-35-
5. Auto Gain Up Control Setting
[Auto Gain Up: OFF, ON]
This cannot be set when “Auto” has been set for the
CCD storage time setting (1-9).
OFF: The light quantity is not adjusted
automatically.
ON: The light quantity is adjusted automatically.
The maximum to which the gain can be
increased using the auto gain up function is
selected by the AGC maximum gain setting (1-6).
6. AGC Maximum Gain
[AGC Max Gain: 6dB, 12dB, 18dB, 24dB, N/Eye L,
N/Eye H] (AW-E750, AW-E655, AW-E650)
[AGC Max Gain: 6dB, 12dB, 18dB, 24dB, N/Eye]
(AW-E350)
This is used to set the maximum amount to which the
gain can be increased when “ON” has been selected
as the auto gain up setting (1-5).
7. Manual Gain Up Control Setting
[Manual Gain Up: 0 dB to 30 dB, N/Eye L, N/Eye H]
(AW-E750, AW-E655, AW-E650)
[Manual Gain Up: 0 dB to 30 dB, N/Eye] (AW-E350)
Manual setting is possible only when the Auto Gain
Up control (1-5) is in the OFF position.
0 dB: 0 dB should be selected in normal cases.
1 dB to 30 dB: Use this range if sufficient video out-
put cannot be obtained even when the lens iris is
opened in shooting dark scenes.
AW-E750, AW-E655, AW-E650
Night Eye L: Use this setting if it is not possible to
achieve a satisfactory video output even at 30 dB.
Night Eye H: Use this setting if it is not possible to
achieve a satisfactory video output even at the
Night Eye L setting.
AW-E350
Night Eye: Use this setting if it is not possible to
achieve a satisfactory video output even at 30 dB.
• In case of settings on the camera alone or when
the iris switch on the RCU (RCB) is at [AUTO], the
Auto Gain Up control may not operate if the lens
iris switch is in the manual position.
• When the AGC switch on the hybrid control panel
is set to AGC, the Auto Gain Up control operates
in the HIGH position.
Notes
Hybrid Control Panel
AGC Switch