PANASONIC CU5E34NBE, CSME18NKE, CSME24NKE User Manual

CV623318773085264181224000
Operating Instructions
Split System Air Conditioner
Model No. Indoor Units
CS-ME18NKE CS-ME24NKE
Outdoor Units
EΛΛΗΝΙΚΆ 110 ~ 126
Πριν θέσετε τη μονάδα σε λειτουργία, διαβάστε πολύ καλά αυτές τις οδηγίες χρήσης και διατηρήστε τις για μελλοντική αναφορά.
ENGLISH 2 ~ 19
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
ESPAÑOL 20 ~ 37
Antes de operar la unidad, lea atentamente estas instrucciones de funcionamiento y guárdelas para futuras consultas.
FRANÇAIS 38 ~ 55
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.
DEUTSCH 56 ~ 73
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die künftige Verwendung auf.
ITALIANO 74 ~ 91
Prima di utilizzare l’unità, leggere a fondo queste istruzioni per l’uso e conservarle come riferimento futuro.
PORTUGUÊS 92 ~ 109
Antes de utilizar o aparelho, leia completamente este manual de instruções e guarde-o para futuras referências.
© Panasonic Corporation 2012 Unauthorized copying and distribution is a violation of law.
2
FEATURES
This air conditioner is an inverter type unit that automatically adjusts capability as appropriate. Details on these functions are provided below; refer to these descriptions when using the air conditioner.
• Microprocessor Controlled Operation
The interior compartment of the remote controller contains several features to facilitate automatic operation, easy logically displayed for easy use.
• Simple One-touch Remote Controller
The remote controller has several features to facilitate automatic operation.
• 24-Hour ON or OFF Timer
This timer can be set to automatically turn the unit on or off at any time within a 24 hour period.
• 1-Hour OFF Timer
This timer can be set to automatically turn off the unit at any time after one hour.
• Night Setback
This function saves energy by controlling operation to provide a quieter operating sound than normal.
• Automatic and 3-step Fan Speed
Auto/High/Medium/Low
• Air Sweep Control
This function moves a flap up and down in the air outlet, directing air in a sweeping motion around the room and providing comfort in every corner.
• Auto. Flap Control
This automatically sets the flap to the optimum position during heating, cooling, and drying operation.
• Hot Start Heating System
Right from the start, the air is warm and comfortable. This system prevents any cold blasts at the beginning while the heat pump is warming up, or even defrosting.
• Automatic Restart Function for Power Failure
Even when power failure occurs, preset programmed operation can be reactivated once power resumes.
• High Power Operation
If not in Auto Operation, the unit operates at maximum output for 30 minutes, regardless of the desired temperature. The fan speed is 1 step above “High”.
• Quiet Operation
The fan rotates slower than the fan speed setting to provide a quieter operating sound.
• Anti-Mold Filter
This unit is equipped with an anti-mold filter that inhibits the growth of mold and bacteria.
• Air Clean Filter
An air filter that eliminates unpleasant odors and cleans the air is available. Purchase a replacement filter at your local dealer. (model CZ-SA1U)
CONTENTS
Page
FEATURES.........................................................................................................................................2
PRODUCT INFORMATION ................................................................................................................3
SAFETY PRECAUTIONS...................................................................................................................3
INSTALLATION LOCATION................................................................................................................3
ELECTRICAL REQUIREMENTS........................................................................................................3
SAFETY INSTRUCTIONS..................................................................................................................4
INFORMATION...................................................................................................................................5
NAMES OF PARTS.............................................................................................................................6
USING THE REMOTE CONTROLLER ............................................................................................10
OPERATION WITH THE REMOTE CONTROLLER.........................................................................11
1. Automatic Operation.......................................................................................................... 11
2. Manual Operation..............................................................................................................11
3. Adjusting the Fan Speed ...................................................................................................12
4. Night Setback Mode..........................................................................................................12
5. QUIET Mode .....................................................................................................................12
6. HIGH POWER Mode.........................................................................................................13
SPECIAL REMARKS........................................................................................................................13
SETTING THE TIMER...................................................................................................................... 14
USING THE 1-HOUR OFF TIMER...................................................................................................15
TIPS FOR ENERGY SAVING........................................................................................................... 15
ADJUSTING THE AIRFLOW DIRECTION .......................................................................................15
OPERATION WITHOUT THE REMOTE CONTROLLER ................................................................. 16
CARE AND CLEANING....................................................................................................................16
TROUBLESHOOTING (BEFORE CALLING FOR SERVICE)..........................................................17
OPERATING RANGE.......................................................................................................................17
SPECIFICATIONS ............................................................................................................................18
3
PRODUCT INFORMATION
If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the bottom of the cabinet.
Model No. _______________________________________________________________________ Serial No.________________________________________________________________________ Date of purchase __________________________________________________________________ Dealer’s address __________________________________________________________________ Phone number ____________________________________________________________________
SAFETY PRECAUTIONS
The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance:
INSTALLATION LOCATION
• We recommend that this air conditioner be installed properly by qualified installation technicians in
accordance with the Installation Instructions provided with the unit.
• Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage
shown on the nameplate.
Avoid:
To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa.
ELECTRICAL REQUIREMENTS
1. All wiring must conform to the local electrical codes. Consult your dealer or a qualified electrician for details.
2. Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring.
3. Wiring must be done by a qualified electrician.
Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate
the air conditioner from the main power supply when not in use for a long time.
This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.
• Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid
space such as a greenhouse.
• Do not install the air conditioner where excessively high heat-generating objects are placed.
NOTE
CAUTION
4
SAFETY INSTRUCTIONS
• Read these Operating Instructions carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.
• This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in these Operating Instructions.
