat m
3
/min (ft3/min) 7.08 (250)
Cool m3/min (ft3/min) 7.03 (248)
Lo
Heat m
3
/min (ft3/min) 8.18 (289)
Cool m3/min (ft3/min) 9.56 (338)
Me
Heat m3/min (ft3/min) 10.58 (374)
Cool m3/min (ft3/min) 12.1 (425)
Hi
Heat m
3
/min (ft3/min) 13.1 (460)
Cool m3/min (ft3/min) 13.26 (468)
Indoor
Airflow
SHi
Heat m3/min (ft3/min) 13.53 (478)
Cool m3/min (ft3/min) 35.1 (1240)
Outdoor
Airflow
Hi
Heat m
3
/min (ft3/min) 35.1 (1240) Control Device Check Valve & Capillary Tube Refrigerant Oil cm3 FV50S (320)
Refrigeration
Cycle
Refrigerant Type g (oz) R410A, 1.10k (38.8) Height(I/D / O/D) mm (inch) 290 (11-7/16) / 619 (24-3/8) Width (I/D / O/D) mm (inch) 870 (34-9/32) / 824 (32-15/32)
Dimension
Depth (I/D / O/D) mm (inch) 214 (8-7/16) / 299 (11-25/32)
Weight Net (I/D / O/D) kg (lb) 9 (20) / 33 (73)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 12.70 (1/2)
Standard length m (ft) 7.5 (24.6) Length range (min – max) m (ft) 3 (9.8) ~ 15 (49.2) I/D & O/D Height different m (ft) 15 (49.2)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Piping
Length for Additional Gas m (ft) 7.5 (24.6)
13
Inner Diameter mm 16
Drain Hose
Length mm 650
Fin Material Aluminium (Pre Coat)
Fin Type Slit Fin
Row x Stage x FPI 2 x 15 x 21
Indoor Heat
Exchanger
Size (W x H x L) mm 610 x 315 x 25.4
Fin Material Aluminium (Blue Coated)
Fin Type Corrugated Fin
Row x Stage x FPI 2 x 28 x 17
Outdoor
Heat
Exchanger
Size (W x H x L) mm 36.4 x 588 x 781.3:752.7
Material Polypropelene
Air Filter
Type One-touch
Power Supply Outdoor Power Supply
Power Supply Cord A Nil
Thermostat Electronic Contol
Protection Device Electronic Contol
DRY BULB WET BULB
Maximum 32 23
Cooling
Minimum 16 11
Maximum 30 -
Indoor
Operation
Range
Heating
Minimum 16 -
Maximum 46 26
Cooling
Minimum 5 4
Maximum 24 18
Outdoor
Operation
Range
Heating
Minimum -15 -16
1. Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5. Specifications are subjected to change without prior notice for further improvement.
14
Indoor CS-E15NKR
Model
Outdoor CU-E15NKR
Performance Test Condition AS
Phase, Hz Single, 50
Power Supply
V 230 240
Min. Mid. Max. Min. Mid. Max.
kW 0.90 4.40 5.00 0.90 4.40 5.00
BTU/h 3070 15000 17100 3070 15000 17100
Capacity
kcal/h 770 3780 4300 770 3780 4300
Running Current A - 5.5 - - 5.3 -
Input Power W 215 1.20k 1.60k 215 1.20k 1.60k
W/W 4.19 3.67 3.13 4.19 3.67 3.13
BTU/hW 14.28 12.50 10.69 14.28 12.50 10.69
EER
kcal/hW 3.58 3.15 2.69 3.58 3.15 2.69
Power Factor % - 95 - - 94 -
dB-A 45 / 30 / 23 45 / 30 / 23
Indoor Noise (H / L / QLo)
Power Level dB 61 / 46 / 39 61 / 46 / 39
dB-A 46 / - / 41 46 / - / 41
Cooling
Outdoor Noise (H / L / QLo)
Power Level dB 61 / - / 56 61 / - / 56
kW 0.90 5.50 5.60 0.90 5.50 5.60
BTU/h 3070 18800 19100 3070 18800 19100
Capacity
kcal/h 770 4730 4820 770 4730 4820
Running Current A - 6.7 - - 6.5 -
Input Power W 245 1.47k 1.53k 245 1.47k 1.53k
W/W 3.67 3.74 3.66 3.67 3.74 3.66
BTU/hW 12.53 12.79 12.48 12.53 12.79 12.48
COP
kcal/hW 3.14 3.22 3.15 3.14 3.22 3.15
