Orion OA92 Series Data Sheet

OOAA9922 SSeerriiees
s
AC Fan - 115V, 230V, Dual Voltage
92 x 25mm(3.62” x 1.0”)
Frame
Impeller
Connection
Motor
Bearing System
Insulation Resistance
Dielectric Strength
Model Number Speed (RPM) Airflow (CFM) Noise (dB) Volts AC
OA92AP-11-1* 3000 35 30 115 80~130 13 .20 OA92AP-11-2* 2300 27 22 115 80~130 10 .14 OA92AP-11-3* 1600 21 19 115 80~130 6 .09 OA92AP-22-1* 3000 35 30 230 160~260 13 .20 OA92AP-22-2* 2300 27 22 230 160~260 10 .14 OA92AP-22-3* 1600 21 19 230 160~260 6 .09
Diecast Aluminum
PBT, UL94V-O plastic
2x Lead Wires 22 AWG or terminals
Shaded pole, impedance and thermally protected
Dual ball or Sleeve
>100M ohm between lead­wire and frame (500VDC)
1 min at 1500 VAC, 50/60Hz
Operating Temperature Ball Bearing
-20C ~ +80C Sleeve Bearing
-10C ~ +50C
fe Expectancy
Li Ball Bearing 60,000 hours (L10 at 40C)
Sleeve Bearing
30,000 hours (L10 at 40C)
Dual Voltage Connection via 4x leads. Fans can be configured for 115V or 230V operation.
V
R
tage
ol
ange
Watts
Max. Static
essur
Pr
e (“H2O)
OA92AP-11/22-1W** 3000 35 30 115/230 80~260 13 .20 OA92AP-11/22-2W** 2300 27 22 115/230 80~260 10 .14 OA92AP-11/22-3W** 1600 21 19 115/230 80~260 6 .09
* Indicate “TB” (Terminal Ball Bearing), “WB” (12” Wire Leads, Ball Bearing), “TS” (Terminal, Sleeve Bearing), “WS” (12” Wire Leads, Sleeve Bearing)
** Indicate “B” (Ball Bearing) or “S” (Sleeve Bearing)
10557 Metric Drive
Dallas, Texas 75243
214-340-0265
RoHS Compliant
OrionFans.com
Information and data is subject to
change without prior notification.
Loading...