Panasonic CS-V7DKE, CU-V7DKE, CS-V9DKE, CU-V9DKE, CS-V12DKE Operating Instructions Manual

...
Q
U
I ET
POWERFUL
I O
N
T I
M
W
ER
F564973
CS-V7DKE CU-V7DKE CS-V9DKE CU-V9DKE CS-V12DKE CU-V12DKE
Manufactured by:
Panasonic HA Air-Conditioning (M) Sdn. Bhd.
Lot 2, Persiaran Tengku Ampuan, Section 21, Shah Alam Industrial Site, 40300 Shah Alam, Selangor, Malaysia.
ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference. 2 ~ 7 ESPAÑOL Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta. 8 ~ 13 ITALIANO Prima di utilizzare l’unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi fare riferimento in futuro. 14 ~ 19 NEDERLANDS Lees voor u het apparaat gebruikt deze gebruiksinstructies grondig na en bewaar ze voor toekomstig gebruik. 20 ~ 25 PORTUGUÊS Antes de ligar a unidade, leia cuidadosamente este manual de utilização e guarde-o para futura referência. 26 ~ 31 EΛΛΗΝΙΚΆ Προτού θέσετε τη μονάδα σε λειτουργία, διαβάστε προσεκτικά αυτές τις οδηγίες χρήσης και φυλάξτε τις για μελλοντική αναφορά. 32 ~ 37 БЪЛГАРСКИ Преди да задействате климатика, прочетете внимателно инструкциите за употреба и ги запазете за бъдещи справки. 38 ~ 43
Operating Instructions
Air Conditioner
2
(GB Standard)
Installation Precautions
Installation Precautions
Caution
• Do not pull the cord to disconnect the plug.
• Do not wash the unit with water, benzene, thinner or scouring powder.
• Do not use for other purposes such as preservation of food.
• Do not use any combustible equipment at airfl ow direction.
• Do not sit or place anything on the indoor or outdoor unit.
• Do not expose directly to cold air for a long period.
• Ventilate the room regularly.
• Pay attention as to whether the installation rack is damaged after long period of usage.
• Switch off the power supply and unplug before cleaning or servicing.
• Turn off the power supply and unplug if the unit is not used for a long period of time.
Operation Precautions
Operation Precautions
• Insert the power plug properly.
• Use specifi ed supply cord.
• If the supply cord is damaged or needed to be replaced, it must be replaced by the manufacturer or its service agent or a similarly qualifi ed person in order to avoid a hazard.
• Remove the batteries if the unit is not going to be use for a long period of time.
New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.
• In case of emergency or abnormal condition (burnt, smell, etc) occurs, turn off the power supply and unplug.
• Do not share power outlet.
• Do not modify power cord.
• Do not use an extension cord.
• Do not operate with wet hands.
• Do not operate or stop the unit by inserting or pulling out the power plug.
• Do not insert fi nger or other objects into the indoor or outdoor unit.
• Do not attempt to repair the unit by yourself.
• Do not use rechargeable (Ni-Cd) batteries.
• Keep the remote control away from infants and small children to prevent them from accidentally swallowing the batteries.
Warning
Warning
Do not install, remove and reinstall the unit by yourself.
• Improper installation will cause leakage, electric shock or fi re. Please consult an authorized dealer or specialist for the installation work.
• This equipment must be earthed and installed with ELCB. It may cause electrical shock or fi re in case of malfunction
Caution
• This air conditioner must be earthed. Improper grounding will cause electric shock.
• Ensure that the drainage piping is connected properly. Otherwise, water will leak.
• Do not install the unit in a potentially explosive atmosphere.
This sign warns of death
or serious injury.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Replacement or installation of power plugs shall be performed by authorized/qualifi ed personnel only. The wires in this mains lead are coloured in accordance with the following code:
To prevent personal injury, injury to others and property damage, the following instructions must be followed.
Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classifi ed as below:
Thank you for purchasing Panasonic Air Conditioner
SAFETY PRECAUTIONS
This symbol denotes
an action that is
PROHIBITED.
These symbols denote
actions that are
COMPULSORY.
Warning
Definition
This sign warns of injury
or damage to property.
Caution
The instructions to be followed are classifi ed by the following symbols:
Safety Regulation
Operation Condition (OC)
Use this air conditioner under the following temperature range.
DBT: Dry Bulb Temperature WBT: Wet Bulb Temperature
Indoor Outdoor
DBT WBT DBT WBT
Maximum Temperature 32 23 43 26
Minimum Temperature 16 11 16 11
Different countries may have different colour coding for the wires.
3
Q
U
I
E
T
POW
E
R
F
U
L
I
O
N
T
I
M
E
R
P
OWE
R
CANCEL
O
F
F
TI
M
E
R
ON
TIME
R
FAN S
PEED
AIR
S
W
I
NG
A
UTO
DRY
COO
L
MODE
TIMER
ON
123
O
FF
CLOCK RES
E
T
SET
CANCEL
TEMP
P
OWE
RFUL
FA
N
SPE
E
D
AIR SWIN
G
OFF/ON
QUIET
QUIET
POWERFUL
ION
SUPER
ALLERU-BUSTER
TIMERPOWER
ENGLISH
Note: The illustrations in this manual are for explanation purposes only and may differ from the
actual unit. It is subjected to change without notice for future improvement.
PRODUCT OVERVIEW
Air intake
Airflow direction louver
Ionizer
Air filter
Front panel
Indoor Unit
Indoor Unit
Outdoor Unit
Outdoor Unit
Air inlet (rear)
Air outlet
LCD display
Off/On
Fan speed selection
Clock setting
Memory reset
Temperature setting
Powerful operation
Operation mode
Quiet operation
Timer setting
Ion operation
Airflow direction adjustment
Remote Control
Remote Control
Indicator
OP
E
N
• Make sure it is not obstructed.
• Maximum distances: 10m.
• Certain fluorescent lights may interfere with signal transmission. Consult your dealer.
Remote Control Preparation
About
Remote Control Signal
• Timer operation will be based on current time set.
• The batteries can be used for approximately 1 year.
• The batteries must be recycled or disposed of properly.
1. Pull out
2. Insert batteries (AAA or R03)
3. Press CLOCK button
4. Set current time
5. Press again to confi rm
Supersonic air purifying device
Auto OFF/ON button
Receiver
Troubleshooting
Operation delayed for few minutes after restart.
This is a normal self protection control.
Sound like water owing during operation.
Caused by refrigerant ow inside.
Mist emerges from indoor unit.
Condensation effect due to cooling process.
Noisy during operations.
Installation work could be slanted or front panel didn’t close properly.
Remote control/display does not work.
Check whether batteries are correctly inserted or need replacement.
The unit cannot operate.
Check either circuit breaker is tripped, power plug is inserted correctly or
timer is used correctly.
Outdoor unit emits water/steam.
Condensation or evaporation happens at piping surface.
Transmitter
Air inlet (side)
Discharged air
Do not touch during operation
• To operate the unit if the remote control is misplaced or malfunctioning.
Action
Operation
mode
Press once
Automatic
Operation
Press until “beep”
sound
Cooling
Operation
• To OFF, press again the Auto OFF/ ON button.
• To switch the remote control signal receiving sound off or on.
1. Press until “beep” sound and
release.
2. Press again until “beep-beep”
sound and release.
3. Press to switch the sound off or
on.
(Long “beep” - OFF; short “beep”
- ON)
Auto OFF/ON Button