Power Factor % - 95 - - 94 -
dB-A 43 / 31 / 27 43 / 31 / 27
Indoor Noise (H / L / QLo)
Power Level dB 59 / 47 / 43 59 / 47 / 43
dB-A 46 / - / 41 46 / - / 41
Heating
Outdoor Noise (H / L / QLo)
Power Level dB 61 / - / 56 61 / - / 56
Capacity kW 4.05
Input Power W 1.35k
H2
COP W/W 3.00
Capacity kW 7.10
Input Power W 2.25k
Powerful Heat
COP W/W 3.16
Max Current (A) / Max Input Power (W) 10.2 / 2.32k
Starting Current (A) 6.7
Type Hermetic Motor (Rotary)
Motor Type Brushless (6 poles)
Compressor
Output Power W 900
15
Type Cross-Flow Fan
Material ASG20K1
Motor Type Transistor (8-poles)
Input Power W 94.8 - 94.8
Output Power W 40
Cool rpm 640
QLo
Heat rpm 790 Cool rpm 830
Lo
Heat rpm 900 Cool rpm 1090
Me
Heat rpm 1130 Cool rpm 1350
Hi
Heat rpm 1370 Cool rpm 1370
Indoor Fan
Speed
SHi
Heat rpm 1370
Type Propeller Fan
Material PP
Motor Type Induction (6-poles)
Input Power W -
Output Power W 40
Outdoor Fan
Speed Hi rpm 530 - 550
Moisture Removal L/h (Pt/h) 2.4 (5.1)
Cool m3/min (ft3/min) 5.69 (201)
QLo
Heat m
3
/min (ft3/min) 7.49 (264)
Cool m3/min (ft3/min) 7.78 (275)
Lo
Heat m3/min (ft3/min) 8.72 (308) Cool m3/min (ft3/min) 10.64 (376)
Me
Heat m3/min (ft3/min) 11.30 (399) Cool m3/min (ft3/min) 13.5 (475)
Hi
Heat m
3
/min (ft3/min) 14.0 (495)
Cool m3/min (ft3/min) 13.96 (493)
Indoor
Airflow
SHi
Heat m
3
/min (ft3/min) 14.00 (495)
Cool m3/min (ft3/min) 40.3 (1425) 41.9 (1480)
Outdoor
Airflow
Hi
Heat m
3
/min (ft3/min) 40.3 (1425) 41.9 (1480)
Control Device Expansion Valve
Refrigerant Oil cm3 FV50S (450)
Refrigeration
Cycle
Refrigerant Type g (oz) R410A, 1.12k (39.5) Height(I/D / O/D) mm (inch) 290 (11-7/16) / 795 (31-5/16) Width (I/D / O/D) mm (inch) 870 (34-9/32) / 875 (34-15/32)
Dimension
Depth (I/D / O/D) mm (inch) 214 (8-7/16) / 320 (12-5/8)
Weight Net (I/D / O/D) kg (lb) 9 (20) / 51 (112)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 12.70 (1/2)
Standard length m (ft) 7.5 (24.6) Length range (min – max) m (ft) 3 (9.8) ~ 15 (49.2) I/D & O/D Height different m (ft) 15 (49.2)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Piping
Length for Additional Gas m (ft) 7.5 (24.6)
16
Inner Diameter mm 16
Drain Hose
Length mm 650
Fin Material Aluminium (Pre Coat)
Fin Type Slit Fin
Row x Stage x FPI 2 x 15 x 21
Indoor Heat
Exchanger
Size (W x H x L) mm 610 x 315 x 25.4
Fin Material Aluminium (Blue Coated)
Fin Type Corrugated Fin
Row x Stage x FPI 2 x 36 x 19
Outdoor
Heat
Exchanger
Size (W x H x L) mm 36.4 x 756 x 620
Material Polypropelene
Air Filter
Type One-touch
Power Supply Outdoor Power Supply
Power Supply Cord A Nil
Thermostat Electronic Contol
Protection Device Electronic Contol
DRY BULB WET BULB
Maximum 32 23
Cooling
Minimum 16 11
Maximum 30 -
Indoor
Operation
Range
Heating
Minimum 16 -
Maximum 46 26
Cooling
Minimum 5 4
Maximum 24 18
Outdoor
Operation
Range
Heating
Minimum -15 -16
1. Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5. Specifications are subjected to change without prior notice for further improvement.
