Panasonic CU-C24BBP5, CU-C28BBP5, CU-A24BBP5, CS-A24BB4P, CU-A28BBP5 Service Manual

...
ORDER NO. MAC0112071C0
AIR CONDITIONER
CASSETTE TYPE
Indoor Model / Outdoor Model
(Cooling / Heat Pump) CS-A24BB4P / (CU-C24BBP5 / CU-A24BBP5) CS-A28BB4P / (CU-C28BBP5 / CU-A28BBP5) CS-A28BB4P / (CU-C28BBP8 / CU-A28BBP8) CS-A28BB4P / (CU-C28BBP6) CS-A34BB4P / (CU-C34BBP5 / CU-A34BBP5) CS-A34BB4P / (CU-C34BBP8 / CU-A34BBP8) CS-A34BB4P / (CU-C34BBP7) CS-A43BB4P / (CU-C43BBP8 / CU-A43BBP8) CS-A43BB4P / (CU-C43BBP7) CS-A50BB4P / (CU-C50BBP8 / CU-A50BBP8) CS-A50BB4P / (CU-C50BBP7)
CONTENTS
Page Page
1 SERVICE INFORMATION 3 2 FEATURES 4 3 SPECIFICATION (HEAT PUMP TYPE ) 8 4 SPECIFICATION (COOLING ONLY TYPE ) 15 5 TECHNICAL DRAWING 26 6 CIRCUIT DIAGRAM 32 7 OPERATING INSTRUCTION 48 8 REFRIGERATION CYCLE 50 9 OPERATION RANGE 52
10 PIPE LENGTH 53 11 OPERATING CHARACTERISTIC 55 12 FAN PERFORMANCE 56 13 SAFETY DEVICE 58 14 COMPONENT SPECIFICATION 59 15 CAPACITY AND POWER CONSUMPTION 60 16 DISCHARGE AND SUCTION PRESSURE 66 17 POSITION OF THE CENTER GRAVITY 67
© 2001 Matsushita Air-Conditioning Corp. Sdn. Bhd. (183914D). All rights reserved. Unauthorized copying and distribution is a violation of law.
18 REACHING DISTANCE 68 19 SOUND DATA 70 20 TWIN AND TRIPLE 75 21 WIRING MISTAKE PREVENTION 80 22 TEST OPERATION AND SELF DIAGNOSIS 81 23 SETTING OF SAVE ENERGY AND THERMISTOR SWITCH 85 24 GROUP CONTROL 86 25 TROUBLESHOOTING 87 26 EMERGENCY OPERATION 92
27 CONTROL 93 28 WIRED REMOTE CONTROL INSTALLATION MANUAL 104 29 WIRELESS REMOTE CONTROL INSTALLATION MANUAL 109 30 INSTALLATION (INDOOR UNIT) 116 31 INSTALLATION (OUTDOOR UNIT) 125 32 REPLACEMENT PARTS 134 33 HEATING CAPACITY PERFORMANCE DATA 151 34 COOLING CAPACITY PERFORMANCE DATA 152
2
CASSETTE TYPE
1 SERVICE INFORMATION
Notice of Address setting for NEW Cassette / NEW Outdoor Unit.
The new Cassette / new Outdoor models are possible to have address setting for twin / triple control or group control automatically when main power supply is switched on.
(Manual address setting is also possible by using DSW1 switch on the indoor unit P.C. board.) However, this address setting is only possible when proper wiring connection is made and indoor unit must be of original unit.
1.1. Example of trouble during test operation
If the below phenomenon is found during test operation, wrong address setting is possible. Therefore, please inspect the address setting.
1. LCD display of the wired remote control is not illuminated although the main power supply switch is ‘on’.
2. LCD display had indicated as normal illumination when power supply switch is ‘on’, however outdoor unit cannot be operated. (But, it is necessary to take 3 to 5 minutes for outdoor unit to start from the timing of remote control OFF/ON button is ‘on’.) (For normal operation, the outdoor unit will only start its operation after 3 to 5 minutes upon pressing the OFF/ON button.)
3. P.C. board had memorized wrong setting information. a. If main power supply is switched on with the wrong connection. b. When changing the connection or combination of units due to re-installation etc.
• • When changing the system from twin to triple (triple to twin).
• • When changing the system from group control to normal one to one system.
• • When making the replacement of units of master and slave etc.
1.2. Caution during test operation
Do not touch the remote control button and do not change any wirings for one minute when the main power supply switch is ‘on’. (Because the unit is having automatic address setting during the first one minute.)
1.3. Caution during automatic address setting
When the main power supply switch is ‘on’, the P.C. board will automatically memorize the connecting system. Consequently, when initial power supply is ‘on’, there mustn’t be any interchanging of units even of the same type and same
capacity unit. Therefore, connection of the unit to another system is prohibited.
3
2 FEATURES
2.1. Variety of excellent features
• • Compact design
Compact design 240 mm height, 840 mm width and 840 mm depth. (3 HP unit body)
• • Automatic restart function
When the electric power resumes after a power failure, the unit will automatically restarts the operation in the pre­failure mode.
• • Auto fan mode (indoor unit)
Auto fan mode is added besides HI, ME and LO. It automatically adjusts the fan speed according to the indoor temperature.
• • Dry mode function
Dry mode can make a comfortable indoor environment during wet season.
