Orion OA119 Series Data Sheet

OOAA111199 SSeerriiees
Substitute "AP" with "AN" for natural sanded and milled finish.
s
AC Fan - 115V, 230V
127 x 38mm (5.0” x 1.5”)
Frame
Impeller
Connection
Motor
Bearing System
Insulation Resistance
Dielectric Strength
Model Number Speed (RPM) Airflow (CFM) Noise (dB) Volts AC
OA119AP-11-1* 3000 130 46 115 80~130 12 .24 OA119AP-11-2* 2300 95 37 115 80~130 9 .15 OA119AP-11-3* 1400 74 28 115 80~130 5 .10 OA119AP-22-1* 3000 130 46 230 160~260 12 .24 OA119AP-22-2* 2300 95 37 230 160~260 9 .15 OA119AP-22-3* 1400 74 28 230 160~260 5 .10
Diecast Aluminum
PBT, UL94V-O plastic
2x Lead Wires 22 AWG or terminals
Shaded pole, impedance and thermally protected Tachometer available (5VTTL), input 5 ~24V
Dual ball or Sleeve
>100M ohm between lead­wire and frame (500VDC)
1 min at 1500 VAC, 50/60Hz
Operating Temperature Ball Bearing
-20C ~ +80C Sleeve Bearing
-10C ~ +50C
fe Expectancy
Li Ball Bearing 60,000 hours (L10 at 40C)
Sleeve Bearing
30,000 hours (L10 at 40C)
oltage
Dual V Connection via 4x leads. Fans can be configured for 115V or 230V operation.
V
R
tage
ol
ange
Watts
Max. Static
essur
Pr
e (“H2O)
* Indicate “TB” (Terminal Ball Bearing), “WB” (12” Wire Leads, Ball Bearing), “TS” (Terminal, Sleeve Bearing), “WS” (12” Wire Leads, Sleeve Bearing)
10557 Metric Drive
Dallas, Texas 75243
214-340-0265
RoHS Compliant
OrionFans.com
Information and data is subject to
change without prior notification.