17
Indoor CS-E18NKR
Model
Outdoor CU-E18NKR
Performance Test Condition AS
Phase, Hz Single, 50
Power Supply
V 230 240
Min. Mid. Max. Min. Mid. Max.
kW 0.90 5.00 6.00 0.90 5.00 6.00
BTU/h 3070 17100 20500 3070 17100 20500
Capacity
kcal/h 770 4300 5160 770 4300 5160
Running Current A - 6.1 - - 5.9 -
Input Power W 230 1.30k 2.05k 230 1.30k 2.05k
W/W 3.91 3.85 2.93 3.91 3.85 2.93
BTU/hW 13.35 13.15 10.00 13.35 13.15 10.00
EER
kcal/hW 3.35 3.31 2.52 3.35 3.31 2.52
Power Factor % - 93 - - 92 -
dB-A 45 / 34 / 31 45 / 34 / 31
Indoor Noise (H / L / QLo)
Power Level dB 61 / 50 / 47 61 / 50 / 47
dB-A 47 / - / 42 47 / - / 42
Cooling
Outdoor Noise (H / L / QLo)
Power Level dB 61 / - / 56 61 / - / 56
kW 0.90 6.35 6.40 0.90 6.35 6.40
BTU/h 3070 21700 21800 3070 21700 21800
Capacity
kcal/h 770 5460 5500 770 5460 5500
Running Current A - 7.8 - - 7.6 -
Input Power W 260 1.69k 1.71k 260 1.69k 1.71k
W/W 3.46 3.76 3.74 3.46 3.76 3.74
BTU/hW 11.81 12.84 12.75 11.81 12.84 12.75
COP
kcal/hW 2.96 3.23 3.22 2.96 3.23 3.22
Power Factor % - 94 - - 93 -
dB-A 42 / 33 / 29 42 / 33 / 29
Indoor Noise (H / L / QLo)
Power Level dB 58 / 49 / 45 58 / 49 / 45
dB-A 47 / - / 42 47 / - / 42
Heating
Outdoor Noise (H / L / QLo)
Power Level dB 61 / - / 56 61 / - / 56
Capacity kW 4.6
Input Power W 1.51k
H2
COP W/W 3.05
Capacity kW 8.00
Input Power W 2.65k
Powerful Heat
COP W/W 3.02
Max Current (A) / Max Input Power (W) 11.9 / 2.65k
Starting Current (A) 7.8
Type Hermetic Motor (Rotary)
Motor Type Brushless (6 poles)
Compressor
Output Power W 900
18
Type Cross-Flow Fan
Material ASG30K1 Motor Type Transistor (8-poles) Input Power W 94.8 - 94.8
Output Power W 40
Cool rpm 870
QLo
Heat rpm 850
Cool rpm 950
Lo
Heat rpm 970
Cool rpm 1110
Me
Heat rpm 1130
Cool rpm 1280
Hi
Heat rpm 1300
Cool rpm 1400
Indoor Fan
Speed
SHi
Heat rpm 1420
Type Propeller Fan
Material PP Motor Type Induction (6-poles) Input Power W -
Output Power W 40
Outdoor Fan
Speed Hi rpm 580 - 600
Moisture Removal L/h (Pt/h) 2.8 (5.9)
Cool m3/min (ft3/min) 10.88 (384)
QLo
Heat m
3
/min (ft3/min) 11.11 (392)
Cool m3/min (ft3/min) 12.07 (426)
Lo
Heat m3/min (ft3/min) 12.68 (448)
Cool m3/min (ft3/min) 14.46 (511)
Me
Heat m3/min (ft3/min) 15.19 (536)
Cool m3/min (ft3/min) 17.0 (600)
Hi
Heat m
3
/min (ft3/min) 17.7 (625)
Cool m3/min (ft3/min) 18.92 (668)
Indoor
Airflow
SHi
Heat m
3
/min (ft3/min) 20.05 (708)
Cool m3/min (ft3/min) 46.7 (1650) 48.4 (1710)
Outdoor
Airflow
Hi
Heat m
3
/min (ft3/min) 46.7 (1650) 48.4 (1710) Control Device Expansion Valve Refrigerant Oil cm3 FV50S (450)
Refrigeration
Cycle
Refrigerant Type g (oz) R410A, 1.31k (46.2) Height(I/D / O/D) mm (inch) 290 (11-7/16) / 795 (31-5/16) Width (I/D / O/D) mm (inch) 1070 (42-5/32) / 875 (34-15/32)
