Panasonic AW-AD700BS User Manual

Camera Adaptor
AW-AD700BS
for AW-F575 Series
Before attempting to connect or operate this product, please read
these instructions completely.
WARNING:
TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
SA 1965
SA 1966
PREF ACE
• The Camera Adaptor AW-AD700BS docks directly to the Color Camera AW-F575 series, making it a standard-alone camera for two-piece recording system applications. Connection via a VTR cable for several different portable recorder is possible.
NOTE: Refer to the operating instructions of Color Camera AW-F575 series for details.
The exclamation point within an equilat­eral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appli­ance.
Warning: This equipment generates and uses radio frequency energy and if not installed and used properly, i.e., in strict accordance with the instruction manual, may cause harmful interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment.
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
The serial number of this product may be found on the bottom of the unit. You should note the serial number of this unit in the space provided and retain this book as a permanent record of your purchase to aid identification in the event of theft.
Model No. Serial No.
For U.S.A
For CANADA
• Video Power (VP) Multiplex Operation is available using with the Power Separator WV-PS700.
• Possible to mount a lens having zoom, focus or servo functions.
• Pan/Tilt Control function is provided.
-2-

MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS

!2
+ 1
VTR MULTI
MPX
CABLE
SEL
20
60(dB)
AUDIO LEVEL
INT
PB
EARPHONE
OUT SEL
VTR
TRIGGER
ENC
Y/PR/PB
RCU/VTR
SIGNAL
Y/C/B R/G/B
- 1
+ 2
!1 !0 o i
@4
!6
!7
!8
!9
@0
!5 !3
!4
@3
@2
@1
q w
e
r t
y u
1. Camera Handle
2. Camera Adaptor Holding Screw/knob
The camera adaptor can be removed from the camera after loosening two knobs on top of the adaptor and then pressing the release button underneath of the camera while pulling on rear of camera adaptor.
3. VTR Start/Stop Button (VTR) (parallel operation)
This button is used to change the recorder mode from pause (Recording Pause) to recording and functions in the same way as the VTR Start/Stop Button on the lens. Press once to start recording. While recording, the Tally Indicator in the viewfind­er lights and Tally Light on the viewfinder also lights. When the button is pressed once more, the recorder is set to the Pause mode (Recording Pause), and the Recording/Tally Indicator and Tally Light will go off.
4. Intercom/Earphone Level Control (INCOM EARPHONE)
Use this control to freely adjust the volume level in the earphone connected to the Earphone Jack (7) or the headset connected to the Intercom Jack (6).
5. S-Video Output Connector (S-VIDEO OUT)
The luminance (Y) and chroma (C) signals for S­VHS VTR or monitor are provided at this connector.
6. Intercom Jack (M6) (INCOM)
This jack is used for communication between the camera operator and operators of Remote Control Unit (RCU) and Special Effect Generator in the sys­tem.
7. Earphone Jack (M3) (EARPHONE)
When an earphone is connected, the sound picked up by the microphone or the played back audio from a 3/4” U-vision recorder, connected to the camera through the VTR 14-pin camera connector, can be monitored. Selection of the audio source is enabled by the Earphone Out Selection Switch (10).
8. RCU/VTR Signal Selection Switch (RCU/VTR SIGNAL ENC, Y/C/B, R/G/B, Y/PR/PB)
This switch selects the video output signal supplied at the VTR/RCU Connector (18) on the adaptor and the Red, Green and Blue Output Connectors on the Remote Control Unit (RCU). The switch has been set to the R/G/B position at the factory.
ENC:
The composite output signal for the VTR, such as 1/2” VHS or 3/4” U Machic, is supplied.
Y/C/B:
The chrominance (C) and luminance (Y) sig­nals are supplied from the R, G and B Output Connectors for S-VHS format VTR.
-3-
R/G/B:
The R, G and B signals are supplied from the R, G and B Output Connector.
Y/PR/PB:
The color difference (R-Y & B-Y) signals and luminance (Y) signal are supplied from the VTR/RCU Connector (18) and the R, G and B Output Connectors on the Remote Control Unit for MII and Betacam format VTRs.