• • Quiet operation
The sound level is 41dB (A) for 28BB model during High
Fan speed and suitable for offices, shops, homes etc, when quiet operation is essential.
• • Auto Swing Louvre
The air flow angle can be changed automatically (or manually) to an angle between 10° to 70° using the remote control.
• • Low ambient cooling operation
Cooling operation is possible at outdoor temperature of
-5°C.
• • Automatic changeover function (heat pump models)
The unit automatically switches between cooling and heating in accordance with operating load in order to maintain a comfortable indoor temperature.
• • Hot start system (heat pump models)
• • Pipes and drainage
Built-in upward draining mechanism.
4
2.2. Low-noise outdoor units
CASSETTE TYPE
2.2.1. Product features
• • Low-noise design improves comfort in surrounding areas
1. The noise-suppressing winglet fan is a result of new
research into vane design theory. The unique curved shape suppresses the generation of vortexes, thus reducing air flow noise.
2. The adoption of double-orifice rings reduces air
passage resistance.
3. Strengthening of the noise insulation materials in the
compressor and the sealing-in of mechanical noise allows vibration noise to be greatly enclosed and suppressed.
4. The heat exchanger has an L-shaped design to allow air
to flow more smoothly.
5. Noise is automatically reduced further during night-time
operation with lower outdoor air temperatures.
2.3. Greatly improved workability increases system renewal capability
• • Pipes that are one size larger can also be connected for
renewal.
− − If renewing the system, existing refrigerant pipes can be utilized so that only the indoor and outdoor units need to be replaced.
− − For example, liquid and gas pipes from 10 years ago can be connected to current pipes with the same size or one size larger. Effective utilization of materials reduces working time and trouble. (Adaptor sockets are not supplied.)
5
• • Additional refrigerant charging unnecessary for 30 m
− − All models do not require any additional charging of
refrigerant for 30 m of pipe length. This makes installation much easier.
• • Drain water dripping-prevention structure
− − The base of the outdoor unit is provided with a single
drain hole in order to prevent drain water from leaking out of the unit. By connecting a drain elbow and a discharge pipe, water leakages can be prevented even when the unit is installed to a wall.
• • Save space design allows units to be installed side-by-
side continuously
− − Servicing after installation can be carried out by removing the front covers.
• • Long pipe design for refrigerant pipes
− − Maximum piping length of 50m for all models.
• • Internal pipe connection
− − Pipes are connected inside the units (inside the side
covers), making the final appearance more attractive.
− − Pipes can be diverted outward in any of four directions (forward, right, down, rear).
− − Small liquid pipe diameters of 9.52mm for 43BB and 50BB models, making installation work much easier.
• • Centralized draining method
− − Even when multiple outdoor units are installed to a wall,
the drain outlets can be concentrated into a single drain pipe. This makes installation easier and also improves appearance.
2.4. A brand-new control method using the latest in technology
• • Easier power supply wiring connection
Power supply wiring and other wiring tasks can be carried out more easily.
− − Twin non-polar wires used to connect indoor and outdoor units.
− − Adoption of connection error prevention circuits for drive wires and signal wires. If a connection error is made, the relay does not operate and current does not flow to the circuit boards.
• • Twin and Triple operation
− − Simultaneous air conditioning of wide spaces and
corners is possible. Indoor units of different horsepowers can even be used in combination.
− − Master unit and slave-units can be set automatically in twin and triple systems. No address setting is necessary.
− − Multiple indoor units can be operated simultaneously with a single remote control. Note that individual operation is not possible.
• • Separate indoor/outdoor unit power supplies
The power supply can be connected to (1) just the outdoor units, or (2) to both the indoor and outdoor units.
• • Easy test operation
Test operation can be carried out for both indoor and outdoor units.
• • Automatic setting initialization function (Remote control and Indoor unit) In accordance with the indoor and outdoor units connected and the connection methods, conditions such as the connection configuration (twin or triple format) and remote­control functions such as automatic louvre operation and cooling or heating mode are automatically detected and set instantly.
6
CASSETTE TYPE
2.5. Wired Remote Control
• • The new design includes an easily-visible red pilot lamp. The power can be turned on and off at a single touch, without opening the cover.
• • Has a built-in thermistor, allowing indoor temperature detection in accordance with indoor conditions by switching with main unit thermistor.
• • Twin non-polar wires make installation work easy. (10 m cable supplied as accessory.)
2.6. Wireless Remote Control
• • New design with compact size. (Operation range within approximately 8 m.)
• • Built-in timer with ON/OFF timer setting (within 24 hours)
Wired Wireless
Heat Pump CZ-RD51P CZ-RL51P
Cooling CZ-RD51P CZ-RL01P
2.7. Group Control Equipment
NOTE: Both of the above remote control is packed separately from the indoor unit.