Dimension
Depth (I/D / O/D) mm (inch) 240 (9-15/32) / 320 (12-5/8)
Weight Net (I/D / O/D) kg (lb) 12 (26) / 52 (115)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 12.70 (1/2)
Standard length m (ft) 5.0 (16.4) Length range (min – max) m (ft) 3 (9.8) ~ 20 (65.6) I/D & O/D Height different m (ft) 15 (49.2)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Piping
Length for Additional Gas m (ft) 10 (32.8)
19
Inner Diameter mm 16
Drain Hose
Length mm 650
Fin Material Aluminium (Pre Coat)
Fin Type Slit Fin
Row x Stage x FPI 2 x 15 x 19
Indoor Heat
Exchanger
Size (W x H x L) mm 810 x 315 x 25.4
Fin Material Aluminium (Blue Coated)
Fin Type Corrugated Fin
Row x Stage x FPI 2 x 36 x 18
Outdoor
Heat
Exchanger
Size (W x H x L) mm 36.4 x 756 x 839:810.6
Material Polypropelene
Air Filter
Type One-touch
Power Supply Outdoor Power Supply
Power Supply Cord A Nil
Thermostat Electronic Contol
Protection Device Electronic Contol
DRY BULB WET BULB
Maximum 32 23
Cooling
Minimum 16 11
Maximum 30 -
Indoor
Operation
Range
Heating
Minimum 16 -
Maximum 46 26
Cooling
Minimum 5 4
Maximum 24 18
Outdoor
Operation
Range
Heating
Minimum -15 -16
1. Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5. Specifications are subjected to change without prior notice for further improvement.
20
Indoor CS-E21NKR
Model
Outdoor CU-E21NKR
Performance Test Condition AS
Phase, Hz Single, 50
Power Supply
V 230 240
Min. Mid. Max. Min. Mid. Max.
kW 1.70 6.30 7.10 1.70 6.30 7.10
BTU/h 5800 21500 24200 5800 21500 24200
Capacity
kcal/h 1460 5420 6110 1460 5420 6110
Running Current A - 8.3 - - 8.1 -
Input Power W 440 1.80k 2.20k 440 1.80k 2.20k
W/W 3.86 3.50 3.23 3.86 3.50 3.23
BTU/hW 13.18 11.94 11.00 13.18 11.94 11.00
EER
kcal/hW 3.32 3.01 2.78 3.32 3.01 2.78
Power Factor % - 94 - - 93 -
dB-A 45 / 36 / 33 45 / 36 / 33
Indoor Noise (H / L / QLo)
Power Level dB 61 / 52 / 49 61 / 52 / 49
dB-A 52 / - / 47 52 / - / 47
Cooling
Outdoor Noise (H / L / QLo)
Power Level dB 66 / - / 61 66 / - / 61
kW 1.70 7.20 7.70 1.70 7.20 7.70
BTU/h 5800 24600 26300 5800 24600 26300
Capacity
kcal/h 1460 6190 6620 1460 6190 6620
Running Current A - 8.9 - - 8.6 -
Input Power W 400 1.98k 2.17k 400 1.98k 2.17k
W/W 4.25 3.64 3.55 4.25 3.64 3.55
BTU/hW 14.50 12.42 12.12 14.50 12.42 12.12
COP
kcal/hW 3.65 3.13 3.05 3.65 3.13 3.05
Power Factor % - 97 - - 96 -
dB-A 45 / 35 / 32 45 / 35 / 32
Indoor Noise (H / L / QLo)
Power Level dB 61 / 51 / 48 61 / 51 / 48
dB-A 52 / - / 47 52 / - / 47
Heating
Outdoor Noise (H / L / QLo)
Power Level dB 66 / - / 61 66 / - / 61
Capacity kW 5.6
Input Power W 1.92k
H2
COP W/W 2.92
Capacity kW 8.50
Input Power W 2.50k
