Orion WB-71 Installation And User Manual

W
W
Installation and User’s Guide
BIG SCREEN FLAT LCD DISPLAY MOUNT MODEL
B-71
ALL MOUNT BRACKET
Installation and User’s Guide
http://www.orionimages.com
All contents of this document may change without prior notice, and actual product appearance may differ from that depicted herein
http://www.orionimages.com
Installation and User’s Guide
TABLE OF CONTENTS
Warning Statements Parts List Installation Tools Mounting Bracket Installation
WB-71 Installation Installing the Flat Panel Display (WB-71) Technical Specifications Warranty Contact
.............................................................................................................................
................................................................................................................................
................................................................................................................................
............................................................................................................
..................................................................................................................
...............................................................................................
................................................................................................................
......................................................................................................
..............................................................................
4 5 5
9 12 14 17
18 18
2
7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310
pg2
http://www.orionimages.com
WARNING
WARNING
WARNING
THE WALL STRUCTURE MUST BE CAPABLE OF SUPPORTING AT LEAST A MAXIMUM WEIGHT OF 50 LBS. IF NOT, THE WALL MUST BE REINFORCED. PROPER INSTALLATION PROCEDURE BYAQUALIFIED SERVICE TECHNICIAN, AS OUTLINED IN THE INSTALLATION INSTRUCTIONS, MUST BE ADHERED TO. FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURY, OR EVEN DEATH.
SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE INSTALLATION OF THIS PRODUCT. USE PROPER SAFETY GEAR AND TOOLS FOR THE INSTALLATION PROCEDURE TO PREVENT PERSONAL INJURY.
PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS SHOULD BE READ AND COMPLETELY UNDERSTOOD. THE INSTALLATION INSTRUCTIONS MUST BE READ TO PREVENT PERSONAL INJURY AND PROPERTY DAMAGE. KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE.
Indicates that the power plug is to be disconnected from the power outlet.
Safety precautions must be taken at all times.
Warning and Caution statements.
A secure structure must support the weight, or load, of the display. When mounting to a wall that contains wooden studs, dead center of the wooden stud must be confirmed prior to installation.
Do not install on a structure that is prone to vibration, movement or chance of impact. Failure to do so could result in damage to the display and/or damage to the mounting surface.
Do not install near heater, fireplace, direct sunlight, air conditioning or any other source of direct heat energy. Failure to do so may result in damage to the display and could increase the risk of fire.
At least two qualified people should perform the installation procedure. Injury and/or damage can result from dropping or mishandling the display.
Recommended mounting surfaces: wooden studs and solid-flat concrete. If the mount is to be installed on any surface other than wooden studs, use suitable hardware (which is commercially available).
Contact Orion Images with any technical/ installation questions.
Installation and User’s Guide
Warning Statements
3
7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310
pg3
(
http://www.orionimages.com
Installation and User’s Guide
Part List
NOTE
Installation Tools
Phillips Head Screw Driver, Soft Material/ Blanket, 5/16” Socket and Wrench Pencil Tape Measure, Drill Gun,
This wall mount is shipped with all proper installation hardware and components. Make sure that none of these parts are missing and/or damaged before beginning installation. If there are parts missing and/or damaged, please stop the installation and contact Orion Images.
-
-
WB-71 Wall Plate (1ea)
5/16” Flat Washers (12ea)
M6 x 30mm Lateral Shift Locking Screws (2ea)
M6 x 12mm Safety Knobs (2ea)
Mounting Brackets
5/16” x 3” Lag Bolts (wooden studs only) – (12ea)
2ea)
Griplates™ (8ea)
Thread Depth Indicator
4
7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310
pg4
http://www.orionimages.com
Installation and User’s Guide
5
7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310
pg5
http://www.orionimages.com
Nylon spacers and flat washers actual size
NOTE
The nylon spacers may be stacked to achieve proper spacing.
1/2" Nylon spacers (Qty 6) (large)
5/16" Flat washers (metal) (Qty 6)
1/4" Nylon spacers (Qty 6)
Installation and User’s Guide
6
7300 Bolsa Avenue, Westminster CA 92683 / Tel: 714-766-6300 / Fax: 714-766-6310
pg6