Ouellet OCH-WB User Manual

180, 3e Avenue, L’Islet, Québec, G0R 2C0, CANADA
Tel.: (418) 247-3947, 1-800-463-7043, Fax: (418) 247-7801
www.ouellet.com
INSTRUCTIONS
“OCH and OCH-WB” Series
WARNING
When using electrical appliances, basic precautions should always be taken to reduce the risk of fi re, electrical shock and injury, including the following.
CAUTION
NON-RESIDENTIAL USE IN THE UNITED STATES
Read carefully these instructions before installation, operation
of the heater. Failure to adhere to the instructions could result in re, electric shock, serious personal injury, and death or property damage. Review frequently for continuing safe operation and instruction of future users, if necessary.
IMPORTANT INSTRUCTIONS
- Read all instructions before using this heater.
- This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Use the handle when moving this heater. Keep combustible materials, like furniture, pillows, bedding, papers, clothes, and curtains at least 3 ft. (0.9 m) from the front of the heater and keep them away from the sides and rear.
- Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
- Do not use outdoors.
- Always unplug heater when not in use.
- This heater is not intended for use in bathrooms, laundry areas and similar indoor locations. Never locate heater where it may fall into a bathtub or other water container.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffi c area and where it will not be tripped over.
- Connect to properly grounded outlets only.
- Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electrical shock or fi re, or damage the heater.
- To prevent a possible fi re, do not block air intakes or exhaust in any way whatsoever. Do not use on soft surfaces, like a bed, where openings may become blocked.
- This heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint or fl ammable liquids are used or stored.
- Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fi re, electrical shock, or injury to persons.
- This heater is not approved for use in corrosive atmospheres, wet or very humid locations such as marine, green house or chemical storage areas.
- To disconnect heater, rotate thermostat knob full counter­ clockwise, then remove plug from outlet.
- Do not operate any heater with a damaged cord or plug or after the heater malfunctions, has been dropped or damaged in any manner. Discard heater, or return to authorized service facility for examination and/or repair.
- Avoid the use of extension cord because the extension cord may overheat and cause a risk of fi re. However, if you have to use an extension cord, the cord shall be No. 8 AWG minimum size and rated for not less than 30 amps.
KEEP THESE INSTRUCTIONS.
USER INSTRUCTIONS
CAUTION
- To prevent possible overheating keep at least 5 ft. (1.53 m) clearance in front of heater.
- Respect minimum clearance installation as specifi ed in these instructions.
- This heater is for use on 240 volts. The cord has a plug as shown in Figure 1.
- No adapter is available for this blade confi guration, and none should be used. The type of outlet is a 240 volt grounding outlet. When properly installed, it provides a ground connection through the cord to the heater to protect the operator from electrical shock.
Figure 1
Plug:
6 - 20 P
4 kW
IMPORTANT
This heater has an Automatic reset thermal high-limit that will deenergize the heating elements if the interior temperature of the heater exceeds its setting. The fan will continue to run until the residual heat is removed from the heater. The limit will automatically reset when the heater interior temperatures fall below its setting.
6 - 30 P
4.8 kW
Floor mounting:
Place heater on fl oor, plug into proper wall outlet and adjust heater to direct airfl ow.
Wall or ceiling mounting
- Install heater not less than 3 1/2 in. (90 mm) from the wall and 6 in. (150 mm) from ceiling.
- Heater may be mounted for horizontal air discharge only.
- Maximum mounting height: 8 ft. (2.44 m).
- The wall or the ceiling must be able to support the combined weight of the heater and the mounting bracket 11 lbs (5 kg).
- Fix the bracket to the wall or the ceiling structural members with the supply screws.
- Plug into proper wall outlet. To turn on heater:
- Plug in heater.
- Rotate thermostat knob full clockwise. The fan will start and the element will heat.
- When the desired temperature is reached, turn the thermostat counter-clockwise slowly till the fan stop. To set the room temperature, turn slowly the thermostat clockwise or counter-clockwise.
To turn off heater:
- Rotate thermostat knob full counter-clockwise and then remove plug from outlet.
(Model OCH-WB only):
MAINTENANCE INSTRUCTIONS
- The heater motor is permanently lubricated.
- Occasional cleaning of the inlet grille will prevent clogging. Use a vacuum with a brush attachment.
- Any other servicing should be performed by an authorized service representative.
- Disconnect heater prior to cleaning or servicing.
Electrical Diagram
OUELLET CANADA INC. warrants the component parts of its products against defects in material and workmanship for a one (1) year period following the date of purchase, under normal use and service, when proof of purchase of such is provided to the manufacturer. The obligation of Ouellet Canada Inc., under the terms of this warranty, will be to supply a new unit and this omits the manufacturer to bear the installation costs or other secondary charges linked to replacing the unit or the component part(s).
L1 L2
GND
Thermostat
High-limit
WARRANTY
INS176-200806-06