Powerful Heat
COP W/W 3.40
Max Current (A) / Max Input Power (W) 12.2 / 2.74k
Starting Current (A) 8.9
Type Hermetic Motor (Rotary)
Motor Type Brushless (4 poles)
Compressor
Output Power W 1.70k
21
Type Cross-Flow Fan
Material ASG30K1
Motor Type Transistor (8-poles)
Input Power W 94.8 - 94.8
Output Power W 40
Cool rpm 860
QLo
Heat rpm 910 Cool rpm 960
Lo
Heat rpm 1000 Cool rpm 1150
Me
Heat rpm 1190 Cool rpm 1350
Hi
Heat rpm 1390 Cool rpm 1400
Indoor Fan
Speed
SHi
Heat rpm 1490
Type Propeller Fan
Material PP
Motor Type Induction (6-poles)
Input Power W -
Output Power W 80
Outdoor Fan
Speed Hi rpm 690 - 720
Moisture Removal L/h (Pt/h) 3.5 (7.4)
Cool m3/min (ft3/min) 10.07 (356)
QLo
Heat m
3
/min (ft3/min) 10.11 (357)
Cool m3/min (ft3/min) 11.46 (405)
Lo
Heat m3/min (ft3/min) 11.29 (399) Cool m3/min (ft3/min) 14.11 (498)
Me
Heat m3/min (ft3/min) 13.78 (487) Cool m3/min (ft3/min) 16.9 (595)
Hi
Heat m
3
/min (ft3/min) 16.4 (580)
Cool m3/min (ft3/min) 17.60 (621)
Indoor
Airflow
SHi
Heat m
3
/min (ft3/min) 17.71 (625)
Cool m3/min (ft3/min) 54.5 (1925) 56.5 (1995)
Outdoor
Airflow
Hi
Heat m
3
/min (ft3/min) 54.5 (1925) 56.5 (1995)
Control Device Expansion Valve
Refrigerant Oil cm3 FV50S (800)
Refrigeration
Cycle
Refrigerant Type g (oz) R410A, 1.60k (56.5) Height(I/D / O/D) mm (inch) 290 (11-7/16) / 795 (31-5/16) Width (I/D / O/D) mm (inch) 1070 (42-5/32) / 875 (34-15/32)
Dimension
Depth (I/D / O/D) mm (inch) 240 (9-15/32) / 320 (12-5/8)
Weight Net (I/D / O/D) kg (lb) 12 (26) / 59 (130)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 12.70 (1/2)
Standard length m (ft) 5.0 (16.4) Length range (min – max) m (ft) 3 (9.8) ~ 20 (65.6) I/D & O/D Height different m (ft) 15 (49.2)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Piping
Length for Additional Gas m (ft) 10 (32.8)
22
Inner Diameter mm 16
Drain Hose
Length mm 650
Fin Material Aluminium (Pre Coat)
Fin Type Slit Fin
Row x Stage x FPI 2 x 15 x 21
Indoor Heat
Exchanger
Size (W x H x L) mm 810 x 315 x 25.4
Fin Material Aluminium (Blue Coated)
Fin Type Corrugated Fin
Row x Stage x FPI 2 x 30 x 19
Outdoor
Heat
Exchanger
Size (W x H x L) mm 38.1 x 762 x 895.8:865.8
Material Polypropelene
Air Filter
Type One-touch
Power Supply Outdoor Power Supply
Power Supply Cord A Nil
Thermostat Electronic Contol
Protection Device Electronic Contol
DRY BULB WET BULB
Maximum 32 23
Cooling
Minimum 16 11
Maximum 30 -
Indoor
Operation
Range
Heating
Minimum 16 -
Maximum 46 26
Cooling
Minimum 5 4
Maximum 24 18
Outdoor
Operation
Range
Heating
Minimum -15 -16
1. Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5. Specifications are subjected to change without prior notice for further improvement.