7
3 SPECIFICATION (HEAT PUMP TYPE )
3.1. CS-A24BB4P / CU-A24BBP5
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A24BB4P CU-A24BBP5
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL51P (Wireless)
Cooling Capacity kW 6.3
BTU/h 21,500
Heating Capacity kW 7.1
BTU/h 24,200 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 17 Me 15 Lo 14 Hi 43 Medium and Low Speed cfm 600 530 494 1518 Outside Dimension (H x W x D) mm 240 x 840 x 840 900 x 900 x 320
inch 9-7/16 x 33-1/24 x 33-1/24 35-7/1 6 x 35-7/16 x 12-19/32
Net Weight kg 26 81
lbs 57 179
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Rotary), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-1
Air-heat Exchanger Slit-fin type Louvre-fin type Refrigerant Control Cool Capillary tube -
Refrigerant Oil (Charged) litre - MS32 (1.3) Refrigerant (Charged) kg - (2.5)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level Cool dB (A) Hi 42 Me 40 Lo 38 Hi 50
Refrigerant Gas mm (inch) O.D Ø 15.88 (5/8) Flared Type
Liquid mm (inch) O.D Ø 6.35 (1/4) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole single phase induction motor
Input kW - Cool/Heat 2.31/2.30 Rated Output kW - 1.9
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.08 0.11 Rated Output kW 0.03 0.05
Heat - Capillary tube
lbs (5.5) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High and heating pressure switch, Current transformer
Heat Hi 42 Me 40 Lo 38 Hi 51
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F D.B.), 6°C W.B. (42.8°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL CS-A24BB4P, CU-A24BBP5
Condition by JIS B 8615 Volts V 220 230 240 Phase Single Single Single Power Consumption kW Cool 2.50 2.50 2.50
Heat 2.49 2.49 2.49
Running Current A Cool 11.5 11.1 10.7
Heat 11.4 11.0 10.7 Starting Current A 49 51 52 Power Factor % Cool 99 98 97
Heat 99 98 97 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 1~220V, 230V, 240V 50Hz
8
CASSETTE TYPE
3.2. CS-A28BB4P / CU-A28BBP5
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A28BB4P CU-A28BBP5
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL51P (Wireless)
Cooling Capacity kW 7.1
BTU/h 24,200
Heating Capacity kW 8.0
BTU/h 27,300 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 20 Me 18 Lo 16 Hi 43 Medium and Low Speed cfm 706 635 565 1518 Outside Dimension (H x W x D) mm 240 x 840 x 840 900 x 900 x 320
inch 9-7/16 x 33-1/24 x 33-1/24 35-7/16 x 35-7/16 x 12-19/32
Net Weight kg 26 82
lbs 57 181
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Rotary), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-1
Air-heat Exchanger Slit-fin type Louvre-fin type Refrigerant Control Cool Capillary tube -
Refrigerant Oil (Charged) litre - MS32 (1.3) Refrigerant (Charged) kg - (3.8)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level Cool dB (A) Hi 44 Me 42 Lo 40 Hi 50
Refrigerant Gas mm (inch) O.D Ø 15.88 (5/8) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole single phase induction motor
Input kW - Cool/Heat 2.49/2.41 Rated Output kW - 2.0
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.09 0.11 Rated Output kW 0.04 0.05
Heat - Capillary tube
lbs (8.4) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High and heating pressure switch, Current transformer
Heat Hi 44 Me 42 Lo 40 Hi 53
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F D.B.), 6°C W.B. (42.8°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL CS-A28BB4P, CU-A28BBP5
Condition by JIS B 8615 Volts V 220 230 240 Phase Single Single Single Power Consumption kW Cool 2.69 2.69 2.69
Heat 2.61 2.61 2.61
Running Current A Cool 12.3 12.0 11.7
Heat 12.0 11.7 11.4 Starting Current A 50 52 54 Power Factor % Cool 99 98 96
Heat 99 97 95 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 1~220V, 230V, 240V 50Hz
9
3.3. CS-A28BB4P / CU-A28BBP8
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A28BB4P CU-A28BBP8
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL51P (Wireless)
Cooling Capacity kW 7.1
BTU/h 24,200
Heating Capacity kW 8.0
BTU/h 27,300 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 20 Me 18 Lo 16 Hi 43 Medium and Low Speed cfm 706 635 565 1518 Outside Dimension (H x W x D) mm 240 x 840 x 840 900 x 900 x 320
inch 9-7/16 x 33-1/24 x 33-1/24 35-7/1 6 x 35-7/16 x 12-19/32
Net Weight kg 26 82
lbs 57 181
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Rotary), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-1
Air-heat Exchanger Slit-fin type Louvre-fin type Refrigerant Control Cool Capillary tube -
Refrigerant Oil (Charged) litre - MS32 (1.3) Refrigerant (Charged) kg - (3.8)
Running Adjustment
Safety Devices Heat thermostat for compressor, Internal thermostat for fan motor,
Noise Level Cool dB (A) Hi 39 Me 37 Lo 35 Hi 50
Refrigerant Gas mm (inch) O.D Ø 15.88 (5/8) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole 3-phase induction motor
Input kW - Cool/Heat 2.49/2.41 Rated Output kW - 2.0
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.09 0.11 Rated Output kW 0.04 0.05
Heat - Capillary tube
lbs (8.4) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High and heating pressure switch, Current transformer
Heat Hi 39 Me 37 Lo 35 Hi 53
