Ozito PPW-801 Instruction Manual

0
1
2
3
4
5
6
Bar
POTABLE PRESSURE PUMP
800W
INSTRUCTION MANUAL SPECIFICATIONS
Motor: 800W Max. Flow Rate: 3,200 l/h Max. Lift: 8m Max. Head: 38m Inlet & Outlet: 25.4mm (1”BSP) Female Max. Delivery Pressure: 3.8 bar Water Temp.: 1C to 35ºC IP Rating: IPX4 Weight: 8.4kg
PPW-801
WHAT’S IN THE BOX
IN ORDER TO MAKE A CLAIM UNDER THIS WARRANTY YOU MUST RETURN THE PRODUCT TO YOUR NEAREST BUNNINGS WAREHOUSE WITH YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO RETURNING YOUR PRODUCT FOR WARRANTY PLEASE TELEPHONE OUR CUSTOMER SERVICE HELPLINE:
Australia 1800 069 486 New Zealand 0508 069 486
3 YEAR REPLACEMENT WARRANTY
Your product is guaranteed for a period of 36 months from the original date of purchase. If a product is defective it will
be replaced in accordance with the terms of this warranty. Warranty excludes consumable parts, for example: O-rings, bearing, seals gaskets.
WARNING
The following actions will result in the warranty being void.
• If the tool has been operated on a supply voltage other thanthatspeciedonthetool.
• If the tool shows signs of damage or defects caused
by or resulting from abuse, accidents or alterations.
• Failure to perform maintenance as set out within the instruction manual.
• If the tool is disassembled or tampered with in any way.
• Professional, industrial or high frequency use.
WARRANTY
TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE. A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE WARRANTY POLICY OR PROCEDURE.
OZITO Australia/NewZealand(HeadOfce) 1-23 Letcon Drive, Bangholme, Victoria, Australia 3175.
Thebenetsprovidedunderthiswarrantyareinaddition to other rights and remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded at law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Generally you will be responsible for all costs associated with a claim under this warranty, however, where you have suffered any additional direct loss as a result of a defective product you may be able to claim such expenses by contacting our customer service helpline above.
ozito.com.au
0716
0
1
2
3
4
5
6
Bar
Potable Pressure Pump
ONLINE MANUAL
Scan this QR Code with your mobile device to take you to the online manual.
0
1
2
3
4
5
6
Bar
This constant pressure pump is designed for pumping clean water in the house and garden. It is ideal for providing domestic water supply to laundries, toilets and outdoor taps, combined with a trigger nozzle and hose for garden watering and washing cars. Tested to AS/NZS 4020 as suitable for use in contact with drinking water.
Your pump requires no assembly before use other than the connection of suitable inlet/outlet hose or pipe adaptors (not included).
Positioning the pump
The device must be placed on a horizontal, level surface that is
sufciently capable of supporting
the total weight of the device
when lled with water.
Four mounting recesses
allow for xing the base to the
mounting surface (bolts not supplied).
Note: The installation site must be well ventilated and protected from
the effects of weather.
Note: When operating indoors you must ensure that there is a drain in
the oor or a mechanism to prevent leakage.
1. Suction inlet
2. Pressure gauge
3. Priming plug
4. Discharge outlet
5. Carry handle
6. On button
7. Indicator lights
8. Water drain plug
9. Mounting recesses
10. Base
POTABLE PRESSURE PUMP
KNOW YOUR PRODUCT
1. SETTING UP
SETUP & PREPARATION
WARNING!: ENSURE THE PUMP IS DISCONNECTED
FROM THE POWER SUPPLY BEFORE PERFORMING
ANY OF THE FOLLOWING OPERATIONS.
1
8 9 10
4 5 6 732
Connecting to the discharge outlet
1. Teon tape (not included) is required on
threads to ensure a water tight seal and
prevent any leakage. Wind Teon clockwise on ttings
2. Remove the plastic protection cover from the discharge outlet.
3. Insert a 1” male threaded hose adaptor (not included).
4. Securely attach the output hose or pipe (not included) to the other end of the adaptor. Ensure you have the correct diameter hose or pipe that is compatible with your water discharge application.
Note: The discharge hose or pipe you are using must have a minimum
diameter of 19mm (3/4’’).
Note: Ensure the discharge hose or pipe is not restricted in any
way and nothing is obstructing the hose or pipe when the pump is in operation.
Connecting to the suction inlet
1. Teon tape (not included) is required
on threads to ensure a water tight seal
and prevent any leakage. Wind Teon clockwise on ttings.
2. Remove the plastic protection cover from the suction inlet.
3. Insert a 1”
male threaded hose adaptor (not included).
Tighten rmly
with a spanner (not included).
4. Securely attach the input hose (not included) or pipe to the other end of the adaptor. Ensure you have the correct diameter hose or pipe that is compatible with your water drawing source.
Note: The suction pipe should have an internal diameter of at least
25.4mm (1”); it must be kink resistant and suitable for pump use.
Ensure the input hose or pipe is not restricted in any way.
2. SUCTION INLET 3. DISCHARGE OUTLET
0
1
2
3
4
5
6
Bar
0
1
2
3
4
5
6
Bar
0
1
2
3
4
5
6
Bar
0
1
2
3
4
5
6
Bar
WARNING!: RISK OF INJURY! IF THE COMPONENTS
ARE NOT COMPRESSION-PROOF OR IF THEY ARE IMPROPERLY INSTALLED, THE PRESSURE LINE COULD BURST DURING OPERATION.
Loading...
+ 5 hidden pages