Panasonic CU-SA9CKP5, CS-SA9CKP, CU-SA12CKP5, CS-SA12CKP User Manual

Before using your air-conditioner, please read this operating instructions carefully and keep it for future reference.
Split Type Room Air Conditioner
OPERATING INSTRUCTIONS
Indoor Unit Model:
CS-SA9CKP
CS-SA12CKP
CU-SA9CKP5
CU-SA12CKP5
ENGLISH ...................... P. 1 ——P. 8
PORTUGUÊS ............... P. 9 ——P. 16
DEUTSCH..................... P. 17 ——P. 24
FRANÇAIS.................... P. 25 ——P. 32
NEDERLAND................ P. 33 ——P. 40
ITALIANO ..................... P. 41 ——P. 48
GREEK ......................... P. 49 ——P. 56
ESPAÑOL..................... P. 57 ——P. 64
RUSSIAN ...................... P. 65 ——P. 73
F563553/01-08/EN 5/6/02, 10:34 am1
MATSUSHITA AIR-CONDITIONING CORP. XIECUN, ZHONGCUN TOWN, PANYU DISTRICT. GUANGZHOU CITY, GUANGDONG PROVINCE, CHINA
F563553
Thank you very much for purchasing Panasonic Split Type Room Air Conditioner.
CONTENTS
33
3
Safety Precautions ...................................... 1~2
33
Installation Precautions
Operation Precautions
33
3
Name of Each Part....................................... 2~3
33
Indoor Unit
Outdoor Unit
Accessories
33
3
Basic Operation ........................................... 4~5
33
33
3
Setting the Timer...............................................5
33
33
3
Care and Maintenance ................................ 5~6
33
Cleaning the lndoor Unit and Remote Control
Cleaning the Air Filter
Cleaning the Front Panel
Pre-season lnspection
When the Air Conditioner is Not Used for an
Extended Period of Time
Recommended lnspection
33
3
Helpful Information...........................................6
33
33
3
Energy Saving and Operation Hints ............... 6
33
33
3
Trouble Shooting ..............................................7
33
Normal Operation
Abnormal Operation
Call the Dealer lmmediately
SAFETY PRECAUTIONS
Before operating, please read the following “Safety Precautions” carefully.
To prevent personal injury, injury to others and property damage, the following instructions must be followed.
Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classified as follow:
Warning
This sign warns of death or serious injury.
Caution
This sign warns of injury or damage to property.
The instructions to be followed are classified by the following symbols:
This symbol (with a white background) denotes an
action that is PROHIBITED.
Installation Precautions
Warning
Do not install, relocate or repair the unit by yourself.
This air conditioner must be earthed.
Improper grounding could cause electric shock or fire.
Caution
Ensure that the following installation precautions have been applied before installing the air conditioner.
The power socket must be earthed.
Improper grounding may cause current leakage.
Ensure that the drainage pipings are
properly connected.
Water leakage could happen due to improper connection thus cause inconvenience.
Do not install the unit in a potentially
explosive atmosphere. Otherwise, fire or other hazard may occur.
33
3
Evaluation of the Performance........................ 8
33
33
3
Safety Notes......................................................8
33
1
F563553/01-08/EN 5/6/02, 10:34 am2
These symbols (with a black background) denote
actions that are COMPULSORY.
Operation Precautions
Warning
This sign warns of death or serious injury.
ENGLISH
NAME OF EACH PART
3
Indoor Unit
2
1
Outdoor Unit
1
2
3
Do not share outlet.
Do not insert plug to operate the unit. Do not
pull out plug to stop the unit.
Do not operate with wet hands.
Do not damage or modify the power cord.
Do not insert finger or other objects into the
indoor or outdoor units.
Do not expose directly to cold air for a long period.
Plug in properly.
Use specified power cord.
If abnormal condition (burnt smell, etc.)
occurs, switch off and unplug the power supply.
Caution
This sign warns of injury.
Do not pull the cord to disconnect the plug.
Do not wash the unit with water.
Do not use for other purposes such as
preservation.
Do not use any combustible equipment at airflow direction.
Do not sit or place anything on the outdoor unit.
Switch off the power supply before cleaning.
Ventilate the room regularly.
Pay attention as to whether the installation
rack is damaged after long period of usage.
Switch off the power supply if the unit is not used for a long period.