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F D.B.), 6°C W.B. (42.8°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL CS-A28BB4P, CU-A28BBP8
Condition by JIS B 8615 Volts V 380 400 415 Phase 3N 3N 3N Power Consumption kW Cool 2.69 2.69 2.69
Heat 2.61 2.61 2.61
Running Current A Cool 4.50 4.45 4.40
Heat 4.30 4.25 4.20 Starting Current A 28 29 30 Power Factor % Cool 93 89 87
Heat 92 89 87 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3N~380V, 400V, 451V 50Hz
10
CASSETTE TYPE
3.4. CS-A34BB4P / CU-A34BBP5
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A34BB4P CU-A34BBP5
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL51P (Wireless)
Cooling Capacity kW 10.0
BTU/h 34,100
Heating Capacity kW 11.2
BTU/h 38,200 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 26 Me 23 Lo 20 Hi 70 Medium and Low Speed cfm 918 812 706 2471 Outside Dimension (H x W x D) mm 290 x 840 x 840 1220 x 900 x 320
inch 11-7/16 x 33-1/24 x 33-1/24 48-7/24 x 35-7/16 x 12-19/32
Net Weight kg 30 97
lbs 66 214
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Rotary), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-2
Air-heat Exchanger Slit-fin type Louvre-fin type Refrigerant Control Cool Capillary tube -
Refrigerant Oil (Charged) litre - SONTEX200LT (1.2) Refrigerant (Charged) kg - (4.2)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level Cool dB (A) Hi 45 Me 42 Lo 40 Hi 55
Refrigerant Gas mm (inch) O.D Ø 19.05 (3/4) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole single phase induction motor
Input kW - Cool/Heat 3.23/3.18 Rated Output kW - 2.8
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.15 0.24 Rated Output kW 0.08 0.055 x 2
Heat - Capillary tube
lbs (9.3) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High and heating pressure switch, Current transformer
Heat Hi 45 Me 42 Lo 40 Hi 56
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F D.B.), 6°C W.B. (42.8°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL CS-A34BB4P, CU-A34BBP5
Condition by JIS B 8615 Volts V 220 230 240 Phase Single Single Single Power Consumption kW Cool 3.60 3.60 3.60
Heat 3.55 3.55 3.55
Running Current A Cool 17.0 17.1 17.2
Heat 16.8 16.9 17.0 Starting Current A 94 99 103 Power Factor % Cool 96 92 87
Heat 96 91 87 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 1~220V, 230V, 240V 50Hz
11
3.5. CS-A34BB4P / CU-A34BBP8
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A34BB4P CU-A34BBP8
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL51P (Wireless)
Cooling Capacity kW 10.0
BTU/h 34,100
Heating Capacity kW 11
BTU/h 38,200 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 26 Me 23 Lo 20 Hi 70 Medium and Low Speed cfm 918 812 706 2471 Outside Dimension (H x W x D) mm 290 x 840 x 840 1220 x 900 x 320
inch 11-7/16 x 33-1/24 x 33-1/24 48-1/24 x 35-7/16 x 12-19/32
Net Weight kg 30 97
lbs 66 214
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Rotary), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-2
Air-heat Exchanger Slit-fin type Louvre-fin type Refrigerant Control Cool Capillary tube -
Refrigerant Oil (Charged) litre - SONTEX200LT (1.2) Refrigerant (Charged) kg - (4.2)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level Cool dB (A) Hi 45 Me 42 Lo 40 Hi 55
Refrigerant Gas mm (inch) O.D Ø 19.05 (3/4) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole 3-phase induction motor
Input kW - Cool/Heat 2.93/3.03 Rated Output kW - 2.8
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.15 0.24 Rated Output kW 0.08 0.055 x 2
Heat - Capillary tube
lbs (9.3) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High and heating pressure switch, Current transformer
Heat Hi 45 Me 42 Lo 40 Hi 56
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F D.B.), 6°C W.B. (42.8°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL CS-A34BB4P, CU-A34BBP8
Condition by JIS B 8615 Volts V 380 400 415 Phase 3N 3N 3N Power Consumption kW Cool 3.30 3.30 3.30
Heat 3.40 3.40 3.40
Running Current A Cool 5.70 5.70 5.70
Heat 5.80 5.80 5.80 Starting Current A 39 41 42 Power Factor % Cool 88 84 81
Heat 89 85 82 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3N~380V, 400V, 415V 50Hz
12
CASSETTE TYPE
3.6. CS-A43BB4P / CU-A43BBP8
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A43BB4P CU-A43BBP8
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL51P (Wireless)
Cooling Capacity kW 12.5
BTU/h 42,700
Heating Capacity kW 14.0
BTU/h 47,800 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 30 Me 27 Lo 24 Hi 82 Medium and Low Speed cfm 1059 953 847 2895 Outside Dimension (H x W x D) mm 290 x 840 x 840 1220 x 1100 x 320
inch 11-7/16 x 33-1/24 x 33-1/24 48-7/24 x 35-7/16 x 12-19/32
Net Weight kg 33 114
lbs 73 251
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Rotary), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-2
Air-heat Exchanger Slit-fin type Louvre-fin type Refrigerant Control Cool Capillary tube -
Refrigerant Oil (Charged) litre - SONTEX200LT (2.1) Refrigerant (Charged) kg - (5.2)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level Cool dB (A) Hi 48 Me 46 Lo 44 Hi 55
Refrigerant Gas mm (inch) O.D Ø 19.05 (3/4) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole 3-phase induction motor
