Outdoor Great Room Crystal Fire User Manual

Crystal Fire
User Manual for: CF-20-LP (NG) , CF-1224-LP (NG), CF-2424-LP(NG), CF-1242-LP(NG)
CAUTION
DO NOT DISCARD THIS MANUAL
operation.
WARNING
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may result causing property
damage, personal injury, or loss of life.
Do not store gasoline or other flammable vapors or
If you cannot reach your gas supplier, call the
HOT! DO NOT TOUCH. SEVERE BURNS MAY RESULT. CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot during operation and cool-down.
Keep children away.
WARNING For outdoor use only
WARNING It is imperative the burner be kept clean
WARNING
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Read the installation and maintenance instructions thoroughly before installing or servicing this equipment.
Installation and service of this appliance
by an NFI certified professional.
Important operating and
maintenance instructions included.
Read, understand, and
follow these instructions for safe installation and
What to do if you smell gas:
Installation and service must be performed by a
liquids in the vicinity of this or any other appliance.
Do not try to light any appliance Do not touch any electrical switch. Do not
Immediately call your gas supplier from a
qualified installer, service agency, or the gas supplier.
use any phone in your building.
neighbor’s phone. Follow the gas supplier’s
Instructions.
fire department.
CAREFULLY SUPERVISE children near this
appliance.
Alert children and adults to hazards of high
temperatures.
Keep clothing, furniture, draperies, and
other combustibles away.
Page | 1 www.outdoorrooms.com Crystal Fire 42435 REV J 5.24.12
should be performed by qualified personnel. The Outdoor GreatRoom Company suggests NFI certified, factory­professionals, or technicians supervised
Read this manual before installing or operating this appliance.
Please retain this owner’s manual for future reference.
Congratulations on selecting an Outdoor GreatRoom Company decorative gas appliance. The Crystal Fire you have selected is designed to provide the utmost in safety, reliability, and efficiency.
As the owner of a Crystal Fire, you’ll want to read and carefully follow all of the instructions contained in this owner’s manual. Pay special attention to all cautions and warnings.
This owner’s manual should be retained for future reference. We suggest you keep it with other important
documents and product manuals.
This information contained in this owner’s manual, unless noted otherwise, applies to all models and gas
control systems.
Your new Crystal Fire will give you years of durable use and trouble-free enjoyment.
Homeowner Reference Information
Model name:______________________________ Date of purchase/installation_________
Serial Number:___________________________ Location on appliance:_________________
Dealer purchased from:____________________ Dealer Phone:________________________
Notes:______________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________
We recommend that you record the following
pertinent information about your appliance
Listing Label Information/Location
The model information regarding your specific appliance can be found on the rating plate attached to your burner via a metal chain. See the sample rating plate below for locations of specifications.
Model
Fuel Type
Orifice Size
Serial no.
Congratulations
Page | 2 www.outdoorrooms.com Crystal Fire 42435 REV J 5.24.12
Table of Contents
1. Listing and Code Approvals
2. Getting Started
3. Framing Clearances
c. Framing an enclosure for LP supply system
4. Fuel Information
d. LP Gas supply
5. Appliance Setup
6. Operating Instructions
7. Finishing
8. Converting to Natural Gas
9. Troubleshooting
10.Maintaining and servicing the appliance
11.Reference Materials
CF20
Flexible metal gas line
CF-1224
CF-2424 , CF1242
(*Included with remote-operated unit only)
What’s included…
a. Appliance certification b. BTU specifications
a. Design and installation considerations b. Tools and supplies required c. Inspection of appliance and components
d. Step-by-step lighting instructions
a. Selecting a location b. Required clearance to combustibles
a. Fuel b. Gas pressure
c. Gas connection
a. Burner assembly b. Glass installation
a. Before lighting b. Lighting the fire c. After the fire is lit
a. Service parts list b. Limited one-year warranty c. Contact information
20” Round burner
Black propane hose
with regulator
Ball valve
Piezoelectric igniter #43 Orifice (LP)
#31 Orifice (NG)
2 bags of decorative
glass
12”x24” burner
Black propane hose with
regulator
Flexible metal gas line
Ball valve
Piezoelectric igniter
#43 Orifice (LP)
#31 Orifice (NG)
2 bags of decorative glass
Page | 3 www.outdoorrooms.com Crystal Fire 42435 REV J 5.24.12
24”x24” OR 12”x42” burner
Black propane hose with regulator
Flexible metal gas line
Ball valve
Piezoelectric igniter
#36 Orifice (CF2424 only- home LP)
#31 Orifice( CF1242 only- Home LP)
#43 Orifice (20lb LP)
#17 Orifice (CF2424 only- NG)
#21 Orifice (CF1242 only -NG)
4 bags of decorative fire glass
Remote *
U-shaped heat shield bracket (used for
remote operation installs only)
1 Listing and Code Approvals
A. Appliance Certification B. BTU Specifications
MODEL:
Outdoor Gas Fireplaces, CR-97-003
B149.2, Propane Installation Code.