4
1
Front Panel
2
Air Intake Vent
3
Power Supply Cord
4
Air Outlet Vent
5
Vertical Airflow Direction Louver
6
Horizontal Airflow Direction Louver
5
6
7
9
8
(manually adjusted)
7
Auto Operation Button (when the front panel is opened)
8
Air Filters
9
Indicator Panel
POWER: Green (Operation)
TIMER: Orange
Auto Operation /Test Run Operation
If the remote control not available, press the button for Auto Operation. Keeping this button depressed for more than 5 seconds to start the Test Run Operation (cooling only), for the purpose of installation or repairment only.
3
6
1
Air Intake Vents
2
Ground Terminal
1
4
5
2
3
(Inside cover)
3
Piping
4
Connecting Cable
5
Drain Hose
6
Air Outlet Vent
6
4
5
Accessories
Remote Control
Two dry-cell batteries.
F563553/01-08/EN 5/6/02, 10:34 am3
2
NAME OF EACH PART
Remote Control
1
Signal Transmitter
2
Display Panel
3
Room Temperature Setting Button
4
Operation Mode Selection Button
5
OFF-Timer Button
6
ON-Timer Button
7
Timer Cancellation Button
8
Timer Setting Button
9
Operation Button (OFF/ON)
Ä
Fan Speed Selection Button
Å
Airflow Direction Control Button
Display of air flow direction, changing as follow:
Ç
RESET Button If the display is chaotic or can not be adjusted, use a pin to gently press this button to reset the remote control to the original set by manufacturer.
Remote Control Signal
Make sure it is not obstructed.
Maximum distance: 10 m.
Signal received sound.
One short beep or one long beep.
Notes for Remote Control
Direct the remote control towards the signal
receiver of the Indoor Unit.
Do not drop or throw the remote control.
Do not leave the remote control in a place subject to
direct sunlight or near heat sources such as radiator.
Do not get it wet.
How to Insert the Batteries
1 Remove the remote control back cover completely 2 Insert the batteries
– Be sure the direction is correct
About the Batteries
Can be used for approximately one year.
Observe the Following When Replacing
the Batteries
1 Replace with two new batteries of the same type. 2 Do not use rechargeable batteries (Ni-Cd). 3 Remove the batteries if the unit is not to be used
for a long period.
To Start the Operation
Press operation OFF/ON buton.
POWER indicator (green) on the indoor unit will
light up.
To stop, press operation OFF/ON once more.
Setting Mode
Press MODE to select:
AUTO – Automatic Operation HEAT – Heating Operation COOL – Cooling Operation DRY – Soft Dry Operation
Setting Temperature
Press TEMP to increase or decrease the
temperature.
The temperature can be set between 16˚C ~ 30˚C.
Recommended setting temperature:
Heating – 19˚C ~ 23˚C Cooling – 24˚C ~ 26˚C Soft Dry – 20˚C ~ 24˚C
Fan Speed Control
Press FAN SPEED to select:
Fan Speed Remote Control
Display
AUTO LO MED HIGH
AUTO Fan Speed
Fan Speed Fan Speed Fan Speed
3
F563553/01-08/EN 5/6/02, 10:34 am4
AUTO
Automatic Operation
1 Press operation selection MODE button, the
cursor key points to AUTO .
2 Press operation OFF/ON button, the operation
lamp of the air conditioner will flash momentarily, and then lights up.
Notes: 1. During Automatic Operation, the operation
mode will be selected automatically in accordance with the room temperature.
C
Intake air temperature
2. During Automatic Operation, the adjustable temperature range is ±2°C. By pressing or button, or will appear in the remote control display accordingly.
3. During Automatic Operation with AUTO Fan Speed:
Heating: When the room temperature is low, the fan
will be at low speed. As the room temperature rising, fan will speed up.
Cooling: Auto Fan Speed will run at a High fan
speed initially. It stops when it reaches the set temperature. Then, it will start operating again at Low fan speed. During Cooling and Soft Dry operations, the fan will start operating 40 seconds later.
Cooling Operation
23˚C
Soft Dry Operation
20˚C
Heating Operation
Heating Operation
1 Press operation selection MODE button, the
cursor key points to HEAT .
2 Press operation OFF/ON button, the operation
lamp of the air conditioner will flash momentarily, and then lights up.
3 Press or button to set the room temperature.
Notes:
● Heat is obtained from outdoor air to warm up the room. When the outdoor ambient air temperature falls, the heating capacity of the unit might be reduced.