Input kW - Cool/Heat 3.85/3.70 Rated Output kW - 3.5
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.17 0.23 Rated Output kW 0.12 0.050 x 2
Heat - Capillary tube
lbs (11.5) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High and heating pressure switch, Current transformer
Heat Hi 48 Me 46 Lo 44 Hi 56
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F D.B.), 6°C W.B. (42.8°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL CS-A43BB4P, CU-A43BBP8
Condition by JIS B 8615 Volts V 380 400 415 Phase 3N 3N 3N Power Consumption kW Cool 4.25 4.25 4.25
Heat 4.10 4.10 4.10
Running Current A Cool 7.3 7.3 7.3
Heat 7.0 7.0 7.0 Starting Current A 58 58 58 Power Factor % Cool 88 84 81
Heat 89 85 81 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3N~380V, 400V, 415V 50Hz
13
3.7. CS-A50BB4P / CU-A50BBP8
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A50BB4P CU-A50BBP8
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL51P (Wireless)
Cooling Capacity kW 14.0
BTU/h 47,800
Heating Capacity kW 15.5
BTU/h 52,900 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 30 Me 27 Lo 24 Hi 86 Medium and Low Speed cfm 1059 953 847 3036 Outside Dimension (H x W x D) mm 290 x 840 x 840 1220 x 1100 x 320
inch 11-7/16 x 33-1/24 x 33-1/24 48-7/24 x 43-5/16 x 12-19/32
Net Weight kg 33 116
lbs 73 256
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Rotary), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-2
Air-heat Exchanger Slit-fin type Louvre-fin type Refrigerant Control Cool Capillary tube -
Refrigerant Oil (Charged) litre - SONTEX200LT (2.1) Refrigerant (Charged) kg - (5.0)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level Cool dB (A) Hi 50 Me 47 Lo 45 Hi 56
Refrigerant Gas mm (inch) O.D Ø 19.05 (3/4) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole 3-phase induction motor
Input kW - Cool/Heat 4.56/4.54 Rated Output kW - 4.1
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.18 0.25 Rated Output kW 0.14 0.055 x 2
Heat - Capillary tube
lbs (11.1) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High and heating pressure switch, Current transformer
Heat Hi 50 Me 47 Lo 45 Hi 58
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F D.B.), 6°C W.B. (42.8°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL CS-A50BB4P, CU-A50BBP8
Condition by JIS B 8615 Volts V 380 400 415 Phase 3N 3N 3N Power Consumption kW Cool 4.99 4.99 4.99
Heat 4.97 4.97 4.97
Running Current A Cool 8.6 8.6 8.6
Heat 8.5 8.5 8.5 Starting Current A 69 69 69 Power Factor % Cool 88 84 81
Heat 89 84 81 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3N~380V, 400V, 415V 50Hz
14
CASSETTE TYPE
4 SPECIFICATION (COOLING ONLY TYPE )
4.1. CS-A24BB4P / CU-C24BBP5
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A24BB4P CU-C24BBP5
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL01P (Wireless)
Cooling Capacity kW 6.3
BTU/h 21,500 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 17 Me 15 Lo 14 Hi 43 Medium and Low Speed cfm 600 530 494 1518 Outside Dimension (H x W x D) mm 240 x 840 x 840 900 x 900 x 320
inch 9-7/16 x 33-1/24 x 33-1/24 35-7/16 x 35-7/16 x 12-19/32
Net Weight kg 26 80
lbs 57 176
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Rotary), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-1
Air-heat Exchanger Slit-fin type Louvre-fin type Refrigerant Control Capillary tube ­Refrigerant Oil (Charged) litre - MS32 (1.3) Refrigerant (Charged) kg - (2.5)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level dB Hi 42 Me 40 Lo 38 Hi 50
Refrigerant Gas mm (inch) O.D Ø 15.88 (5/8) Flared Type
Liquid mm (inch) O.D Ø 6.35 (1/4) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole single phase induction motor
Input kW - Cool 2.31 Rated Output kW - 1.9
Motor Type 4-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.08 0.11 Rated Output kW 0.03 0.05
lbs (11.1) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High pressure switch, Current transformer
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL CS-A24BB4P, CU-C24BBP5
Condition by JIS B 8615 Volts V 220 230 240 Phase Single Single Single Power Consumption kW Cool 2.50 2.50 2.50 Running Current A Cool 11.5 11.1 10.7 Starting Current A 49 51 52 Power Factor % Cool 99 98 97 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 1~220V, 230V, 240V 50Hz
15
4.2. CS-A28BB4P / CU-C28BBP5
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A28BB4P CU-C28BBP5
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL01P (Wireless)
Cooling Capacity kW 7.1
BTU/h 24,200 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 20 Me 18 Lo 16 Hi 43 Medium and Low Speed cfm 706 635 565 1518 Outside Dimension (H x W x D) mm 240 x 840 x 840 900 x 900 x 320
inch 9-7/16 x 33-1/24 x 33-1/24 35-7/16 x 35-7/16 x 12-19/32
Net Weight kg 26 81
lbs 57 179
Piping Connection
Compressor Type, Number of Set - Hermetic- 1 (Rotary), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-1
Air-heat Exchanger Slit-fin type Louvre- fin type Refrigerant Control Capillary tube ­Refrigerant Oil (Charged) litre - MS32 (1.3) Refrigerant (Charged) kg - (3.8)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level dB Hi 44 Me 42 Lo 40 Hi 50
