Panasonic CU-S9PKR, CS-S12PKR, CS-S24PKR, CU-S12PKR, CU-S18PKR Operating Instructions Manual

...
Page 1
English
Model No. Indoor Unit Outdoor Unit
CS-S9PKR CS-S12PKR CS-S18PKR CS-S24PKR CS-S28PKR
CU-S9PKR CU-S12PKR CU-S18PKR CU-S24PKR CU-S28PKR
Air Conditioner
F569363
Operating Instructions Air Conditioner
Thank you for purchasing Panasonic Air Conditioner. Installation instructions attached. Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Page 2
2
Quick guide
Inserting the batteries
1
Pull out the back cover of remote control
2
Insert AAA or R03 batteries (can be used ~ 1 year)
3
Close the cover
Clock setting
1
Press CLOCK
2
Set the time
3
Confi rm
Basic operation
1
Select the desired mode
FAN
AUTO COOL
DRY
2
Start/stop the operation
POWER
• Please note that the OFF indication is on to start.
3
Select the desired temperature
• Selection range: 16 °C ~ 30 °C (Not applicable for FAN mode).
• Operating the unit within the recommended temperature may save energy. COOL: 26 °C ~ 28 °C. DRY : 1 °C ~ 2 °C lower than room
temperature.
•
The set temperature selection range can be customized according to requirement. Please consult authorised dealer.
• To dim or restore the unit’s indicator brightness, press and hold for 5 seconds.
• Use remote control within 8 m from the remote control
receiver of the indoor unit.
The illustrations in this manual are for explanation purposes only and may differ from the actual unit. They are subject to change without notice for future improvement.
Page 3
3
English
Table of contents
Safety precautions ................................4-5
How to use............................................6-7
To learn more... ...................................... 8
Cleaning instructions ............................... 9
Troubleshooting .................................... 10
Information............................................. 11
Accessories
• Remote control
• AAA or R03 batteries × 2
• Remote control holder
• Screws for remote control holder × 2
1
2
3
ON
OFF
SET
CANCEL
TIMER
123
SET CHECK CLOCK RESET
AC RC
ON
O
FF
CANCEL
TIMER
1
3
S
ETCHE
CK
RES
ET
A
C
RC
2 3
1
MODE
ON
OFF
SET
CANCEL
TIMER
POWERFUL
FAN SPEED
ECONOMY
123
SET CHECK CLOCK RESET
AC RC
MODE
AIR CONDITIONER
OFF/ON
AIR SWING
ON
OFFS
ET
CANCEL
TIMER
POWERFU
L
FAN SPEE
D
ECONOMY
1
2
3
S
ETCHE
CK
CLOCK
RES
ET
A
C
RC
MO
DE
A
IR CONDITIONE
R
AIR SWIN
G
1
2
3
S9PKR, S12PKR S18PKR, S24PKR,
S28PKR
MODE
ON
OFF
SET
CANCEL
TIMER
POWERFUL AIR SWING
FAN SPEED
ECONOMY
123
SET CHECK CLOCK RESET
AC RC
MODE
AIR CONDITIONER
OFF/ON
ON
OFFS
ET
CANCEL
TIMER
POWERFU
L
A
IR SWIN
G
F
AN SPEE
D
ECONOM
Y
1
2
3
S
ETCHECKCLOC
K
RES
ET
AC
RC
MODE
A
IR CONDITIONE
R
1
2
3
8m
Page 4
4
Safety precautions
To prevent personal injury, injury to others or property damage, please comply with the following: Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to property.
The instructions to be followed are classifi ed by the following symbols:
This symbol denotes an action that is PROHIBITED.
These symbols denote actions COMPULSORY.
WARNING
Indoor unit and outdoor unit
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Please consult authorised dealer or specialist to clean the internal parts, repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fi re.
Confi rm with authorised dealer or specialist on usage of any specifi ed refrigerant type. Using refrigerant type other than the specifi ed may cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive or fl ammable atmosphere. Failure to do so could result in fi re.
