Panasonic ALD14H, ALD105, ALD106, ALD109, ALD112 Specifications

...
Page 1
LD (ALD)
SPECIFICATIONS
1 FORM A
SLIM POWER RELAY
LD RELAYS (ALD)
VDE
15.0
.591
20.3
.799
.276
mm inch
RoHS Directive compatibility information
http://www.nais-e.com/
FEATURES
1. Slim type: Width 7 mm .276 inch.
20.3(L)×7.0(W)×15.0(H) mm
.799(L)×.276(W)×.591(H) inch
2. Perfect for small load switching of home appliances
10
5
switching operations possible with a
3A 250V AC resistive load.
3. Low operating power
Compact size, nominal operating power as low as 200mW.
4. High shock resistance
The relay withstands a functional shock resistance of 300m/s
2
[approx. 30 G
more]
5. High insulation resistance
• Creepage distance and clearances between contact and coil: Min. 6 mm .236
inch (In compliance with IEC65)
• Surge withstand voltage between contact and coil: 10,000 V or more.
6. UL/CSA, VDE, TÜV approved.
Contact
Coil
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the actual load.
Remarks
* Specifications will vary with foreign standards certification ratings. *
1
Measurement at same location as “Initial breakdown voltage” section.
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of ±1.2×50ms according to JEC-212-1981
*
4
Excluding contact bounce time.
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10 µs
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10 µs
*
8
Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT
Characteristics
Arrangement 1 Form A Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Max. 100 m
Contact material AgSnO2 type
Rating (resistive load)
Nominal switching capacity
3 A 277 V AC,
3 A 30V DC
Max. switching power
831 V A (AC),
90W (DC) Max. switching voltage 277 V AC, 30 V DC Max. switching current 3 A Min. switching capacity
#1
100 mA, 5 V DC
Expected life (min.operations)
Mechanical (at 180 cpm) 5×10
6
Electrical (at 20 cpm) (at rated load)
3A 125V AC, 3A 30V DC
2×10
5
3A 250V AC 10
5
Nominal operating power 200 mW
Max. operating speed 20 cpm (at rated load) Initial insulation resistance*
1
Min. 1,000 M(at 500 V DC)
Initial*2 breakdown voltage
Between open contacts
750 Vrms for 1 min.
Between contact and coil
4,000 Vrms for 1 min.
Initial surge voltage between contact and coil*
3
Min. 10,000 V
Operate time*4 (at nominal voltage) Max. 10ms (at 20°C 68°F) Release time (with diode)*4
(at nominal voltage)
Max. 10ms (at 20°C 68°F)
Temperature rise (at 70°C 158°F)
Max. 45°C with nominal coil
voltage and at 3 A contact
carrying current
(resistance method)
Shock resistance
Functional*5Min. 300 m/s2{approx. 30 G} Destructive*
6
Min. 1,000 m/s2{approx. 100 G}
Vibration resistance
Functional*
7
10 to 55Hz
at double amplitude of 1.5mm
Destructive
10 to 55Hz
at double amplitude of 1.5mm
Conditions for operation, transport and storage*
8
(Not freezing and condensing at low temperature)
Ambient temp.
–40°C to +70°C
–40°F to +158°F
Humidity 5 to 85% R.H.
Unit weight Approx. 4 g .14 oz
TYPICAL APPLICATIONS
• Air conditioner
• Refrigerator
• Hot water units
• Microwave ovens
• Fan heaters
ORDERING INFORMATION
Contact arrangement Coil voltage (V DC)
1: 1 Form A 4H: 4.5,
05: 5, 06: 6,
Packing style
Nil:
W:
Tube packing Carton packing
Product name
LD
UL/CSA, TÜV, VDE approved type is standard. Note: Tube packing: Tube: 50pcs, Case: 1,000pcs
Carton packing: Carton: 100pcs, Case: 500pcs
Ex. A LD 1 12 W
09: 9 ,
12: 12 18: 18
24: 24
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Page 2
LD (ALD)
TYPES AND COIL DATA (at 20°C 68°F)
DIMENSIONS
mm inch
REFERENCE DATA
Part No.