9. VTR Compatibility Switch (!1/!2/@1)
Set this switch according to the VTR which is con­nected to the camera.
!1: For 1/2” VHS VTRs. !2: For 3/4” U-vision VTRs, connected to the cam-
era using a 14-pin connector, S-VHS VTRs and MII portable VTRs.
@1: If a VTR of other manufacture is used, and if
this VTR pauses when the tape should be run­ning and vice versa, this switch should be set to this position.
Notes:
1) The switch has been preset to the !1 position at the factory.
2) Some VTRs may not operate properly when connected to this camera, even though the set­ting of this switch is changed. Please consult your dealer for further information.
10. Earphone Out Selection Switch (INT/PB)
This switch selects the audio signal from the Earphone Jack (7) to be monitored.
INT:
The sound picked up by the microphone can be monitored.
PB:
The played back audio can be monitored.
Note:
The camera has been preset to the INT posi­tion at the factory.
11. Audio Level Selection Switch (AUDIO LEVEL –20/–60 dB)
Two audio output levels to the VTR can be select­ed: –20 dB or –60 dB The camera has been preset to –20 dB at the facto­ry. When using this adaptor with WV-RC700A, set this switch to the –20 dB position.
12. Cable Selection Switch (VTR MULTI/MPX)
This switch is used to select either the multi-cable VTR/RCU cable or the single coaxial multiplex cable. When using the multi-cable in the VTR or Remote Control Unit (RCU), set this switch to VTR MULTI position. In case of the multiplex or VP multi­plex operation using a coaxial cable, set this switch to MPX position.
Note:
Video Power (VP) Multiplex system: multiplex signal and power are supplied using a single coaxial cable.
13. Video Output Connector (BNC) (VIDEO OUT)
A composite video signal is provided at this con­nector.
14. Gen-lock input connector (BNC) (GEN-LOCK)
The color video signal of the camera is automatical­ly synchronized to the Gen-lock signal (composite or black burst) which is supplied to this connector. The gen-lock signal is used for system reference, such as when using a Special Effects Generator.
Caution:
If the gen-lock signal is jittery (such as when obtained from VTR playback), the camera may not be able to synchronize properly.
15. Multiplex Signal input Connector (MPX)
Communications between the camera side and the Remote Control Unit (RCU) are available through a single coaxial cable by using this connector as the composite signal, gen-lock signal, control signal and intercom/audio signal are multiplexed, and the composite signal is output from the Remote control Unit (RCU).
16. External DC Input Connector (XLR, 4-pin) (EXT DC)
This connector accepts the power cable from an external DC source supplying nominal power of 12 V, 2 A (a belt type battery or car battery for example). This connector also accepts the power cable from an AC adaptor. For powering the studio configuration, a 12 V DC, 2.5 A power source is required.
Cautions:
Use only with a 12V DC power source with a Class 2 rating. Do not use with an external stor­age battery unless provided with an 8A rated fuse, located within 5 inches of the battery con­necting means. An eternal DC source supplied to this connec­tor gets the highest priority, i.e., it is selected before the battery connector or Multicore/ VTR/DC source.
17. Circuit Protector (BREAKER)
When excessive current flows into the camera due to some fault, the red button of this circuit protector protrudes to cut off the circuit power. After solving the problem, press the red button again to reset the circuit protector.
Caution:
Refer servicing to qualified service personnel to solve the problem.
18. VTR/RCU Connector (26-pin) (VTR/RCU)
When using the camera together with a Panasonic portable color VTR, the specified VTR Cable should be connected between the camera and VTR. This connector is also used for connection with the 26­pin studio cable from the Remote Control Unit (RCU) for comprehensive system operation. When connecting the 26-pin studio cable to this connec­tor, the camera is automatically set to the Remote Control Unit (RCU) operation mode.
• 1/2” VHS and 3/4” U-vision portable VTR (10­pin) WV-CA26A10 (26p-10p cable) 3/4” U-vision portable VTR (14-pin) WV-CA26A14 (26p-14p cable)