23
Indoor CS-E24NKR
Model
Outdoor CU-E24NKR
Performance Test Condition AS
Phase, Hz Single, 50
Power Supply
V 230 240
Min. Mid. Max. Min. Mid. Max.
kW 1.70 7.10 8.10 1.70 7.10 8.10
BTU/h 5800 24200 27600 5800 24200 27600
Capacity
kcal/h 1460 6110 6970 1460 6110 6970
Running Current A - 9.7 - - 9.4 -
Input Power W 430 2.11k 2.48k 430 2.11k 2.48k
W/W 3.95 3.36 3.27 3.95 3.36 3.27
BTU/hW 13.49 11.47 11.13 13.49 11.47 11.13
EER
kcal/hW 3.40 2.90 2.81 3.40 2.90 2.81
Power Factor % - 95 - - 94 -
dB-A 47 / 37 / 34 47 / 37 / 34
Indoor Noise (H / L / QLo)
Power Level dB 63 / 53 / 50 63 / 53 / 50
dB-A 53 / - / 48 53 / - / 48
Cooling
Outdoor Noise (H / L / QLo)
Power Level dB 67 / - / 62 67 / - / 62
kW 1.70 8.00 8.56 1.70 8.00 8.56
BTU/h 5800 27300 29200 5800 27300 29200
Capacity
kcal/h 1460 6880 7360 1460 6880 7360
Running Current A - 10.2 - - 9.9 -
Input Power W 380 2.21k 2.37k 380 2.21k 2.37k
W/W 4.47 3.62 3.61 4.47 3.62 3.61
BTU/hW 15.26 12.35 12.32 15.26 12.35 12.32
COP
kcal/hW 3.84 3.11 3.11 3.84 3.11 3.11
Power Factor % - 94 - - 93 -
dB-A 47 / 37 / 34 47 / 37 / 34
Indoor Noise (H / L / QLo)
Power Level dB 63 / 53 / 50 63 / 53 / 50
dB-A 53 / - / 48 53 / - / 48
Heating
Outdoor Noise (H / L / QLo)
Power Level dB 67 / - / 62 67 / - / 62
Capacity kW 6.2
Input Power kW 2.10
H2
COP W/W 2.95
Capacity kW 9.90
Input Power kW 3.00
Powerful Heat
COP W/W 3.30
Max Current (A) / Max Input Power (W) 14.6 / 3.20k
Starting Current (A) 10.2
Type Hermetic Motor (Rotary)
Motor Type Brushless (4 poles)
Compressor
Output Power W 1.70k
24
Type Cross-Flow Fan
Material ASG30K1 Motor Type Transistor (8-poles) Input Power W 94.8 - 94.8
Output Power W 40
Cool rpm 890
QLo
Heat rpm 960
Cool rpm 990
Lo
Heat rpm 1060
Cool rpm 1230
Me
Heat rpm 1250
Cool rpm 1470
Hi
Heat rpm 1440
Cool rpm 1530
Indoor Fan
Speed
SHi
Heat rpm 1540
Type Propeller Fan
Material PP Motor Type DC Motor (8-poles) Input Power W -
Output Power W 60
Cool rpm 700
Outdoor Fan
Speed Hi
Heat rpm 700
Moisture Removal L/h (Pt/h) 4.1 (8.7)
Cool m3/min (ft3/min) 11.07 (391)
QLo
Heat m
3
/min (ft3/min) 12.42 (439)
Cool m3/min (ft3/min) 12.54 (443)
Lo
Heat m
3
/min (ft3/min) 13.98 (494)
Cool m3/min (ft3/min) 16.07 (567)
Me
Heat m3/min (ft3/min) 16.94 (598)
Cool m3/min (ft3/min) 19.6 (690)
Hi
Heat m
3
/min (ft3/min) 20.3 (715)
Cool m3/min (ft3/min) 20.40 (720)
Indoor
Airflow
SHi
Heat m3/min (ft3/min) 20.82 (735)
Cool m3/min (ft3/min) 56.5 (1995)
Outdoor
Airflow
Hi
Heat m
3
/min (ft3/min) 56.5 (1995) Control Device Check Valve & Capillary Tube Refrigerant Oil cm3 FV50S (800)
Refrigeration
Cycle
Refrigerant Type g (oz) R410A, 1.70k (60.0) Height(I/D / O/D) mm (inch) 290 (11-7/16) / 795 (31-5/16) Width (I/D / O/D) mm (inch) 1070 (42-5/32) / 875 (34-15/32)
Dimension
Depth (I/D / O/D) mm (inch) 240 (9-15/32) / 320 (12-5/8)
Weight Net (I/D / O/D) kg (lb) 12 (26) / 60 (132)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 15.88 (5/8)
Standard length m (ft) 5.0 (16.4) Length range (min – max) m (ft) 3 (9.8) ~ 30 (98.4) I/D & O/D Height different m (ft) 20 (65.6)
Additional Gas Amount g/m (oz/ft) 30 (0.3)
Piping
Length for Additional Gas m (ft) 10 (32.8)
25
Inner Diameter mm 16
Drain Hose
Length mm 650
Fin Material Aluminium (Pre Coat)
Fin Type Slit Fin
Row x Stage x FPI 2 x 15 x 21
Indoor Heat
Exchanger
Size (W x H x L) mm 25.4 x 315 x 810
Fin Material Aluminium (Blue Coated)
Fin Type Corrugated Fin
Row x Stage x FPI 2 x 30 x 19
Outdoor
Heat
Exchanger
Size (W x H x L) mm 38.1 x 762 x 895.8:865.8
Material Polypropelene
Air Filter
Type One-touch
Power Supply Outdoor Power Supply
Power Supply Cord A Nil
Thermostat Electronic Contol
Protection Device Electronic Contol
DRY BULB WET BULB
Maximum 32 23
Cooling
Minimum 16 11
Maximum 30 -
Indoor
Operation
Range
Heating
Minimum 16 -
Maximum 46 26
Cooling
Minimum 5 4
Maximum 24 18
Outdoor
Operation
Range
Heating
Minimum -15 -16
1. Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5. Specifications are subjected to change without prior notice for further improvement.