Do not insert your fi ngers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it may cause electric shock.
Do not expose yourself directly to cold air for a long period to avoid excess cooling.
Do not sit or step on the unit, you may fall down accidentally.
Remote control
Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries.
Power supply
Do not use a modifi ed cord, joint cord, extension cord or unspecifi ed cord to prevent overheating and fi re.
Indoor unit
Outdoor unit
Power supply
Remote control
Air inlet
Air inlet
Air inlet
Air inlet
Air outlet
Air outlet
Air outlet
Air outlet
Page 5
5
English
Safety precautions
To prevent overheating, fi re or electric shock:
•
Do not share the same power outlet with other equipment.
•
Do not operate with wet hands.
•
Do not over bend the power supply cord.
•
Do not operate or stop the unit by inserting or pulling out the power plug.
If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualifi ed persons in order to avoid a hazard.
It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fi re.
To prevent overheating, fi re or electric shock:
•
Insert the power plug properly.
•
Dust on the power plug should be periodically wiped with a dry cloth.
Stop using the product if any abnormality/failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fi re/electric shock) Examples of abnormality/failure
•
The ELCB trips frequently.
•
Burning smell is observed.
•
Abnormal noise or vibration of the unit is observed.
•
Water leaks from the indoor unit.
•
Power cord or plug becomes abnormally hot.
•
Fan speed cannot be controlled.
•
The unit stops running immediately even if it is switched on for operation.
•
The fan does not stop even if the operation is
stopped. Contact your local dealer immediately for maintenance/repair.
This equipment must be earthed to prevent electrical shock or fi re.
Prevent electric shock by switching off the power supply and unplug:
- Before cleaning or servicing,
- When extended non-use, or
- During abnormally strong lightning activity.
CAUTION
Indoor unit and outdoor unit
Do not wash the indoor unit with water, benzine, thinner or scouring powder to avoid damage or corrosion at the unit.
Do not use for preservation of precise equipment, food, animals, plants, artwork or other objects. This may cause quality deterioration, etc.
Do not use any combustible equipment in front of the airfl ow outlet to avoid fi re propagation.
Do not expose plants or pet directly to airfl ow to avoid injury, etc.
Do not touch the sharp aluminium fi n, sharp parts may cause injury.
Do not switch ON the indoor unit when waxing the fl oor. After waxing, aerate the room properly before operating the unit.
Do not install the unit in oily and smoky areas to prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to avoid injury.
Do not step onto an unstable bench when cleaning the unit to avoid injury.
Do not place a vase or water container on the unit. Water may enter the unit and degrade the insulation. This may cause an electric shock.
Do not open window or door for long time during COOL/DRY mode operation.
Prevent water leakage by ensuring drainage pipe is:
- Connected properly,
- Kept clear of gutters and containers, or
- Not immersed in water
After a long period of use or use with any combustible equipment, aerate the room regularly.
After a long period of use, make sure the installation rack does not deteriorate to prevent the unit from falling down.
Remote control
Do not use rechargeable (Ni-Cd) batteries. It may damage the remote control.
To prevent malfunction or damage of the remote control:
•
Remove the batteries if the unit is not going to be used for a long period of time.
•
New batteries of the same type must be inserted following the polarity stated.
Power supply
Do not disconnect the plug by pulling the cord to prevent electric shock.
Page 6
MODE
ON
OFF
SET
CANCEL
TIMER
POWERFUL AIR SWING
FAN SPEED
ECONOMY
123
SET CHECK CLOCK RESET
AC RC
MODE
AIR CONDITIONER
OFF/ON
ON
O
FF
S
ET
CANCEL
TIMER
HECKCLOC
K
FF/
ON
6
How to use
To adjust horizontal airfl ow direction
(9PKR, S12PKR)
• Manually adjustable.