Refrigerant Gas mm (inch) O.D Ø 15.88 (5/8) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole single phase induction motor
Input kW - Cool 2.49 Rated Output kW - 2.0
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.09 0.11 Rated Output kW 0.04 0.05
lbs (11.1) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High pressure switch, Current transformer
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.), and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL CS-A28BB4P, CU-C28BBP5
Condition by JIS B 8615 Volts V 220 230 240 Phase Single Single Single Power Consumption kW Cool 2.69 2.69 2.69 Running Current A Cool 12.3 12.0 11.7 Starting Current A 50 52 54 Power Factor % Cool 99 98 96 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 1~220V, 230V, 240V 50Hz
16
CASSETTE TYPE
4.3. CS-A28BB4P / CU-C28BBP6
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A28BB4P CU-C28BBP6
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL01P (Wireless)
Cooling Capacity kW 7.6
BTU/h 25,900 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 20 Me 18 Lo 16 Hi 43 Medium and Low Speed cfm 706 635 565 1518 Outside Dimension (H x W x D) mm 240 x 840 x 840 900 x 900 x 320
inch 9-7/16 x 33-1/24 x 33-1/24 35-7/16 x 35-7/16 x 12-19/32
Net Weight kg 26 81
lbs 57 179
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Rotary), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-1
Air-heat Exchanger Slit-fin type Louvre-fin type Refrigerant Control Capillary tube ­Refrigerant Oil (Charged) litre - MS32 (1.3) Refrigerant (Charged) kg - (3.8)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level dB Hi 44 Me 42 Lo 40 Hi 53
Refrigerant Gas mm (inch) O.D Ø 15.88 (5/8) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole single phase induction motor
Input kW - Cool 3.00 Rated Output kW - 2.0
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.09 0.11 Rated Output kW 0.04 0.05
lbs (11.1) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High pressure switch, Current transformer
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.), and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
ELECTRICAL DATA (60Hz)
ITEM / MODEL CS-A28BB4P, CU-C28BBP6
Condition by JIS B 8615 Volts V 220 Phase Single Power Consumption kW Cool 3.20 Running Current A Cool 15.3 Starting Current A 70 Power Factor % Cool 95 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 1~220V, 60Hz
17
4.4. CS-A28BB4P / CU-C28BBP8
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A28BB4P CU-C28BBP8
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL01P (Wireless)
Cooling Capacity kW 7.1
BTU/h 24,200 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 20 Me 18 Lo 16 Hi 43 Medium and Low Speed cfm 706 635 565 1518 Outside Dimension (H x W x D) mm 240 x 840 x 840 900 x 900 x 320
inch 9-7/16 x 33-1/24 x 33-1/24 35-7/16 x 35-7/16 x 12-19/32
Net Weight kg 26 81
lbs 57 179
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Rotary), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-1
Air-heat Exchanger Slit-fin type Louvre-fin type Refrigerant Control Capillary tube ­Refrigerant Oil (Charged) litre - MS32 (1.3) Refrigerant (Charged) kg - (3.8)
Running Adjustment
Safety Devices Head thermostat for compressor, Internal thermostat for fan motor,
Noise Level dB (A) Hi 39 Me 37 Lo 35 Hi 50
Refrigerant Gas mm (inch) O.D Ø 15.88 (5/8) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole 3-phase induction motor
Input kW - Cool 2.47 Rated Output kW - 2.0
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.09 0.11 Rated Output kW 0.04 0.05
lbs (11.1) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High pressure switch, Current transformer
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL CS-A28BB4P, CU-C28BBP8
Condition by JIS B 8615 Volts V 380 400 415 Phase 3N 3N 3N Power Consumption kW Cool 2.69 2.69 2.69 Running Current A Cool 4.50 4.45 4.40 Starting Current A 28 29 30 Power Factor % Cool 93 89 87 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3N~380V, 400V, 415V 50Hz
18
CASSETTE TYPE
4.5. CS-A34BB4P / CU-C34BBP5
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A34BB4P CU-C34BBP5
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL01P (Wireless)
Cooling Capacity kW 10.0
BTU/h 34,100 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 26 Me 23 Lo 20 Hi 70 Medium and Low Speed cfm 918 812 706 2471 Outside Dimension (H x W x D) mm 290 x 840 x 840 1220 x 900 x 320
inch 11-7/16 x 33-1/24 x 33-1/24 48-1/24 x 35-7/16 x 12-19/32
Net Weight kg 30 97
lbs 66 214
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Scroll), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-2
Air-heat Exchanger Slit-fin type Louvre-fin type Refrigerant Control Capillary tube ­Refrigerant Oil (Charged) litre - SONTEX200LT(1.2) Refrigerant (Charged) kg - (4.2)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level dB (A) Hi 45 Me 42 Lo 40 Hi 55
Refrigerant Gas mm (inch) O.D Ø 19.05 (3/4) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole single phase induction motor
Input kW - Cool 3.23 Rated Output kW - 2.8
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.15 0.24 Rated Output kW 0.08 0.055 x 2