Nominal voltage,
V DC
Pick-up voltage,
V DC (max.)
(Initial)
Drop-out voltage,
V DC (min.)
(Initial)
Coil resistance,
(±10%)
Nominal
operating
current,
mA (±10%)
Nominal
operating power,
mW
Maximum
allowable voltage,
V DC
(at 20°C 68°F)
ALD14H 4.5 3.38 0.22 101 44.6 200 5.85
ALD105 5 3.75 0.25 125 40.0 200 6.5 ALD106 6 4.5 0.3 180 33.3 200 7.8 ALD109 9 6.75 0.45 405 22.2 200 11.7 ALD112 12 9 0.6 720 16.7 200 15.6 ALD118 18 13.5 0.9 1,620 11.1 200 23.4 ALD124 24 18 1.2 2,880 8.3 200 31.2
0.4 dia
016 dia
.016
.031
1.15
.045
.185
.008
.008
.134
Max. 20.5
.807
Max. 15.3
.602
Max. 7.2
.284
11.5
.453
1.05
.041
.276
Dimension: General tolerance Max. 1mm .039 inch: ±0.1 ±.004 1 to 3mm .039 to .118 inch: ±0.2 ±.008 Min. 3mm .118 inch: ±0.3 ±.012
PC board pattern (Bottom view)
Tolerance: ±0.1 ±.004
Schematic (Bottom view)
4-1.1 dia
4-.043 dia
(1.15)
(.045)
(1.05)
(.041)
11.5
.453
.185
.276
COIL
COM NO
1. Max. switching power 2. Life curve 3. Coil temperature rise
Sample: ALD112, 6 pcs. Point measured: inside the coil Contact current: 0 A, 3 A
20 30 50 100 200 3000
Contact voltage, V
Contact current, A
AC resistive load
DC resistive load
0
10
30
50
100
123
125V AC resistive load
Contact current, A
Life, ×10
4
Coil applied voltage, %V
Temperature rise, °C
70°C
1000 125 175150
70
60
50
40
30
20
10
0
3A
0A
20°C
4-(1). Operate time
Sample: ALD112, 6 pcs.
4-(2). Release time (without diode)
Sample: ALD112, 6 pcs.
4-(3). Release time (with diode)
Sample: ALD112, 6 pcs.
Coil applied voltage, %V
Operate time, ms
80 100 140120
10
8
6
4
2
0
Max.
Min.
Coil applied voltage, %V
Release time, ms
80 100 140120
10
8
6
4
2
0
Max.
Min.
Coil applied voltage, %V
Release time, ms
80 100 140120
10
8
6
4
2
0
Max.
Min.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Page 3
LD (ALD)
For Cautions for Use, see Relay Technical Information .
5-(1). Electrical life test (3 A 250 V AC, resistive load)
Sample: ALD112, 6 pcs. Operating speed: 20 cpm Ambient temperature: room temperature circuit:
Change of pick-up and drop-out voltage Change of contact resistance
250V AC
60Hz
G
12V DC
NO COM
0
20
10
40
60
80
30
50
70
90
100
0
Pick-up voltage
Drop-out voltage
Max.
Min.
Max. Min.
No. of operations, ×10
4
Ratio against the rated voltage, %V
10
0
10
20
30
40
50
60
70
80
90
100
0
Max. Min.
10
No. of operations, ×10
4
Contact resistance, m
5-(2). Electrical life test (3 A 30 V DC, resistive load)
Sample: ALD112, 6 pcs. Operating speed: 20 cpm Ambient temperature: room temperature circuit:
Change of pick-up and drop-out voltage Change of contact resistance
30V DC
G
12V DC
NO COM
0
20
10
40
60
80
30
50
70
90
100
020
Pick-up voltage
Drop-out voltage
Max. Min.
Max. Min.
10
No. of operations, ×10
4
Ratio against the rated voltage, %V
0
10
20
30
40
50
60
70
80
90
100
020
Max. Min.
No. of operations, ×10
4
Contact resistance, m
10
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.