26
Indoor CS-E28NKR
Model
Outdoor CS-E28NKR
Performance Test Condition AS
Phase, Hz Single, 50
Power Supply
V 230 240
Min. Mid. Max. Min. Mid. Max.
kW 2.30 8.00 8.60 2.30 8.00 8.60
BTU/h 7840 27300 29300 7840 27300 29300
Capacity
kcal/h 1980 6880 7400 1980 6880 7400
Running Current A - 11.2 - - 10.9 -
Input Power W 460 2.39k 2.70k 460 2.39k 2.70k
W/W 5.00 3.35 3.19 5.00 3.35 3.19
BTU/hW 17.04 11.42 10.85 17.04 11.42 10.85
EER
kcal/hW 4.30 2.88 2.74 4.30 2.88 2.74
Power Factor % - 93 - - 91 -
dB-A 49 / 38 / 35 49 / 38 / 35
Indoor Noise (H / L / QLo)
Power Level dB 65 / 54 / 51 65 / 54 / 51
dB-A 53 / - / 48 53 / - / 48
Cooling
Outdoor Noise (H / L / QLo)
Power Level dB 71 / - / 66 71 / - / 66
kW 2.20 9.00 10.21 2.20 9.00 10.21
BTU/h 7500 30700 34800 7500 30700 34800
Capacity
kcal/h 1890 7740 8780 1890 7740 8780
Running Current A - 12.2 - - 11.9 -
Input Power W 500 2.63k 2.99k 500 2.63k 2.99k
W/W 4.40 3.42 3.41 4.40 3.42 3.41
BTU/hW 15.00 11.67 11.64 15.00 11.67 11.64
COP
kcal/hW 3.78 2.94 2.94 3.78 2.94 2.94
Power Factor % - 94 - - 92 -
dB-A 48 / 38 / 35 48 / 38 / 35
Indoor Noise (H / L / QLo)
Power Level dB 64 / 54 / 51 64 / 54 / 51
dB-A 53 / - / 48 53 / - / 48
Heating
Outdoor Noise (H / L / QLo)
Power Level dB 71 / - / 66 71 / - / 66
Capacity kW 7.4
Input Power kW 2.65
H2
COP W/W 2.79
Capacity kW 11.00
Input Power kW 3.30
Powerful Heat
COP W/W 3.33
Max Current (A) / Max Input Power (W) 15.9 / 3.79k
Starting Current (A) 12.2
Type Hermetic Motor (Rotary)
Motor Type Brushless (4 poles)
Compressor
Output Power W 1.70k
27
Type Cross-Flow Fan
Material ASG30K1
Motor Type Transistor (8-poles)
Input Power W 94.8 - 94.8
Output Power W 40
Cool rpm 970
QLo
Heat rpm 1000 Cool rpm 1070
Lo
Heat rpm 1100 Cool rpm 1300
Me
Heat rpm 1330 Cool rpm 1530
Hi
Heat rpm 1560 Cool rpm 1570
Indoor Fan
Speed
SHi
Heat rpm 1570
Type Propeller Fan
Material PP
Motor Type DC Motor (8-poles)
Input Power W -
Output Power W 44 x 2
Cool rpm 610 - 650
Outdoor Fan
Speed Hi
Heat rpm 690 - 730
Moisture Removal L/h (Pt/h) 4.7 (9.9)
Cool m3/min (ft3/min) 12.20 (431)
QLo
Heat m
3
/min (ft3/min) 12.67 (447)
Cool m3/min (ft3/min) 13.66 (482)
Lo
Heat m
3
/min (ft3/min) 14.14 (499)
Cool m3/min (ft3/min) 17.03 (601)
Me
Heat m3/min (ft3/min) 18.01 (636) Cool m3/min (ft3/min) 20.4 (720)
Hi
Heat m
3
/min (ft3/min) 20.9 (740)
Cool m3/min (ft3/min) 20.99 (741)
Indoor
Airflow
SHi
Heat m3/min (ft3/min) 21.55 (761) Cool m3/min (ft3/min) 75.0 (2650)
Outdoor
Airflow
Hi
Heat m
3
/min (ft3/min) 75.0 (2650)
Control Device Check Valve & Capillary Tube
Refrigerant Oil cm3 FV50S (800)
Refrigeration
Cycle