lbs (11.1) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High pressure switch, Current transformer
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL CS-A34BB4P, CU-C34BBP5
Condition by JIS B 8615 Volts V 220 230 240 Phase Single Single Single Power Consumption kW Cool 3.60 3.60 3.60 Running Current A Cool 17.00 17.10 17.20 Starting Current A 94 99 103 Power Factor % Cool 96 92 87 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 1~220V, 230V, 240V 50Hz
19
4.6. CS-A34BB4P / CU-C34BBP7
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A34BB4P CU-C34BBP7
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL01P (Wireless)
Cooling Capacity kW 10.0
BTU/h 34,100 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 26 Me 23 Lo 20 Hi 70 Medium and Low Speed cfm 918 812 706 2471 Outside Dimension (H x W x D) mm 290 x 840 x 840 1220 x 900 x 320
inch 11-7/16 x 33-1/24 x 33-1/24 48-1/24 x 35-7/16 x 12-19/32
Net Weight kg 30 95
lbs 66 209
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Scroll), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-2
Air-heat Exchanger Slit-fin type Louvre-fin type Refrigerant Control Capillary tube ­Refrigerant Oil (Charged) litre - SONTEX200LT (1.2) Refrigerant (Charged) kg - (4.2)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level dB (A) Hi 45 Me 42 Lo 40 Hi 55
Refrigerant Gas mm (inch) O.D Ø 19.05 (3/4) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole 3-phase induction motor
Input kW - Cool 3.73 Rated Output kW - 2.8
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.15 0.24 Rated Output kW 0.08 0.055 x 2
lbs (11.1) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High pressure switch, Current transformer
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.), and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
ELECTRICAL DATA (60Hz)
ITEM / MODEL CS-A34BB4P, CU-C34BBP7
Condition by JIS B 8615 Volts V 220 Phase 3 Power Consumption kW Cool 3.30 Running Current A Cool 5.70 Starting Current A 39 Power Factor % Cool 88 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3~220V, 60Hz
20
CASSETTE TYPE
4.7. CS-A34BB4P / CU-C34BBP8
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A34BB4P CU-C34BBP8
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL01P (Wireless)
Cooling Capacity kW 10.0
BTU/h 34,100 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 26 Me 23 Lo 20 Hi 70 Medium and Low Speed cfm 918 812 706 2471 Outside Dimension (H x W x D) mm 290 x 840 x 840 1220 x 900 x 320
inch 11-7/16 x 33-1/24 x 33-1/24 48-1/24 x 35-7/16 x 12-19/32
Net Weight kg 30 95
lbs 66 209
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Scroll), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-2
Air-heat Exchanger Slit-fin type Louvre-fin type Refrigerant Control Capillary tube ­Refrigerant Oil (Charged) litre - SONTEX200LT (1.2) Refrigerant (Charged) kg - (4.2)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level dB (A) Hi 45 Me 42 Lo 40 Hi 55
Refrigerant Gas mm (inch) O.D Ø 19.05 (3/4) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole 3-phase induction motor
Input kW - Cool 2.93 Rated Output kW - 2.8
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.15 0.24 Rated Output kW 0.08 0.055 x 2
lbs (11.1) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High pressure switch, Current transformer
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.), and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL CS-A34BB4P, CU-C34BBP8
Condition by JIS B 8615 Volts V 380 400 415 Phase 3N 3N 3N Power Consumption kW Cool 3.30 3.30 3.30 Running Current A Cool 5.70 5.70 5.70 Starting Current A 39 41 42 Power Factor % Cool 88 84 81 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3N~380V, 400V, 415V 50Hz
21
4.8. CS-A43BB4P / CU-C43BBP7
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A43BB4P CU-C43BBP7
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL01P (Wireless)
Cooling Capacity kW 13.5
BTU/h 46,100 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 30 Me 27 Lo 24 Hi 80 Medium and Low Speed cfm 1059 953 847 2824 Outside Dimension (H x W x D) mm 290 x 840 x 840 1220 x 1100 x 320
inch 11-7/16 x 33-1/24 x 33-1/24 48-1/24 x 43-5/16 x 12-19/32
Net Weight kg 33 111
lbs 73 245
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Scroll), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-2
Air-heat Exchanger Slit-fin type Louvre-fin type Refrigerant Control Capillary tube ­Refrigerant Oil (Charged) litre - SONTEX200LT(2.1) Refrigerant (Charged) kg - (5.2)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level dB Hi 49 Me 46 Lo 44 Hi 57
Refrigerant Gas mm (inch) O.D Ø 19.05 (3/4) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole 3-phase induction motor
Input kW - Cool 4.70 Rated Output kW - 3.5
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.17 0.23 Rated Output kW 0.12 0.050 x 2
lbs (11.5) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High pressure switch, Current transformer
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
ELECTRICAL DATA (60Hz)
ITEM / MODEL CS-A43BB4P, CU-C43BBP7
Condition by JIS B 8615 Volts V 220 Phase 3 Power Consumption kW Cool 5.10 Running Current A Cool 15.0 Starting Current A 103 Power Factor % Cool 89 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3~220V, 60Hz
