paasche DC850R Pro Instruction Manual

Page 1
INSTRUCTION Manual DC850R - 3/6/2018
PAASCHE
DC850R Pro Series
Air Compressor
3/4 HP, 120 Volts, 60 Hz,
Max Operating Pressure 100 PSI.
Weight: 36.3 lbs (16.5 kg)
Features:
Portable & Lightweight
Ultra Quiet 58 Decibels
Thermally Protected
Steady Air Flow
Regulator
Auto Stop and Start
1/4” NPT Fittings
Dual Quick Connects
WARNING: When a flammable liquid is sprayed, there may be danger of fire or explosion especially in a closed room. Keep compressor at least 20 feet away from areas where hazardous concentrations of flammable vapors are likely to occur. Disconnect power before servicing. ATTENTION: Lorsqu'un liquide inflammable est pulverise, il peut y avoir danger d'incendie ou d'explosion, specialement dans une piece fermee; garder le compresseur a au moins 20 pieds des endroits ou des concentrations dangereuses de vapeurs inflammables sont susceptibles de se produire. Debrancher avant toute maintenance.
Compressor Specs:
• Dual Piston / Oil Free
• 3/4 HP
• 110-120 Volt /60HZ 5.5 Amps
• 100 Max Pressure
• 2.40 CFM @ 40psi
1.50 CFM @ 90 psi
Tank Size: 6L =1.585 Gallons
• 36 lbs (16.3kg)
Carrying Handle
1)
Before operating Compressor, Install Muffler on compressor head "Hand tight" with drain hose facing down.
Apply PTFE pipe tape (Included) to male thread of Quick connect
2)
(Included). Thread onto 1/4"Airbrush hose end. Attach airbrush to 1/8" hose end.
Plug compressor into grounded outlet, pull up on red button on black box.
3)
When compressor stops, press trigger on airbrush and hold down while
4)
turning large red air regulator clockwise to increase air, or counterclockwise to decrease air. When gauge reaches desired pressure release trigger.
• Dim: 17”L x 14”W x 13”H
• 5 Foot Electric Cord
Operation Instructions:
5)
Turn off compressor after use and loosen drain valve at bottom of compressor to empty out any standing water in tank .
Page 2
GENERAL & SAFETY INFORMATION
GENERAL INFORMATION
The maximum pressure of the compressor is 0-100 PSI . The maximum operating pressure while spraying will vary depending on size of fluid tip, needle and aircap.
THERMAL PROTECTOR
The motor of this compressor has a thermal overload protector. If the motor should overheat, the overload protector will shut off the motor. If this should occur, unplug the compressor and allow the motor to cool (approx. 5 minutes) and restart compressor.
SEALING OF AIR HOSE
When attaching the female pipe thread fitting from your air hose to the compressor use PTFE pipe thread tape (Included) on the Male quick connect. Failure to do so may cause an air leak and your compressor will not shut off as it should. NOTE: This unit does not require any lubricants or oil. Applying oil to any part could result in damage to the compressor. All bearings, including those in the motor, are grease packed.
Included male quick connects
Pull-ON.....Push-OFF
Air outlet gauge
Muffler
Air Regulator
Tank pressure gauge
AUTOMATIC SHUT-OFF FEATURE
This compressor has a built-in pressure switch that automatically shuts-off the compressor when the tank is full. It will immediately start again as soon as the tank reaches the pre-set psi.
WARNINGS
• Only use 110-120 volt, 60 cycle power supply for this compressor.
• Before plugging in check to make sure compressor is in good condition.
• Only operate compressor in accordance with current safety regulations.
• Keep working area clean and uncluttered and make sure area is well ventilated. Never operate the compressor in the presence of flammable liquids or gases.
• Compressor air can produce dust, dirt and loose particles it comes in contact with. To prevent possible injury always wear safety goggles or glasses. Never point any nozzle or spray toward a person.
The air compressor is powered by electricity. Like any electric device, if not used properly it can cause electric shock.
• Keep out of reach of children.
QM-2/QM-4 manifolds. For
1)
Suggested Accessories:
Tank Moisture drain valve
multiple hose hook ups.
2)
Hose adapter. If your hose has a 1/8” NPT fitting get the HF-592. For the opposite get HF-116.
A-194 Airbrush Holder
3)
AC-7 Airbrush Cleaning Brushes
4)
Paasche Airbrush Company
4311 North Normandy Avenue Chicago, IL 60634-1395 Phone: 773-867-9191 • Fax: 773-867-9198 Website:
paascheairbrush.com E-Mail: info@paascheairbrush.com
This compressor is
Manufactured in China for Paasche
CE Listed