Split System Submittal Data
System: 26PEK1U6 Indoor: S-26PK1U6 Outdoor: U-26PE1U6
Single Split System - Wall Mounted Heat Pumps
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
General Data
Power (V/P/Hz) 230/208/1/60
Circuit Ampacity (A) 15-30 Indoor-Outdoor
Fuse Size, Max.(A) 15-30 Indoor-Outdoor
Compressor DC Rotary Inverter
No. Used 1
R.L. Amps - L.R. (A) 12.9 - 17.5
Outdoor Unit
Fan type Propeller
Dia & Length (in.) - No. Speeds 18-7/64-1
Type Drive - No. Speeds DC Motor
No. Poles (RPM) 8 - 800
No. Motors (W) 1 - 90
CFM (High) 1765
F.L. Amps (A) 13.8
Coil Type Aluminum Fin & Copper Pipe
Fin Type - Pipe Type Slit Plate - Inner Rifled
Rows - F.P.I. 1 - 15.9
Face Area (sq.ft.) 7.26
Tube Size (in) 3/8"
Indoor Unit
Fan type Cross Flow
Dia & Length (in.) - No. Speeds 3-15/16 L33-15/64-1
No. Speeds 3 & Auto
No. Poles (RPM, High) 4 - 1224
No. Motors (W) 1 - 29
CFM (HI/Med/Lo) 559/475/390
Indoor Sound Rating (Hi) (dB-A) 48
F.L. Amps (A) 0.31
Coil Type
Fin Type - Pipe Type Slit Plate - Inner Rifled
Rows - F.P.I. 2 - 24.1
Face Area (sq.ft.) 2.57
Tube Size (in) 9/32"
Drain Connection Size (in.) 1-1/4"
Aluminum Plate Fin & Copper Tube
Approval:
Date:
Construction:
Unit#:
Drawing#:
Refrigerant R410A
Lbs. - R410a 4.19
Control Electric Expansion Valve
Connection Flare
Line Length, Max (ft.) 165
Line Difference, Max (ft.) 50 (outdoor lower),
100 (outdoor higher)
Line Size (in. O.D. Discharge) 3/8"
Line Size (in. O.D. Suction) 5/8"
Dimensions (HxWxD)
Indoor Unit (Crated) (in.) 15-11/32 x 47-27/32 x 11-17/32
Indoor Unit (Uncrated) (in.) 12-63/64 x 44-7/8 x 8-31/32
Outdoor Unit (Crated) (in.) 34-31/32 x 39-31/32 x 16-3/32
Outdoor Unit (Uncrated) (in.) 30-23/32 x 37 x 13 3/8
Weight (lbs.)
(Indoor) Net 40
(Indoor) Shipping 44
(Outdoor) Net 128
(Outdoor) Shipping 148
(Indoor) Shipping Volume (cu.ft.) 4.9
(Outdoor) Shipping Volume (cu.ft.) 13
Performance Data @ ARI Standard Conditions (230V)
Cooling
Total Capacity (BTU/H) 25,200 (9,500 - 25,200)
Sensible Capacity (BTU/H) 14,790
Latent Capacity (BTU/H) 10,410
SEER 14.9
Dehumidification (Pints/H) 8.1
Amps (A) 15.3/16.9
Power Inputs (W) 2,840/2,840
Outdoor Sound Rating (dB-A) 49
Heating
Total Capacity (BTU/H) 29,200 (8,000 - 29,200)
HSPF 10.2
Amps (A) 14/15.5
Max Amps (A) 14.8/16.4
Power Inputs (W) 2,620/2,620
Back-up Strip Heather (KW) 0.00/0.00
Outdoor Sound Rating (dB-A) High 49
Features
Controls Microprocessor
Remote Controller LCD Wired Type, Temp. Sensor
Temperature Control IC Thermostat
Timer 24 Hr. Program
Night Setback Built-In
Air Louver, Horizontal Manual
Air Louver, Vertical Automatic
Power Failure Automatic
Changeover
Heating/Cooling Automatic
Changeover
Self-Diagnosis Built-In
Air Filter Washable, Anti-Mold
Built in
Built-In
Built-In
Option
Refrigerant Line Set Available
Fresh Air Intake N/A
Airduct Extension N/A
Indoor Frame Extension N/A
Condensate Drain Pump Available
Non-Removeable Remo-con
Bracket
Operating Range
Cooling (Max) 95F DB/71F WB 115F DB
Cooling (Min) 67 DB/57F WB 0F DB
Heating (Max) 80F DB/67F WB 75F DB/65F WB
Heating (Min) -DB/-WB 5F DB
Indoor Air Intake Temp
Available
Outdoor Air Intake Temp
Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144
us.panasonic.com/aircon