Refrigerant Type g (oz) R410A, 2.15k (75.9) Height(I/D / O/D) mm (inch) 290 (11-7/16) / 1170 (46-3/32) Width (I/D / O/D) mm (inch) 1070 (42-5/32) / 900 (35-7/16)
Dimension
Depth (I/D / O/D) mm (inch) 240 (9-15/32) / 320 (12-5/8)
Weight Net (I/D / O/D) kg (lb) 12 (26) / 74 (163)
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 15.88 (5/8)
Standard length m (ft) 5.0 (16.4) Length range (min – max) m (ft) 3 (9.8) ~ 30 (98.4) I/D & O/D Height different m (ft) 20 (65.6)
Additional Gas Amount g/m (oz/ft) 30 (0.3)
Piping
Length for Additional Gas m (ft) 10 (32.8)
28
Inner Diameter mm 16
Drain Hose
Length mm 650
Fin Material Aluminium (Pre Coat)
Fin Type Slit Fin
Row x Stage x FPI 2 x 15 x 21
Indoor Heat
Exchanger
Size (W x H x L) mm 25.4 x 315 x 810
Fin Material Aluminium (Blue Coated)
Fin Type Corrugated Fin
Row x Stage x FPI 2 x 44 x 19
Outdoor
Heat
Exchanger
Size (W x H x L) mm 38.1 x 1117.6 x 863.8:833.8
Material Polypropelene
Air Filter
Type One-touch
Power Supply Outdoor Power Supply
Power Supply Cord A Nil
Thermostat Electronic Contol
Protection Device Electronic Contol
DRY BULB WET BULB
Maximum 32 23
Cooling
Minimum 16 11
Maximum 30 -
Indoor
Operation
Range
Heating
Minimum 16 -
Maximum 46 26
Cooling
Minimum 16 11
Maximum 24 18
Outdoor
Operation
Range
Heating
Minimum -15 -16
1. Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5. Specifications are subjected to change without prior notice for further improvement.
29
3. Features
Inverter Technology
o Wider output power range o Energy saving o Quick Cooling o Quick Heating o More precise temperature control
E-ion Air Purifying System with Patrol Sensor
o Active e-ions are released to catch dust particles and bring them back the large positively charged filter
Environment Protection
o Non-ozone depletion substances refrigerant (R410A)
Long Installation Piping
o Long piping up to 15 meters (0.75 ~ 1.75HP), 20 meters (2.0 ~ 2.25HP) and 30 meters (2.5 ~ 3.0HP) du ring
single split connection only
Easy to use remote control Quality Improvement
o Random auto restart after power failure for safety restart operation o Gas leakage protection o Prevent compressor reverse cycle o Inner protector to protect compressor o Noise prevention during soft dry operation
Operation Improvement
o Quiet mode to reduce the indoor unit operating sound o Powerful mode to reach the desired room temperature quickly o 24-hour timer setting
Serviceability Improvement
o Breakdown Self Diagnosis function
30
4. Location of Controls and Components
4.1 Indoor Unit
4.2 Outdoor Unit
4.3 Remote Control
Loading...
+ 175 hidden pages