Defrosting Operation Depend on the outdoor temperature, the operation occasionally stops to melt the frost on the outdoor unit.
ENGLISH
Cooling Operation
1 Press operation selection MODE button, the
cursor key points to COOL .
2 Press operation OFF/ON button, the operation
lamp of the air conditioner will light up.
3 Press or button to set the room temperature.
Note: When setting the automatic airflow during
Cooling Operation, changes in speed and movements of louvers, which swing in up and
down manner forms a natural breeze condition.
Soft Dry Operation
1 Press operation selection MODE button, the
cursor key points to DRY .
2 Press operation OFF/ON button, the operation
lamp of the air conditioner will light up.
3 Press or button to set the room temperature.
Notes: 1. The purposes of Soft Dry Operation : to
maintain the room temperature at the set temperature, prior to dehumidification.
2. When setting the automatic airflow during Soft Dry Operation, changes in speed and movements of louvers, which swing in up and down manner forms a natural breeze condition.
3. During Soft Dry Operation, the fan will run at Low fan speed, and on/off operation will occur occasionally.
F563553/01-08/EN 5/6/02, 10:34 am5
Recommendation : Select this mode in the rainy day
or when the humidity is high.
4
Setting the Vertical Airflow Direction
E
O
CANCEL
ON
S
D
G
Press AIR SWING button to select.
The adjustment angles of the airflow direction
louvers for Heating, Cooling and Soft Dry operations are different.
Cooling/Soft Dry approx. 36˚
Heating approx. 55˚
* 5 adjustment
Ensure that the angles of the vertical airflow direction louvers are adjusted by using the remote control. If it were manually adjusted, the proper mechanism of the louvers may be affected. If such a case, turn off the air conditioner temporarily and then restart the operation.
During Cooling and Soft Dry operations, please avoid the vertical airflow direction louvers from positioning in a downward direction for a long period. Otherwise, if condensation occured near the airflow direction louver and air outlet vents, it may result in water dripping.
To adjust the horizontal airflow direction, manually move the Horizontal Airflow Direction Louver.
To move the Vertical Air Flow Direction Louver by hand.
After the air conditioner stopped and restarted immediately, the compressor will not operate within 3 minutes. (For compressor protection purposes.)
Closed
angles available.
SETTING THE TIMER
MOD
FF
ON-TIMER Operation
To start the air conditioner operation automatically.
Press ON to set the operation.
Press ON to increase or decrease the time.
Then press SET .
To cancel this operation, press CANCEL .
OFF-TIMER Operation
To stop the air conditioner operation automatically.
Press OFF to set the operation.
Press OFF to increase or decrease the time.
Then press SET .
To cancel this operation, press CANCEL .
The OFF-TIMER can only be set while the
air-conditioner is in operation.
Timer Mode Operation Details
The ON-TIMER and OFF-TIMER cannot be set
simultaneously.
The set time that appears on the remote control display is actually the remaining set time which will appear after every hour of operation.
If you press operation OFF/ON button during the timer setting operation, timer setting will be cancelled. (The timer indicator of the Indoor Unit will go off.)
When the ON-Timer is set, operation will start before the actual set time. This is to enable room temperature reaches the set temperature at the set time.
COOL – 15 minutes in advance HEAT, AUTO – 30 minutes in advance
AN SPEE
AIR SWIN
ET
RESET
CARE AND MAINTENANCE
Cleaning the Indoor Unit and Remote Control
Wipe gently with a piece of soft, dry cloth.
Do not use water hotter than 40˚C or polishing fluid to
clean the unit.
Cleaning the Air Filter
(Recommendation:- If the unit is operated in a dusty environment, clean the filters every two weeks, continuous use of this dirty filters will reduce cooling or heating efficiency)
1 Remove dirt using a vacuum cleaner. 2 Wash back of the air filter with water. 3 If badly soiled, wash it with soap or a mild household
detergent.
4 Let it dry and reinstall it.
* Be sure the FRONT mark is facing you.
Damaged air filter.
Consult the nearest authorized dealer. Part No.: CWD001050.
Do not use benzene, thinner, scouring powder or cloth soaked in caustic chemical to clean the unit.
Cleaning the Front Panel
(Must be removed before washing)
1 Raise the front panel higher than the horizontal and
pull to remove it.