Auto OFF/ON button
Use when remote control is misplaced or a malfunction occurs. Raise the front panel:
• To use in AUTO mode, press the button once.
• To use in COOL mode, press and hold the button until 1 beep is heard, then release.
• Press the button again to turn off.
S9PKR, S12PKR
S18PKR, S24PKR, S28PKR
MODE
To select operation mode
AUTO - For your convenience COOL - To enjoy cool air DRY - To dehumidify the environment FAN - To circulate air in the room
POWERFUL
To reach temperature quickly
POWERFUL
• This operation will stop automatically after 20 minutes.
To enjoy quiet operation
QUIET/ECONOMY
• This operation reduces airfl ow noise.
FAN SPEED
To select fan speed
(Remote control display)
• For AUTO, the indoor fan speed is automatically adjusted according to the operation mode.
Indicator
POWER
TIMER
QUIET/ECONOMY
POWERFUL
(Green) (Orange) (Orange) (Orange)
Press and hold for approximately 10 seconds to show temperature setting in °C or °F.
Press to restore the remote control to default setting.
Not used in normal operations.
Remote control display
POWERFUL
FAN SPEED
AIR SWING
Page 7
7
English
How to use
ECONOMY
To save electrical power consumption
QUIET/ECONOMY
• Save power consumption at unoccupied room by adjust set temperature up to 3°C automatically.
• Brightness of all indicators will be dimmed.
AIR SWING
To adjust vertical airfl ow direction
(S9PKR, S12PKR)
(Remote control display)
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver swings up/down automatically.
• Do not adjust the louver by hand.
AIR SWING
To adjust airfl ow direction
(S18PKR, S24PKR, S28PKR)
(Remote control display)
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver swings left/right and up/down automatically.
• Do not adjust the louver by hand.
Note
,
POWERFUL
,
ECONOMY
• Can be activated in all modes and can be cancelled by pressing the respective button again.
• Cannot be selected at the same time.
To set the timer
2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset times.
ON
OFF
SET
CANCEL
TIMER
123
ANCE
L
1 2 3
1
Select ON or OFF timer Example:
OFF at 22:00
• Each time pressed:
OFF
Cancel
2
Set the time
2
3
Confi rm
SET
TIMER
• To cancel ON or OFF timer, press
ON
or
OFF
to
select respective or then press
CANCEL
.
• If timer is cancelled manually or due to power failure, you can restore the timer again by
pressing
ON
or
OFF
to select respective or
then press
SET
.
• The nearest timer setting will be displayed and will activate in sequence.
• When ON Timer is set, the unit may start earlier (up to 15 minutes) before the actual set time in order to achieve the desired temperature on time.
• Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Quick guide.
Page 8
8
To learn more...
Operation mode
AUTO : During operation mode selection the POWER indicator blinks.
• Unit selects operation mode during startup according to setting temperature and room temperature.
COOL : Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL
mode.
DRY : Unit operates at low fan speed to give a gentle cooling operation. FAN : To circulate air in the room
Operation conditions
Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature WBT : Wet bulb temperature
Temperature (°C)
Indoor Outdoor
DBT WBT DBT WBT
COOL
Max. 32 23 46 26
Min. 16 11 5 4
Page 9
9
English
POWER
TIMER
QUIET/ECONOMY
POWERFUL
Cleaning instructions
To ensure optimal performance of the unit, cleaning has to be carried out at regular intervals. Dirty unit may cause malfunction and you may see error code “H99”. Please consult authorised dealer.
• Switch off the power supply and unplug before cleaning.
• Do not touch the aluminium fi n, sharp parts may cause injury.
• Do not use benzine, thinner or scouring powder.
• Use only soap (
pH 7) or neutral household
detergent.
• Do not use water hotter than 40 °C.
Indoor unit
Wipe the unit gently with a soft, dry cloth.
Front panel
Wash gently and dry.
