OOAA110099 SSeerriiees
Substitute "AP" with "AN" for natural sanded and milled finish
s
AC Fan - 115V, 230V, Dual Voltage
120x38mm (4.7”x 1.5”)
ame
Fr
Impeller
Connection
Motor
Bearing System
Insulation Resistance
Dielectric Strength
Model Number Speed (RPM) Airflow (CFM) Noise (dB) Volts AC Voltage Range Watts
OA109AP-11-1* 3000 110 37 115 80~130 15 .28
OA109AP-11-2* 2300 71 30 115 80~130 11 .24
OA109AP-11-3* 1600 51 25 115 80~130 8 .15
OA109AP-22-1* 3000 110 37 230 160~260 15 .28
OA109AP-22-2* 2300 71 30 230 160~260 11 .24
OA109AP-22-3* 1600 51 25 230 160~260 8 .15
Diecast Aluminum
PBT, UL94V-O plastic
2x 300mm Lead wires or
terminals
AC shaded pole, impedance
and thermally protected
Dual ball or Sleeve
10M ohm between leadwire
and frame (500VDC)
1 min at 1500 VAC, 50/60Hz
Operating Temperature
Ball Bearing
-20C ~ +80C
Sleeve Bearing
-10C ~ +50C
fe Expectancy
Li
Ball Bearing
60,000 hours (L10 at 40C)
Sleeve Bearing
30,000 hours (L10 at 40C)
oltage
Dual V
Fans can be configured to
run on 115V or 230V.
Connection via 4x leads
Max. Static
Pressure (“H2O)
OA109AP-11/22-1W** 3000 110 37 115/230 80~260 15 .28
OA109AP-11/22-2W** 2300 71 30 115/230 80~260 11 .24
OA109AP-11/22-3W** 1600 51 25 115/230 80~260 8 .15
* Indicate “TB” (Terminal Ball Bearing), “WB” (12” Wire Leads, Ball Bearing), “TS” (Terminal, Sleeve Bearing), “WS” (12” Wire Leads, Sleeve Bearing)
** Indicate “B” (Ball Bearing) or “S” (Sleeve Bearing)
10557 Metric Drive
Dallas, Texas 75243
214-340-0265
RoHS Compliant
OrionFans.com
Information and data is subject to
change without prior notification.