2 Gently wash with water and a sponge.
Do not press the front panel too hard when washing.
When use kitchen cleaning fluid (neutral
detergent), rinse thoroughly.
Do not dry the front panel under direct sunlight.
3 T o fix the front panel, raise the front panel
horizontally , match the protruding portion on the indoor unit to the fulcrum and push into place.
Fulcrum
Front grille pivot
5
F563553/01-08/EN 5/6/02, 10:34 am6
Pre-season Inspection
Is the discharged air cold/warm?
Operation is normal if 15 minutes after the start of operation, the difference between the air intake and outlet vents temperature is:-
Cooling – 8˚C or above Heating – 14˚C or above
Are the air intake or outlet vents of the indoor
or outdoor units obstructed?
Are the remote control batteries weak?
If the remote control display appears weak, replace the batteries.
When the Air Conditioner is Not To Be Used
for an Extended Period of Time 1 To dry the internal parts of the indoor unit, operate
the unit for 2 – 3 hours using:
Operation mode : cooling Set temperature : 30˚C
2 Turn off the power supply and unplug. 3 Remove the remote control batteries.
Recommended Inspection
After used over several seasons, the unit will
become dirty and thus decreases the unit's performance. Depending on the operation conditions, a dirty unit may produce odour and dust may pollute dehumidification system. Therefore, a seasonal inspection is recommended in addition to regular cleaning. (Consult an authorized dealer).
HELPFUL INFORMATION
Auto Operation Button
Automatic Operation
If the remote control fails to function or has been
misplaced, press the Auto Operation button to start the Automatic operation.
The Automatic operation will be activated immediately once the Auto operation button is pressed. However, temperature cannot be adjusted in this operation.
The power indicator on the indoor unit will blink until the operation mode is selected automatically.
To cancel this operation, press this button once more.
Remote Control Signal Receiving Sound
AUTO
ON
To switch off the beep (Signal Receiving Sound), press the Auto Operation button for 10 seconds continuously or longer.
Repeat the above steps if you want to switch on the Signal Receiving Sound.
Timer Setting
When power failure occurs, the timer setting will be
cancelled. Once power is resumed, reset the timer.
5 seconds
AUTO TEST RUN SOUND
1 Beep
10 seconds
2 Beep
ENGLISH
ENERGY SAVING AND OPERATION HINTS
Setting the Temperature
Set the temperature higher or lower than the
desired temperature.
Cooling Operation : 1˚C higher Heating Operation : 2˚C lower Approximately 10% of electricity can be saved.
Air Filters
Clean the air filters every 2 weeks.
Dirty filters may reduces cooling or heating
efficiency.
Keep All Doors and Windows Closed
Otherwise, cooling or heating performance will be
reduced and electricity cost is wasted.
Outdoor Unit
Do not block the air outlet vent. Otherwise, it will
lower the cooling or heating performance.
Avoid Direct Sunlight
Keep curtains or drapes closed to avoid direct
sunlight during cooling operation.
F563553/01-08/EN 5/6/02, 10:34 am7
Thunder and Lightning
This air conditioner is equipped with a built-in
surge protective device. However, in order to further protect your air conditioner from being damaged by abnormally strong lightning activity, you may switch off the main power supply and unplug from power socket.
6
TROUBLE SHOOTING
Normal Operation
Is it okay? This is the answer
Air conditioner has been restarted, but does not operate for 3 minutes.
A sound like water flowing can be heard.
It seems that fog is coming out from the air
conditioner.
The room has a peculiar odour.
During Automatic Fan speed, indoor fan stops
occasionally.
The outdoor unit emits water or steam.
Operation stops for about 12 minutes during
heating operation (The power indicator blinks).
During heating operation, indoor fan may run at on and off conditions.
This is to protect the air conditioner. Wait until the air conditioner begins to operate.
This is the sound of refrigerant flowing inside the air conditioner.
Condensation occurs when the airflow from the air conditioner cools the room.
This may be a damp smell emitted by the wall, carpet, furniture or clothing in the room.
This is to remove smell emitted by the surroundings.
In COOL/DRY operation, moisture in the air condenses
into water on the cool surface of outdoor unit piping that causes dripping.
This is to melt the frost which has accumulated on the outdoor unit (defrosting operating). This will take no longer than about 12 minutes. Water drips from the outdoor unit. Wait until this operation ends. (The power indicator will light up). (Frost will accumulates on the outdoor unit when the outdoor temperature is low and humidity is high.)
