Ouellet OVE User Manual

rd
180, 3
Avenue, L’Islet, Quebec, G0R 2C0 CANADA
Tel.: (418) 247-3947, 1 800-463-7043
Fax: (418) 247-7801, 1 800-662-7801
www.ouellet.com
INSTALLATION INSTRUCTIONS
“OVE Series”
1. Use the template provided with the heater. Make a minimum opening of 2 in. (51 mm) deep. Recom­ mended distance from heater to fl oor is 12 in. (305 mm).
2. Remove the heater front panel.
3. Remove the connection box cover.
4. Remove the appropriate knock-out from the box for the electrical supply.
5. Secure the heater by using the provided screws. Remove 3/16 in. (4.8 mm) side knock-outs or use the holes at the back of the heater.
6. Make connections according to local and national codes.
7. Put all covers back on the heater and test. a) Adjust heater thermostat at maximum setting (1500W). b) Slowly turn down thermostat setting for 750W output. (Model T and TM). c) Adjust thermostat at minimum setting and set the timer (1500W) (Model TM).
SURFACE WALL MOUNTING
1. Locate the power supply leads behind the planned location of the heater. Recommended height from heater base to fl oor is 12 in. (305 mm).
2. Follow steps 2 to 7 of the RECESS WALL MOUNTING. CONTROL
Without control: Maintains room temperature by a line-voltage wall thermostat approved for inductive loads (not supplied). A pulsating elec­tronic thermostat must not be used with this model. (1500W) With thermostat: Maintains room temperature 750W (low-speed). Thermostat automatically changes heater from 750W (low-speed) to 1500W (high-speed) when necessary. With thermostat and timer combination: Maintains room temperature 750W (low-speed). The unit automatically changes to 1500W (high-speed) when neces­sary. The 0-60 minute timer allows for quick heat-up to 1500W (high-speed) before a bath or shower. The heater returns to the thermostat mode automatically or manually.
KEEP THIS INSTRUCTION PAMPHLET
FOR THE USER INS22-200306-05
ATTENTION
Basic precautions should always be taken to reduce the risk of fi re, electric shock, and injury:
- Read all instructions before using this heater.
- This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, like furniture, pillows, bedding, papers, clothes, and curtains at least 48 in. (1220 mm) from the front of the heater.
- We recommend to keep a distance of 39 1/2 in. (1004 mm) minimum from a bathtub according to local and national codes.
- Do not use outdoors.
- Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fi re, or damage the heater.
- Do not block air intakes or exhaust in any way whatsoever.
- A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or fl ammable liquids are used or stored.
- Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fi re, electric
shock, or injury.
ATTENTION (CONTINUED)
AMERICAN VERSION ONLY: This heater includes a visual alarm to warn that parts of the heater are getting excessively hot. If the light turns on, immediately turn the heater off and inspect for any objects on or adjacent to the heater that may cause high temperatures. DO NOT OPERATE THE HEATER WITH THE ALARM LIGHT IS ON.
MAINTENANCE
- Once every quarter, remove the front panel and use a vacuum cleaner to remove the dust accumulation inside the heater.
- Cleaning should be done while the heater is disconnected from the main service panel.
- A qualifi ed technician should perform any other servicing.
NOTICE Heater will produce a light smoke when it is new and energized for the fi rst time. It is normal, and will end a couple of minutes later. When the heater is used in a dusty or smoky environment, the air exit grill may turn yellow. To alleviate the problem, we sug­gest that you clean the heater hot air exit more often especially when dust and smoke cannot be avoided. Never let the heater function in a very dusty environment.
RECESS WALL MOUNTING
Wall opening 11 11/16’’ X 15 1/16’’ X 2’’
(296 mm X 383 mm X 51 mm)
Connection box cover
Ground screw
Holes for recess mounting
Front panel
SURFACE WALL MOUNTING
This drawing indicates screw positions
and wall area cover by the heater.
1/2’’
(12 mm)
2’’ (51 mm)
8 7/16’’ (214 mm)
Surface
of the heater
9 1/2’’
X 14 13/16’’
241 mm X 376 mm
2 3/8’’ (60 mm)
1/2’’
(12 mm)
Screw
positions
KOE Ø3/16’’
KOE Ø4.8 mm
10 1/2’’ (266 mm)
Wire cable
outlet
KOE Ø7/8’’
KOE Ø22 mm
1 3/4’’ (45 mm)
WARRANTY OUELLET CANADA INC. warrants the electric heating element of the OVE series for fi ve (5) year period; and its component parts against defects in material and workmanship for a two (2) year period following the date of purchase, under normal use and service, when proof of purchase of such is provided to the manufacturer. The obligation of Ouellet Canada inc., under the terms of this war­ranty, will be to supply a new unit and this releases the manufacturer from paying the installation costs or other secondary charges linked to replacing the unit or the component part(s).
INS22-200306-05