22
CASSETTE TYPE
4.9. CS-A43BB4P / CU-C43BBP8
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A43BB4P CU-C43BBP8
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL01P (Wireless)
Cooling Capacity kW 12.5
BTU/h 42,700 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 30 Me 27 Lo 24 Hi 82 Medium and Low Speed cfm 1059 953 847 2895 Outside Dimension (H x W x D) mm 290 x 840 x 840 1220 x 1100 x 320
inch 11-7/16 x 33-1/24 x 33-1/24 48-1/24 x 43-5/16 x 12-19/32
Net Weight kg 33 111
lbs 73 245
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Scroll), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-2
Air-heat Exchanger Slit-fin type Louvre-fin type Refrigerant Control Capillary tube ­Refrigerant Oil (Charged) litre - SONTEX200LT(2.1) Refrigerant (Charged) kg - (5.2)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level dB Hi 48 Me 46 Lo 44 Hi 55
Refrigerant Gas mm (inch) O.D Ø 19.05 (3/4) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole 3-phase induction motor
Input kW - Cool 3.85 Rated Output kW - 3.5
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.17 0.23 Rated Output kW 0.12 0.050 x 2
lbs (11.5) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High pressure switch, Current transformer
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL CS-A43BB4P, CU-C43BBP8
Condition by JIS B 8615 Volts V 380 400 415 Phase 3N 3N 3N Power Consumption kW Cool 4.25 4.25 4.25 Running Current A Cool 7.30 7.30 7.30 Starting Current A 58 58 58 Power Factor % Cool 88 84 81 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3N~380V, 400V, 415V 50Hz
23
4.10. CS-A50BB4P / CU-C50BBP7
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A50BB4P CU-C50BBP7
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL01P (Wireless)
Cooling Capacity kW 15.1
BTU/h 51,500 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 31 Me 26 Lo 22 Hi 86 Medium and Low Speed cfm 940 788 667 3036 Outside Dimension (H x W x D) mm 290 x 840 x 840 1220 x 1100 x 320
inch 11-7/16 x 33-1/24 x 33-1/24 48-1/24 x 43-5/16 x 12-19/32
Net Weight kg 33 114
lbs 73 251
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Scroll), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-2
Air-heat Exchanger Slit-fin type Louvre- fin type Refrigerant Control Capillary tube ­Refrigerant Oil (Charged) litre - SONTEX200LT(2.1) Refrigerant (Charged) kg - (5.0)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level dB Hi 49 Me 46 Lo 43 Hi 58
Refrigerant Gas mm (inch) O.D Ø 19.05 (3/4) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x1
Starting Method - Direct on-line starting Motor Type - 2-pole 3-phase induction motor
Input kW - Cool 5.55 Rated Output kW - 4.1
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.25 0.25 Rated Output kW 0.095 0.055 x 2
lbs (11.0) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High pressure switch, Current transformer
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
ELECTRICAL DATA (60Hz)
ITEM / MODEL CS-A50BB4P, CU-C50BBP7
Condition by JIS B 8615 Volts V 220 Phase 3 Power Consumption kW Cool 6.0 Running Current A Cool 17.7 Starting Current A 149 Power Factor % Cool 89 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3~220V 60Hz
24
CASSETTE TYPE
4.11. CS-A50BB4P / CU-C50BBP8
ITEM / MODEL Indoor Unit Outdoor unit
Main Body CS-A50BB4P CU-C50BBP8
Panel CZ-BT01P
Remote CZ-RD51P (Wired)
Control CZ-RL01P (Wireless)
Cooling Capacity kW 14.0
BTU/h 47,800 Refrigerant Charge-less m 30 Standard Air Volume for High, m3/min Hi 30 Me 27 Lo 24 Hi 86 Medium and Low Speed cfm 1059 953 847 3036 Outside Dimension (H x W x D) mm 290 x 840 x 840 1220 x 1100 x 320
inch 11-7/16 x 33-1/24 x 33-1/24 48-1/24 x 43-5/16 x 12-19/32
Net Weight kg 33 114
lbs 73 251
Piping Connection
Compressor Type, Number of Set - Hermetic-1 (Scroll), 1
Fan Type, Number of Set Turbo fan-1 Propeller fan-2
Air-heat Exchanger Slit-fin type Louvre- fin type Refrigerant Control Capillary tube ­Refrigerant Oil (Charged) litre - SONTEX200LT (2.1) Refrigerant (Charged) kg - (5.0)
Running Adjustment
Safety Devices Internal protector for compressor, Internal thermostat for fan motor,
Noise Level dB Hi 50 Me 47 Lo 45 Hi 56
Refrigerant Gas mm (inch) O.D Ø 19.05 (3/4) Flared Type
Liquid mm (inch) O.D Ø 9.52 (3/8) Flared Type
Drain mm O.D Ø 20 I.D Ø 20 x 1
Starting Method - Direct on-line starting Motor Type - 2-pole 3-phase induction motor
Input kW - Cool 4.56 Rated Output kW - 4.1
Motor Type 6-pole single phase induction motor 6-pole single phase induction motor
Input kW 0.18 0.25 Rated Output kW 0.14 0.055 x 2
lbs (11.0) Control Switch Wireless or Wired Remote Control ­Room Temperature Thermostat (Main Body) -
Crankcase heater, High pressure switch, Current transformer
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL CS-A50BB4P, CU-C50BBP8
Condition by JIS B 8615 Volts V 380 400 415 Phase 3N 3N 3N Power Consumption kW Cool 4.99 4.99 4.99 Running Current A Cool 8.60 8.60 8.60 Starting Current A 69 69 69 Power Factor % Cool 88 84 81 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3N~380V, 400V, 415V 50Hz
25
5 TECHNICAL DRAWING
26
CASSETTE TYPE
27
28
CASSETTE TYPE
29
30