Confirm to authorized dealer or specialist on usage of specified refrigerant type. Using of refrigerant other than the specified type may cause product damage, burst and injury etc.
Never touch the unit with wet hands. Never use or store gasoline or other flammable vapor or liquid
near the air conditioner — it is very dangerous. Do not use this appliance in a potentially explosive atmosphere. This air conditioner has no ventilator for intaking fresh air from
outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case.
Do not swallow the battery. After removing the battery from remote controller, keep it away
from the reach of children. The battery can cause death by suffocation if swallowed.
When inserting the battery, make sure the polarities (+ and -) are correct.
Provide a power outlet to be used exclusively for each unit, and a power supply disconnect, circuit breaker and earth leakage breaker for overcurrent protection should be provided in the exclusive line.
Provide a power outlet exclusively for each unit, and full disconnection means having a contact separation in all poles must be incorporated in the fixed wiring in accordance with the wiring rules.
To prevent possible hazards from insulation failure, the unit must be grounded.
Do not clean inside the indoor and outdoor units by users. Engage authorized dealer or specialist for cleaning.
In case of malfunction of this appliance, do not repair by yourself. Contact to the sales dealer or service dealer for a repair.
Refrigerant gas leakage may cause fire. For safety, be sure to turn the air conditioner off and also
to disconnect the power before cleaning or servicing. Pull off the power plug from a receptacle, or switch off the
breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency.
Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.
Do not use modified cord, joint cord, extension cord or unspecified cord to prevent overheating and fire.
Stop using the product when any abnormality/failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fire/electric shock) Examples of abnormality/failure
• The ELCB trips frequently.
• Burning smell is observed.
• Abnormal noise or vibration of the unit is observed.
• Water leaks from the indoor unit.
• Power cord or plug becomes abnormally hot.
• Fan speed cannot be controlled.
• The unit stops running immediately even if it is switched on for operation.
• The fan does not stop even if the operation is stopped.
Contact immediately your local dealer for maintenance/repair.
Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button.
Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed.
Do not touch the air inlet or the sharp aluminum fins of the outdoor unit. You may get injured.
Keep the fire alarm and the air outlet at least 1.5m away from the unit.
This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that do not play with the appliance.
Do not cool or heat the room too much if babies or invalids are present.
Do not sit or step on the unit. You may fall down accidentally.
Do not stick any object into the FAN CASE. You may be injured and the unit may be damaged.
CAUTION
5
INFORMATION
The compressor may occasionally stop during thunderstorms. This is not a mechanical failure. The unit automatically recovers after a few minutes.
The English text is the original instructions. Other languages are translation of the original instructions.
NOTICE
Stop using the product when any abnormality/failure occurs and disconnect the power plug.
(Risk of smoke/fire/electric shock)
Examples of abnormality/ failure
- The product sometimes does not start when turned on.
- The power is sometimes disconnected when the cord is moved.
- Burnt odor or abnormal noise is detected during operation.
- The body is deformed or abnormally hot.
Contact immediately your local dealer for maintenance/repair.
Information for Users on Collection and Disposal of Old Equipment and Used Batteries
These symbols on the products, packaging, and/or accompanying documents mean that used electrical and electronic products and batteries should not be mixed with general household waste. For proper treatment, recovery and recycling of old products and used batteries, please take them to applicable collection points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC. By disposing of these products and batteries correctly, you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling. For more information about collection and recycling of old products and batteries, please contact your local municipality, your waste disposal service or the point of sale where you purchased the items. Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.
For business users in the European Union
If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information.
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved.
Pb
6
NAMES OF PARTS
This illustration is based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner which you have selected.
This air conditioner consists of an indoor unit and an outdoor unit. You can control the air conditioner with the remote controller.
UNIT DISPLAY AND OPERATION BUTTON
Avoid using radio equipment such as mobile phone near (within 1 m) the remote control receiver. Some radio equipment may cause malfunction of the unit.
If the trouble happens, disconnect power and restart the air conditioner after a few minutes.
The unit’s display lamps are dimmed during operation in the NIGHT SETBACK mode.
NOTE
Air Intake
Air from the room is drawn into this section and passes through air filters which remove dust.
Air Outlet
Conditioned air is blown out of the air conditioner through the air outlet.
Remote Controller
The remote controller controls power ON/OFF, operation mode selection, temperature, fan speed, timer setting, and air sweeping.
Refrigerant Tubes
The indoor and outdoor units are connected by copper tubes through which refrigerant gas flows.
Drain Hose
Moisture in the room condenses and drains off through this hose.
Outdoor (Condensing) Unit
The outdoor unit contains the compressor, fan motor, heat exchanger coil, and other electrical components.
INDOOR UNIT
Air Intakes
Remote Controller
Air Outlet
Refrigerant Tubes
Drain Hose
OUTDOOR UNIT
Air Outlet
REMOTE CONTROL receiver
This section picks up infrared signals from the remote controller (transmitter).
OPERATION button
When the remote controller cannot be used, pressing this button enables heating and cooling operation.
Each time this button is pressed, the type of operation conducted is indicated by the changing color of the OPERATION lamp. Press the button and select the lamp color that suits your preference for operation.
OPERATION lamp
This lamp lights when the system is in the continuous AUTO (red or green), HEAT (red), DRY (orange) and COOL (green) mode. The OPERATION lamp lights up red and orange alternately when the system is defrosting.
TIMER lamp This lamp lights when the system is being
controlled by the timer.
NOTE
REMOTE CONTROL receiver
OPERATION lamp
TIMER lamp
OPERATION button (ON/OFF )
INDOOR UNIT
IMPORTANT
Cooling
operation
(green)
Heating
operation
(red)
Stop
(lamp off)
Loading...
+ 14 hidden pages