Panasonic AQ-C Relays, AQCD3-M, AQCD3-IM, AQC1A1, AQC1A2 Specification Sheet

...
AQ-C
ORDERING INFORMATION
TYPES
1. Input module
Standard packing: Carton: 50 pcs.; Case: 500 pcs.
Miniature DIL 1A control
type for PCBs
Type Output voltage Input voltage Part No. AC input 4 to 32 V DC 80 to 250 V AC AQCD3-IM 100/240 V AC DC input 4 to 32 V DC 3 to 32 V DC AQCD3-IM 4/24 V DC
Please contact us about TÜV certified products.
Compliance with RoHS Directive
FEATURES
• Compact DIL type: L20 mm × W10 mm × H12.8 mm
(.787×.394×.504 inch)
• Excellent in noise resistance
•Snubber circuit integrated
• High dielectric strength: 2,500 V between input and output
•Reverse polarity type available
TYPICAL APPLICATIONS
• Compact AC motor, Solenoid, Magnet, Driver of magnetic valve
• Copying equipment
• NC machine, Robot
•Programmable controller
• Air conditioners
Load current Nil: 1A:
AQC
Load voltage 1: 2: D1: D3:
Type Nil: IM: T: ZT:
Input voltage Output module: Input module:
5, 12, 24 V DC 4/24 V DC, 100/240 V AC
Input polarity Nil: R:
Input module Output module
75 to 125 V AC (Output module) 75 to 250 V AC (Output module) 3 to 60 V DC (Output module) 4 to 32 V DC (Input module)
DC output Input module AC output Random AC output Zero-cross
Standard polarity Reverse polarity (Only for output module)
All Rights Reserved © C
OPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-C
2. Output module
Standard packing: Carton: 50 pcs.; Case: 500 pcs. Note: Reverse polarity type (AQC5∗∗ and AQC6∗∗) is also produced by lot after receipt of order.
SPECIFICATIONS
Rating [at 20°C 68°F; Input voltage ripple (output module) and output voltage ripple (input module): max. 1%]
1. Input module
2. Output module
(1) AC output type
(2) DC output type
Notes: *1. Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
*2. Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”. *3. Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”. *4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
Type Load voltage Input voltage Part No.
AC output Zero-cross
75 to 125 V AC
5 V DC AQC1A1 - ZT5 V DC 12 V DC AQC1A1 - ZT12 V DC 24 V DC AQC1A1 - ZT24 V DC
75 to 250 V AC
5 V DC AQC1A2 - ZT5 V DC 12 V DC AQC1A2 - ZT12 V DC 24 V DC AQC1A2 - ZT24 V DC
AC output Random
75 to 125 V AC
5 V DC AQC1A1 - T 5 V DC 12 V DC AQC1A1 - T 12 V DC 24 V DC AQC1A1 - T 24 V DC
75 to 250 V AC
5 V DC AQC1A2 - T 5 V DC 12 V DC AQC1A2 - T 12 V DC 24 V DC AQC1A2 - T 24 V DC
DC output 3 to 60 V DC
5 V DC AQC1AD1- 5 V DC 12 V DC AQC1AD1- 12 V DC 24 V DC AQC1AD1- 24 V DC
Type
Item
AC input DC input
Remarks
AQCD3-M 100/240 V AC AQCD3-IM 4/24 V DC
Input side
Input voltage 80 to 250 V AC 3 to 32 V DC Input current Max. 5 mA Max. 5 mA Pick-up voltage Max. 80 V AC Max. 3 V DC Drop-out voltage Min. 10 V AC Min. 1 V DC
Output side
Load voltage 4 to 32 V DC 4 to 32 V DC Load current 0.1 to 25 mA 0.1 to 25 mA Max. “OFF-state” leakage current Max. 5µA Max. 5µA When 32 V DC applied Max. “ON-state” voltage drop Max. 1.6 V Max. 1.6 V at max. carrying current
Type
Item
AQC1A1-
ZT5VDC
AQC1A1-
T5VDC
AQC1A1­ZT12VDC AQC1A1-
T12VDC
AQC1A1­ZT24VDC AQC1A1-
T24VDC
AQC1A2-
ZT5VDC
AQC1A2-
T5VDC
AQC1A2­ZT12VDC AQC1A2-
T12VDC
AQC1A2­ZT24VDC AQC1A2-
T24VDC
Remarks
Input side
Input voltage
(5 V type)
4 to 6 V DC
(12 V type)
9.6 to 14.4 V DC
(24 V type)
21.6 to 26.4 V DC
(5 V type)
4 to 6 V DC
(12 V type)
9.6 to 14.4 V DC
(24 V type)
21.6 to 26.4 V DC
*
3
Input impedance (Approx.) 0.3 k 0.8 k 1.8 k 0.3 k 0.8 k 1.8 k Drop-out voltage, min 0.5 V 1.2 V 2.4 V 0.5 V 1.2 V 2.4 V
Load side
Max. load current 1 A*
1
Ta = Max. 40°C 104°F Load voltage 75 to 125 V AC 75 to 250 V AC Non-repetitive surge current 20 A*
2
In one cycle at 60 Hz Max. “OFF-state” leakage current 0.6 m A (When 100 V AC applied) 1.1 m A (When 200 V AC applied) at 60 Hz Max. “ON-state” voltage drop 1.6 A at max. carrying current Min. load current 10 mA*
4
20 mA*
4
Type
Item
AQC1AD1-5VDC AQC1AD1-12VDC AQC1AD1-24VDC Remarks
Input side
Input voltage
(5 V type)
4 to 6 V DC
(12 V type)
9.6 to 14.4 V DC
(24 V type)
21.6 to 26.4 V DC *
3
Input impedance (Approx.) 0.43 k 1.2 k 2.8 k Drop-out voltage, min 0.8 V
Load side
Max. load current 1 A*
1
Ta = Max. 40°C 104°F
Load voltage 3 to 60 V DC Non-repetitive surge current 1.5 A*
2
at 1s
Max. “OFF-state” leakage current 0.1 m A (When 60 V DC applied) Max. “ON-state” voltage drop 1.6 V at max. carrying current Min. load current 1 mA*
4