General Data
Power (V/P/Hz) 230/208/1/60
Circuit Ampacity (A) 15-30 Indoor-Outdoor Fuse Size, Max.(A) 15-30 Indoor-Outdoor
Compressor DC Rotary Inverter
No. Used 1 R.L. Amps - L.R. (A) 12.9 - 17.5
Outdoor Unit
Fan type Propeller Dia & Length (in.) - No. Speeds 18-7/64-1 Type Drive - No. Speeds DC Motor No. Poles (RPM) 8 - 800 No. Motors (W) 1 - 90 CFM (High) 1765 F.L. Amps (A) 13.8
Coil Type Aluminum Fin & Copper Pipe
Fin Type - Pipe Type Slit Plate - Inner Rifled Rows - F.P.I. 1 - 15.9 Face Area (sq.ft.) 7.26 Tube Size (in) 3/8"
Indoor Unit
Fan type Cross Flow Dia & Length (in.) - No. Speeds 3-15/16 L33-15/64-1 No. Speeds 3 & Auto No. Poles (RPM, High) 4 - 1224 No. Motors (W) 1 - 29 CFM (HI/Med/Lo) 559/475/390 Indoor Sound Rating (Hi) (dB-A) 48 F.L. Amps (A) 0.31
Coil Type
Fin Type - Pipe Type Slit Plate - Inner Rifled Rows - F.P.I. 2 - 24.1 Face Area (sq.ft.) 2.57 Tube Size (in) 9/32" Drain Connection Size (in.) 1-1/4"
Aluminum Plate Fin & Copper Tube
Approval: Date: Construction: Unit#: Drawing#:
Refrigerant R410A
Lbs. - R410a 4.19 Control Electric Expansion Valve Connection Flare Line Length, Max (ft.) 165 Line Difference, Max (ft.) 50 (outdoor lower),
100 (outdoor higher) Line Size (in. O.D. Discharge) 3/8" Line Size (in. O.D. Suction) 5/8"
Dimensions (HxWxD)
Indoor Unit (Crated) (in.) 15-11/32 x 47-27/32 x 11-17/32 Indoor Unit (Uncrated) (in.) 12-63/64 x 44-7/8 x 8-31/32 Outdoor Unit (Crated) (in.) 34-31/32 x 39-31/32 x 16-3/32 Outdoor Unit (Uncrated) (in.) 30-23/32 x 37 x 13 3/8
Weight (lbs.)
(Indoor) Net 40 (Indoor) Shipping 44 (Outdoor) Net 128 (Outdoor) Shipping 148
(Indoor) Shipping Volume (cu.ft.) 4.9 (Outdoor) Shipping Volume (cu.ft.) 13
Performance Data @ ARI Standard Conditions (230V)
Cooling
Total Capacity (BTU/H) 25,200 (9,500 - 25,200) Sensible Capacity (BTU/H) 14,790 Latent Capacity (BTU/H) 10,410 SEER 14.9 Dehumidification (Pints/H) 8.1 Amps (A) 15.3/16.9 Power Inputs (W) 2,840/2,840 Outdoor Sound Rating (dB-A) 49
Heating
Total Capacity (BTU/H) 29,200 (8,000 - 29,200) HSPF 10.2 Amps (A) 14/15.5 Max Amps (A) 14.8/16.4 Power Inputs (W) 2,620/2,620 Back-up Strip Heather (KW) 0.00/0.00 Outdoor Sound Rating (dB-A) High 49
Features
Controls Microprocessor Remote Controller LCD Wired Type, Temp. Sensor
Temperature Control IC Thermostat Timer 24 Hr. Program Night Setback Built-In Air Louver, Horizontal Manual Air Louver, Vertical Automatic Power Failure Automatic
Changeover Heating/Cooling Automatic
Changeover Self-Diagnosis Built-In Air Filter Washable, Anti-Mold
Built in
Built-In
Built-In
Option
Refrigerant Line Set Available Fresh Air Intake N/A Airduct Extension N/A Indoor Frame Extension N/A Condensate Drain Pump Available Non-Removeable Remo-con
Bracket
Operating Range
Cooling (Max) 95F DB/71F WB 115F DB Cooling (Min) 67 DB/57F WB 0F DB Heating (Max) 80F DB/67F WB 75F DB/65F WB Heating (Min) -DB/-WB 5F DB
Indoor Air Intake Temp
Available
Outdoor Air Intake Temp
Panasonic North America Air Conditioning Division