Model
Orifice Size LP NG
CF-20
CF-1224
CF-2424
Whole-house
20lb tank
#43
#43
#36
#43
#31
#31 #17
CF-1242
#31
#21
Max input
BTU
Max input
BTU
Max input
BTU
Max input
BTU
60,000 60,000
55,000 51,000
79,000
61,000
107,000
100,000
90,000
20lb tank
#43
Whole-house
60,000
CRYSTAL FIRE CF-20-LP, CF-1224, CF-2424,
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Decorative Gas-Fired Outdoor Fireplace
STANDARD: IAS US requirements for Outdoor gas
fireplaces, Draft 4-96 and CSA requirement for
The Crystal Fire has been tested in accordance with IAS US requirements for Outdoor Gas Fireplaces, Draft 4-96 and CSA requirement for Outdoor Gas Fireplaces, CR-97- 003 for Canada and has been listed by Underwriters Laboratory (UL) for installation and operation as described in these installation and operating instructions.
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1 or CAN/CGA-B149.1, National Gas Installation Code or CAN/CGA-
Page | 4 www.outdoorrooms.com Crystal Fire 42435 REV J 5.24.12
2 Getting Started
This appliance is a Decorative Gas Appliance for
be used
for cooking.
Place the Crystal Fire on a flat and stable surface in an outdoor location such as a patio or deck. This location must be adjacent to the gas supply line or LP gas supply cylinder. locate the appliance where it will get excessively wet or submerged in water.
A. Design and Installation Considerations
When planning an appliance installation, it’s necessary to
Framing and finishing details. See sections 3,7
B. Tools and Supplies Required
Before beginning the installation, be sure that the
WARNING
The Outdoor GreatRoom Company
Installation and use of any damaged
Modification of the burner assembly
WARNING
control which has been underwater.
CAUTION
Sharp Edges
during installation.
WARNING
Do not burn solid fuels in this gas appliance
C. Inspect the Appliance and Components
WARNING
Inspect appliance and components for damage. Damaged parts may impair safe operation.
Report damaged parts to your dealer.
WARNING
Asphyxiation Risk
enclosed structure or unvented appliance
Carefully remove all burner
maximum safety and benefit.
This gas appliance is for outdoor use in a
well-ventilated space.
This unit must not be installed inside an
determine the following information before installing:
Where will the appliance be installed? See section 3
Gas supply piping. See section 4
following tools and supplies are at hand.
Gloves
Safety Glasses
Phillips screwdriver
Non-corrosive leak-check solution
Wrenches
1 AAA battery
disclaims any responsibility for, and
the warranty will be voided by, the
following actions:
Do NOT use this appliance if any part of it has
been underwater. Have a qualified service
technician inspect the appliance and replace any part of the control system and any gas
Wear protective gloves and safety glasses
Do NOT install damaged, incomplete,
or substitute components
components.
Installation other than as instructed
by the Outdoor GreatRoom
Any such action may cause a fire hazard
Company.
Page | 5 www.outdoorrooms.com Crystal Fire 42435 REV J 5.24.12
components from packaging.
Read all instructions before beginning
installation. Follow these instructions carefully during installation to ensure
Clearances to Combustibles
SIDE WALL
3 Framing and Clearances
Note:
individual design preference.
Fire Risk
Locate appliance away from traffic areas
WARNING
72 inches to overhang from
of metal bowl.
METAL
BOWL
If you are not using an
8”
8”
8”
8”
8”
Illustrations reflect typical installations
and are FOR DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to
scale.
Actual installation may vary due to
Provide adequate clearance:
Around air openings
For service access.
top
Outdoor GreatRoom Company table with this burner, be sure to mount to a non­combustible surface
maintaining at least 8”
to combustible surfaces and framing below the surface of burner.
Page | 6 www.outdoorrooms.com Crystal Fire 42435 REV J 5.24.12