Remove the front panel
POWER
TIMER
QUIET/ECONOMY
POWERFUL
Raise
Pull out
1
2
Close it securely
For CS-S18PKR, CS-S24PKR, CS-S28PKR: Press at center of the front panel.
4
POWER
TIMER
QUIET/ECONOMY
POWERFUL
Insert at both sides
1
Press both ends of the front panel
3
Close down
2
Air fi lters
Every 2 weeks
• Wash/rinse the fi lters gently with water to avoid damage to the fi lter surface.
• Dry the fi lters thoroughly under shade, away from fi re or direct sunlight.
• Replace any damaged fi lters.
Remove air fi lter Attach air fi lter
Insert into the unit
Anti-bacterial fi lter
Anti-bacterial fi lter.
• Clean the fi lter whenever necessary.
• Wash/rinse the fi lter gently with water to avoid damage to the fi lter.
• Dry the fi lter thoroughly under the shade, away from fi re or direct sunlight.
• Replace the fi lter every 10 years or replace any damaged fi lter. Part no.: CZ-SA22P
For seasonal inspection after extended non-use
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• Use Auto OFF/ON button to select COOL
operation. After 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents:
COOL: ≥ 8 °C
For extended non-use
• Turn off the power supply and unplug.
• Remove the remote control batteries.
Aluminium fi nFront panel
Indoor unit
Anti-bacterial fi lter
Air fi lters
To learn more... / Cleaning instructions
Page 10
10
The following symptoms do not indicate malfunction.
Symptom Cause
Mist emerges from indoor unit. • Condensation effect due to cooling process. Water fl owing sound during operation. • Refrigerant fl ow inside the unit.
The room has a peculiar odour. • This may be due to damp smell emitted by the wall,
carpet, furniture or clothing.
Indoor fan stops occasionally during automatic fan speed setting.
• This helps to remove the surrounding odour.
Operation is delayed a few minutes after restarting.
• The delay is a protection to the unit’s compressor.
Outdoor unit emits water/steam. • Condensation or evaporation occurs on pipes. TIMER indicator is always on. • The timer setting repeats daily once set. POWER indicator blinks before the unit is
switched on.
• This is a preliminary step in preparation for the operation when the ON timer has been set.
Cracking sound during operation. • Changes of temperature caused the expansion/
contraction of the unit.
POWER indicator blinks 3 seconds ON and
0.5 seconds OFF during operation.
• The unit is in Demand Response Mode.
Check the following before calling for servicing.
Symptom Check
Operation in COOL mode is not working effi ciently.
• Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the fi lters.
•
Clear any obstruction at the air inlet and air outlet vents.
Noisy during operation. • Check if the unit has been installed at an incline.
• Close the front panel properly.
Remote control does not work. (Display is dim or transmission signal is weak.)
• Insert the batteries correctly.
• Replace weak batteries.
The unit does not work. • Check if the circuit breaker is tripped.
• Check if timers have been set.
The unit does not receive the signal from the remote control.
• Make sure the receiver is not obstructed.
• Certain fl uorescent lights may interfere with signal transmitter. Please consult authorised dealer.
Troubleshooting
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY AND UNPLUG then please consult authorised dealer under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
The unit stops and the TIMER indicator blinks.
Use remote control to retrieve error code.
ON
OFF
SET
CANCEL
TIMER
123
SET CHECK CLOCK RESET
AC RC
FF
ET
ANCE
L
ET CLOCKESET
Press for 5 seconds
Press for 5 seconds to quit checking
Press until you hear beep sound, then write down the error code
Turn the unit off and reveal the error code to authorised dealer
21
3
4
•
For certain errors, you may restart the unit for limited operation with 4 beeps when operation starts.
Page 11
11
English
Troubleshooting / Information
Information
English
Information for Users on Collection and Disposal of Old Equipment and used Batteries
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.
Pb
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved.
Page 12
F569363
SA0413-0
Printed in Malaysia
Panasonic Corporation
Website: http://panasonic.net/
© Panasonic Corporation 2013
Loading...