Outdoor Great Room Gallery Wall-Mounted Fireplaces User Manual

Tools Required-
Philips Screwdriver or
power drill with Philips tip (preferred)
Leveling device
NOTE: Heater unit may be removed or left attached to the fire box for this installation. Use the provided
diagrams for clearances for each configuration.
Removing the heater unit (optional)
Remove 4 screws from underside of heater unit Unplug the heater from the fire box by
squeezing the tabs on the white quick connector plug and pulling downward. Set heater assembly aside or dispose of appropriately.
Remove
Relocate Heat and lighting controls
Remove the screws holding the access panel on
the underside of the fire box on.
There is a small quick connect plug inside this
access panel. Plug the control module (included with this kit) into the quick connect plug and screw access panel back into place, threading wire through hole in access panel door.
Once fireplace is installed into a wall, the
control button module can be mounted to the
wall surface below it using a screw or a double-sided adhesive strip.
Connect control button module to
fire box
Remove screws
Gallery Wall-Mounted Fireplaces
Installing the fireplace into a wall as a built-in unit
Included in this kit-
Wall Mounting Brackets (2) M5x10 Screws (4) Control button relocation module (1)
90238 Rev B 11/8/12
Prepare Your Wall for Installation
DO NOT CUT INTO ANY WALL WITHOUT FIRST ENSURING THAT THE AREA IS FREE OF HIDDEN
ELECTRICAL, GAS, OR PLUMBING LINES. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR DEATH
With front glass removed, measure your fireplace. You can then use these measurements to select an
appropriate spot on a wall for inserting your fireplace.
Use framing clearance diagrams shown on the next page for appropriate cutout sizing. IF STUDS ARE NOT PRESENT ON LEFT AND RIGHT SIDES OF CUTOUT, STUDS OR OTHER INTERIOR SUPPORT
SHOULD BE FABRICATED TO SUPPORT THE WEIGHT OF FIREPLACE. SEE DIAGRAM ON NEXT PAGE.
7/8
13/16”
1/2
1/2
1/2
1/2
5/8
5/8
1 1/8
1 1/8
2 1/2
2 1/2
5 5/8”
DIMENSIONS SHOWN ARE MINIMUM
CLEARANCES TO FRAMING
FOR FIREPLACES WITH HEATER ATTACHED
DIMENSIONS SHOWN ARE MINIMUM
CLEARANCES TO FRAMING
FOR FIREPLACES WITH HEATER REMOVED
Distance from back of fireplace to a
surface should be 7/8 or greater.
Once installed, the fireplace (including glass front) will protrude 2 5/8 from the wall surface.
90238 Rev B 11/8/12