This is to prevent undesired cooling effect during heating operation.
Call The Dealer Immediately
If the following conditions occur, turn off and unplug the main power supply, and then call the dealer immediately.
Abnormal noise is heard during operation.
Water or foreign material gets into the remote
control by mistake.
Water leaks from the indoor unit.
Switches or buttons do not operate properly.
The circuit breaker switches off frequently.
Power supply cord and plug become unusually
warm.
Abnormal Operation
The air conditioner does not operate.
Air conditioner produces loud noise during
operation.
The air conditioner does not cool or warm
effectively.
7
F563553/01-08/EN 5/6/02, 10:34 am8
Is it okay? Please check
Has the circuit breaker been tripped?
Has the power plug been removed from the wall outlet?
Is the timer being used correctly?
Is the installation work slanted?
Is the front grille closed properly?
Has the temperature been set incorrectly?
Are the filters dirty?
Are the intake or outlet vents of the outdoor unit
obstructed?
Are all windows and doors closed?
EV ALUATION OF THE PERFORMANCE
WARNING
ENGLISH
Operate the unit for 15 minutes or more;
Measure the temperature of the intake and outlet air;
The temperature difference is more than 8˚C during
Cooling operation or more than 14°C during Heating operation.
If the unit fulfils the above conditions, the unit is in normal operation.
Air intake vent
Thermometer
Air outlet vent
Use this air conditioner under the following conditions:
Unit in ˚C
DBT: Dry Bulb Temp. WBT: Wet Bulb T emp.
Maximum T emperature – Cooling 32 23 43 26 (Maximum T emperature – Heating) (30) (–) (24) (18)
Minimum T emperature – Cooling 16 11 16 11 (Minimum Temperature – Heating) (2) (–)(–5) (–6)
Indoor Outdoor
DBT WBT DBT WBT
1) This appliance must be earthed.
2) If the supply cord is damaged or need to be replaced, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
3) Remove power plug or disconnect from the mains before servicing this appliance.
4) Do not repair by yourself .
In case of malfunction of this appliance, do not repair by yourself. Contact to the sales dealer or service dealer for a repair.
5) Do not use in an explosive atmosphere.
Do not use this appliance in a potentially explosive atmosphere.
6) Disconnect the power plug (isolation from main power supply).
Disconnect the power plug from the receptacle, or switch off the breaker, or switch off the power, disconnecting mains plug to isolate the equipment from the main power supply in case of an emergency.
CAUTION
DISCONNECT THE MAINS PLUG FROM THE SUPPLY SOCKET WHEN NOT IN USE , WHERE SUPPLY CONNECTION IS VIA MAINS PLUG.
Airborne noise :
A-weighted sound pressure level of this appliance is less than 70dB(A) under the JIS C 9612 test conditions. Maximum cooling operation 1 m from the unit
IMPORTANT
The wires in this mains lead are coloured in accordance with the following code :
Green and Y ellow : Earth Blue : Neutral Brown : Live
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
F563553/01-08/EN 5/6/02, 10:34 am9
The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked by the letter E or by safety earth symbol
The wire which is coloured blue must be connected to the terminal which is marked with letter N or coloured black. The wire which is coloured brown must be connected to the terminal which is marked with letter L or coloured red.
or coloured green or green and yellow.
8
d
l
Not
e
g:
e
chased
e
bli
:
deu
a
:
odel
t
a
g
:
Aankoopdatu
a
odef
s
t
a
g
:
Nr
a
t
odello
ie
e
a
06-
:
ease remember to record the followin
Number
rial Number
r
Nam
Pur
Remarqu
ou
ez pas de noter les informations suivantes
m du reven
Not
registar os dados seguintes
mero de m
mero de representan
ata de compr
Anmerkun
Bitte notieren Sie die folganden Daten
-
rien-Nr
Opmerkin
vergeet niet volgende zaken te noteren
nummer
rienummer
rnummer
Not
cordare di trascrivere i aeguentl da
ice m
mero di ser
ice rivenditor
ata di acquisto
Not
o se olvide de registrar los datos siguientes
mero de m
el representan
echa de compr
Matsushita Electric Industrial Co.,Lt
eb Site:http://www.panasonlc.co.jp/globa
F563553/01-08/EN 5/6/02, 10:34 am10
Printed in Chin
P02
Loading...